Journal article · 2020 · Open access

Microfluidic based Platform for drug screening-A review

Kalpana Seelam, Daisy Rani A

International Journal of Research in Pharmaceutical Sciences, 11(3), 2999–3004 · Published 6 July 2020 · DOI 10.26452/ijrps.v11i3.2394

Open full textCite this paper

In brief

“Microfluidic based Platform for drug screening-A review” is a 2020 journal article by Kalpana Seelam and Daisy Rani A, published in International Journal of Research in Pharmaceutical Sciences. OpenAlex counts 1 citations as of 19 November 2026. It is open access under a CC BY-NC-ND licence: the full text is free to read at International Journal of Research in Pharmaceutical Sciences.

Citations
1
Most cited in
2024 (1)
Authors
2

Abstract

There is a lot of requirement to develop a preclinical rapid drug screening devices to treat the throat cancerous patients in effective manner. Very High cost models like animal based, 2d and 3d type models are static drug screening models and they are unable to mimic the human body dynamic condition. So microfluidic platform based drug screening devices will give predetermined and prominent result in rapid drug screening by mimic dynamic body conditions. Now it is required to review what are the developments from last five years in screening the drug for cancer. Recently research is going on microfluidic platforms to screen the efficacy of mixed drugs, drug tolerance, and drug susceptibility. So this study presents the review on what are the advancements in microfluidic platforms for rapid drug screening and for different cancer patients. This study also presents what are the different sensing methodologies of microfluidic devices exists to screen the drug for various cancerous tissues

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Seelam, K., & A, D. R. (2020). Microfluidic based Platform for drug screening-A review. International Journal of Research in Pharmaceutical Sciences, 11(3), 2999–3004. https://doi.org/10.26452/ijrps.v11i3.2394

MLA 9

Seelam, Kalpana, and Daisy Rani A. “Microfluidic based Platform for drug screening-A review.” International Journal of Research in Pharmaceutical Sciences, vol. 11, no. 3, 2020, pp. 2999–3004. https://doi.org/10.26452/ijrps.v11i3.2394.

Chicago

Seelam, Kalpana and Daisy Rani A. 2020. “Microfluidic based Platform for drug screening-A review.” International Journal of Research in Pharmaceutical Sciences 11 (3): 2999–3004. https://doi.org/10.26452/ijrps.v11i3.2394.

Harvard

Seelam, K. and A, D. R. (2020) ‘Microfluidic based Platform for drug screening-A review’, International Journal of Research in Pharmaceutical Sciences, 11(3), pp. 2999–3004. doi:10.26452/ijrps.v11i3.2394.

IEEE

K. Seelam and D. R. A, “Microfluidic based Platform for drug screening-A review,” International Journal of Research in Pharmaceutical Sciences, vol. 11, no. 3, pp. 2999–3004, 2020, doi: 10.26452/ijrps.v11i3.2394.

BibTeX

@article{seelam2020microfluidic,
  title     = {{Microfluidic based Platform for drug screening-A review}},
  author    = {Seelam, Kalpana and A, Daisy Rani},
  journal   = {International Journal of Research in Pharmaceutical Sciences},
  year      = {2020},
  volume    = {11},
  number    = {3},
  pages     = {2999--3004},
  doi       = {10.26452/ijrps.v11i3.2394},
  url       = {https://doi.org/10.26452/ijrps.v11i3.2394}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications

  • throat cancer
  • anticancer drug screening
  • drug sensitivity
  • drug tolerance
  • drug combination screening
  • in vitro tumor model
  • microfluidic sensing
  • preclinical drug testing

Work with this paper

Most-cited papers in Engineering

All highly cited Engineering papers

Questions about this paper

How do I cite this paper in APA style?

Seelam, K., & A, D. R. (2020). Microfluidic based Platform for drug screening-A review. International Journal of Research in Pharmaceutical Sciences, 11(3), 2999–3004. https://doi.org/10.26452/ijrps.v11i3.2394

How many times has this paper been cited?

1 times, according to OpenAlex on 19 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at International Journal of Research in Pharmaceutical Sciences: sign in and open the full text from this page.

Who wrote this paper?

Kalpana Seelam, Daisy Rani A.

What is the DOI of this paper?

10.26452/ijrps.v11i3.2394, permanently at https://doi.org/10.26452/ijrps.v11i3.2394. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 19 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.