Journal article · 2026 · Open access
Mechanism-dependent antagonism of auxiliary information in substation-level load disaggregation for distribution network planning
Applied Energy, 427, 129131 · Published 23 October 2026 · DOI 10.1016/j.apenergy.2026.129131
In brief
“Mechanism-dependent antagonism of auxiliary information in substation-level load disaggregation for distribution network planning” is a 2026 journal article by Xuanhao Mu and 5 co-authors, published in Applied Energy. OpenAlex counts 1 citations as of 18 November 2026. It is open access under a CC BY licence: the full text is free to read at Applied Energy.
- Citations
- 1
- Most cited in
- 2026 (1)
- Field-weighted impact
- 1.10
- References
- 38
- Authors
- 6
Abstract
Open-source energy system models disaggregate zonal electricity demand to substations, and modellers routinely layer auxiliary information onto that allocation, assuming more information cannot hurt. The pipeline gives no warning when it does. We fix the Voronoi assignment and test 22 configurations crossing uniform, Grid Point Model (GPM), and graph neural network (GNN) weighting with post-correction, prior-loss, and feature-fusion integration on 1891 British, 143 Australian, and 13 German substations, with Germany descriptive. At unit correction intensity ( β = 1 ), Nighttime Light and Proximity cut RMSE by 37–43% on the tested uniform and GPM bases, raise the British GNN value by 21%, and lower the Australian one by 30%. Absolute accuracy is study-case- and estimand-dependent: pooled predictive R 2 is positive for selected British configurations, whereas region-mean predictive R 2 is negative for all 22 configurations and for the pipeline-matched grid reference in both main study cases. Under geometric re-normalization and log-MSE, correction helps exactly when factor–residual alignment exceeds half the factor’s relative dispersion. In the implemented pipeline it classifies original-scale RMSE direction in 391 / 435 configurations ( 89.9 % , against a 74.7 % majority-class base rate), rising to 97.0 % outside the displacement band and 67.3 % inside. We derive the mapping from grid-point correction to the criterion’s substation factor. The condition characterizes error direction, not magnitude, and evaluating factor–residual alignment and residual dispersion requires metered substation demand; it informs integration-mechanism trade-offs, not absolute accuracy or downstream planning decisions. Code is available at https://github.com/KIT-IAI/AllocateGNN
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Mu, X., Thota, K. S. P., Liu, N., Liu, J., Schlachter, T., & Hagenmeyer, V. (2026). Mechanism-dependent antagonism of auxiliary information in substation-level load disaggregation for distribution network planning. Applied Energy, 427, 129131. https://doi.org/10.1016/j.apenergy.2026.129131
MLA 9
Mu, Xuanhao, et al. “Mechanism-dependent antagonism of auxiliary information in substation-level load disaggregation for distribution network planning.” Applied Energy, vol. 427, 2026, p. 129131. https://doi.org/10.1016/j.apenergy.2026.129131.
Chicago
Mu, Xuanhao, Kundan Sai Prabhu Thota, Nan Liu, Jianlei Liu, Thorsten Schlachter, and Veit Hagenmeyer. 2026. “Mechanism-dependent antagonism of auxiliary information in substation-level load disaggregation for distribution network planning.” Applied Energy 427: 129131. https://doi.org/10.1016/j.apenergy.2026.129131.
Harvard
Mu, X. et al. (2026) ‘Mechanism-dependent antagonism of auxiliary information in substation-level load disaggregation for distribution network planning’, Applied Energy, 427, p. 129131. doi:10.1016/j.apenergy.2026.129131.
IEEE
X. Mu, K. S. P. Thota, N. Liu, J. Liu, T. Schlachter, and V. Hagenmeyer, “Mechanism-dependent antagonism of auxiliary information in substation-level load disaggregation for distribution network planning,” Applied Energy, vol. 427, p. 129131, 2026, doi: 10.1016/j.apenergy.2026.129131.
BibTeX
@article{mu2026mechanism,
title = {{Mechanism-dependent antagonism of auxiliary information in substation-level load disaggregation for distribution network planning}},
author = {Mu, Xuanhao and Thota, Kundan Sai Prabhu and Liu, Nan and Liu, Jianlei and Schlachter, Thorsten and Hagenmeyer, Veit},
journal = {Applied Energy},
year = {2026},
volume = {427},
pages = {129131},
doi = {10.1016/j.apenergy.2026.129131},
url = {https://doi.org/10.1016/j.apenergy.2026.129131}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Topic and keywords
Physical Sciences › Engineering › Electrical and Electronic Engineering › Energy Load and Power Forecasting
- load disaggregation
- distribution network planning
- graph neural networks
- nighttime lights
- proximity correction
- feature fusion
- energy system modelling
Work with this paper
Most-cited papers in Engineering
- A Closed‐form Equation for Predicting the Hydraulic Conductivity of Unsaturated SoilsMartinus Th. van Genuchten · Soil Science Society of America Journal · 1980 · 28,197 citations
- An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experimentsW. C. Oliver, George M. Pharr · Journal of materials research/Pratt's guide to venture capital sources · 1992 · 27,379 citations
- Digital communicationsOwen Bishop · Routledge eBooks · 2007 · 24,890 citations
- The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysisNorden Eh Huang, Zhengwei Shen, Steven R. Long and 6 more · Proceedings of the Royal Society A Mathematical Physical and Engineering Sciences · 1998 · 24,008 citations
- Numerical Heat Transfer and Fluid FlowSuhas V. Patankar · CRC Press eBooks · 2018 · 23,491 citations
Questions about this paper
How do I cite this paper in APA style?
Mu, X., Thota, K. S. P., Liu, N., Liu, J., Schlachter, T., & Hagenmeyer, V. (2026). Mechanism-dependent antagonism of auxiliary information in substation-level load disaggregation for distribution network planning. Applied Energy, 427, 129131. https://doi.org/10.1016/j.apenergy.2026.129131
How many times has this paper been cited?
1 times, according to OpenAlex on 18 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at Applied Energy: sign in and open the full text from this page.
Who wrote this paper?
Xuanhao Mu, Kundan Sai Prabhu Thota, Nan Liu, Jianlei Liu, Thorsten Schlachter, Veit Hagenmeyer.
What is the DOI of this paper?
10.1016/j.apenergy.2026.129131, permanently at https://doi.org/10.1016/j.apenergy.2026.129131. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 18 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.