Conference paper · 2009
Micro artificial muscle fiber using NiTi spring for soft robotics
IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS), 2228–2234 · Published 1 October 2009 · DOI 10.1109/iros.2009.5354178
In brief
“Micro artificial muscle fiber using NiTi spring for soft robotics” is a 2009 conference paper by Sangbae Kim and 5 co-authors, published in IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS). OpenAlex counts 180 citations as of 22 November 2026, which puts it in the top 4% of works published in 2009 by citations. The publisher's version is not open access, and OpenAlex records no free legal copy.
- Citations
- 180
- Most cited in
- 2017 (20)
- Field-weighted impact
- 10.08
- References
- 9
- Authors
- 6
Abstract
For a new class of soft robotic platforms, development of flexible and robust actuators is quintessential. Remarkable resilience, shape memory effect, high energy density, and scalability are attributed to nickel titanium (NiTi) making it an excellent actuator candidate for meso-scale applications. This paper presents a micro-muscle fiber crafted from shape memory alloy (NiTi) coiled springs.… Read the full abstract at the publisher.
Excerpt. This paper is not open access.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Kim, S., Hawkes, E. W., Cho, K., Joldaz, M., Foleyz, J., & Wood, R. J. (2009). Micro artificial muscle fiber using NiTi spring for soft robotics. IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS), 2228–2234. https://doi.org/10.1109/iros.2009.5354178
MLA 9
Kim, Sangbae, et al. “Micro artificial muscle fiber using NiTi spring for soft robotics.” IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS), 2009, pp. 2228–2234. https://doi.org/10.1109/iros.2009.5354178.
Chicago
Kim, Sangbae, Elliot Wright Hawkes, Kyu‐Jin Cho, Matthew Joldaz, Joe Foleyz, and Robert J. Wood. 2009. “Micro artificial muscle fiber using NiTi spring for soft robotics.” IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS): 2228–2234. https://doi.org/10.1109/iros.2009.5354178.
Harvard
Kim, S. et al. (2009) ‘Micro artificial muscle fiber using NiTi spring for soft robotics’, IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS), pp. 2228–2234. doi:10.1109/iros.2009.5354178.
IEEE
S. Kim, E. W. Hawkes, K. Cho, M. Joldaz, J. Foleyz, and R. J. Wood, “Micro artificial muscle fiber using NiTi spring for soft robotics,” IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS), pp. 2228–2234, 2009, doi: 10.1109/iros.2009.5354178.
BibTeX
@inproceedings{kim2009micro,
title = {{Micro artificial muscle fiber using NiTi spring for soft robotics}},
author = {Kim, Sangbae and Hawkes, Elliot Wright and Cho, Kyu‐Jin and Joldaz, Matthew and Foleyz, Joe and Wood, Robert J.},
booktitle = {IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS)},
year = {2009},
pages = {2228--2234},
doi = {10.1109/iros.2009.5354178},
url = {https://doi.org/10.1109/iros.2009.5354178}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Citations by year
| Year | Citations | Share of the best year |
|---|---|---|
| 2017 | 20 | |
| 2018 | 14 | |
| 2019 | 12 | |
| 2020 | 15 | |
| 2021 | 9 | |
| 2022 | 10 | |
| 2023 | 8 | |
| 2024 | 12 | |
| 2025 | 4 | |
| 2026 | 4 |
Its field-weighted citation impact is 10.08: it has been cited 10.08 times as often as the average work of the same field, type and year (1.00 is the world average).
Topic and keywords
Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- NiTi
- shape memory alloys
- microactuators
- coiled springs
- soft robotics
- energy density
- annealing temperature
- force-displacement characteristics
Work with this paper
Most-cited papers in Engineering
- A Closed‐form Equation for Predicting the Hydraulic Conductivity of Unsaturated SoilsMartinus Th. van Genuchten · Soil Science Society of America Journal · 1980 · 28,197 citations
- An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experimentsW. C. Oliver, George M. Pharr · Journal of materials research/Pratt's guide to venture capital sources · 1992 · 27,379 citations
- Digital communicationsOwen Bishop · Routledge eBooks · 2007 · 24,890 citations
- The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysisNorden Eh Huang, Zhengwei Shen, Steven R. Long and 6 more · Proceedings of the Royal Society A Mathematical Physical and Engineering Sciences · 1998 · 24,008 citations
- Numerical Heat Transfer and Fluid FlowSuhas V. Patankar · CRC Press eBooks · 2018 · 23,491 citations
Questions about this paper
How do I cite this paper in APA style?
Kim, S., Hawkes, E. W., Cho, K., Joldaz, M., Foleyz, J., & Wood, R. J. (2009). Micro artificial muscle fiber using NiTi spring for soft robotics. IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS), 2228–2234. https://doi.org/10.1109/iros.2009.5354178
How many times has this paper been cited?
180 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
OpenAlex records no free legal copy. Check your library's access, the authors' pages or a repository, or ask the corresponding author for a copy.
Who wrote this paper?
Sangbae Kim, Elliot Wright Hawkes, Kyu‐Jin Cho, Matthew Joldaz, Joe Foleyz, Robert J. Wood.
What is the DOI of this paper?
10.1109/iros.2009.5354178, permanently at https://doi.org/10.1109/iros.2009.5354178. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.