Journal article · 2026 · Open access

Measurement fidelity and external validation of automated breast DCE-MRI segmentation

Chunlei Tan, Li Chen, Xu Jin, Jian Zheng, Shiyuan Zhang, 黄元夕

npj Digital Medicine · Published 14 November 2026 · DOI 10.1038/s41746-026-03446-z

Open PDFView at the publisherCite this paper

In brief

“Measurement fidelity and external validation of automated breast DCE-MRI segmentation” is a 2026 journal article by Chunlei Tan and 5 co-authors, published in npj Digital Medicine. OpenAlex counts 0 citations as of 18 November 2026. It is open access under a CC BY-NC-ND licence: the full text is free to read at npj Digital Medicine.

Citations
0
References
3
Authors
6

Abstract

Automated breast dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) segmentation could facilitate quantitative tumor measurement, but geometric overlap alone does not establish the fidelity of mask-derived measurements. We developed an enhancement-aware three-dimensional MedNeXt framework with gated skip fusion and boundary supervision and evaluated it in a retrospective multi-cohort design spanning locked internal testing, source-held-out assessment, retrospective external validation, and radiologist review. Measurement fidelity was the primary endpoint. Across 521 paired internal-test and DUKE cases, median errors were 9.7% for tumor volume, 1.8 mm for 3D maximum surface diameter, and 10.2% for operational enhancement-defined volume, with corresponding ICCs of 0.97, 0.80, and 0.97. Median Dice was 0.831 internally and 0.823 in the DUKE source-held-out stratum, and was 0.812 and 0.806 in the BC-MRI-SEG and public BreastDCEDL_AMBL retrospective external-validation cohorts, respectively, using the frozen checkpoint without external-label tuning. No major correction was required for 78 of 80 masks in the blinded two-reader review. In 276 paired response-analysis cases, AUROC was 0.732 with automatic geometry and 0.757 with expert geometry (difference, −0.025; 95% CI, −0.095 to 0.045); discrimination non-inferiority was not demonstrated. These findings support automated segmentation as a starting point for radiologist-supervised retrospective quantitative research within the evaluated cohorts, while distinguishing measurement fidelity from downstream predictive equivalence.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Tan, C., Chen, L., Jin, X., Zheng, J., Zhang, S., & 黄元夕. (2026). Measurement fidelity and external validation of automated breast DCE-MRI segmentation. npj Digital Medicine. https://doi.org/10.1038/s41746-026-03446-z

MLA 9

Tan, Chunlei, et al. “Measurement fidelity and external validation of automated breast DCE-MRI segmentation.” npj Digital Medicine, 2026. https://doi.org/10.1038/s41746-026-03446-z.

Chicago

Tan, Chunlei, Li Chen, Xu Jin, Jian Zheng, Shiyuan Zhang, and 黄元夕. 2026. “Measurement fidelity and external validation of automated breast DCE-MRI segmentation.” npj Digital Medicine. https://doi.org/10.1038/s41746-026-03446-z.

Harvard

Tan, C. et al. (2026) ‘Measurement fidelity and external validation of automated breast DCE-MRI segmentation’, npj Digital Medicine. doi:10.1038/s41746-026-03446-z.

IEEE

C. Tan, L. Chen, X. Jin, J. Zheng, S. Zhang, and 黄元夕, “Measurement fidelity and external validation of automated breast DCE-MRI segmentation,” npj Digital Medicine, 2026, doi: 10.1038/s41746-026-03446-z.

BibTeX

@article{tan2026measurement,
  title     = {{Measurement fidelity and external validation of automated breast DCE-MRI segmentation}},
  author    = {Tan, Chunlei and Chen, Li and Jin, Xu and Zheng, Jian and Zhang, Shiyuan and 黄元夕},
  journal   = {npj Digital Medicine},
  year      = {2026},
  doi       = {10.1038/s41746-026-03446-z},
  url       = {https://doi.org/10.1038/s41746-026-03446-z}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques

  • dynamic contrast-enhanced MRI
  • breast cancer
  • measurement fidelity
  • external validation
  • boundary supervision
  • tumor volume

Work with this paper

Most-cited papers in Computer Science

All highly cited Computer Science papers

Questions about this paper

How do I cite this paper in APA style?

Tan, C., Chen, L., Jin, X., Zheng, J., Zhang, S., & 黄元夕. (2026). Measurement fidelity and external validation of automated breast DCE-MRI segmentation. npj Digital Medicine. https://doi.org/10.1038/s41746-026-03446-z

How many times has this paper been cited?

0 times, according to OpenAlex on 18 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at npj Digital Medicine: sign in and open the PDF from this page.

Who wrote this paper?

Chunlei Tan, Li Chen, Xu Jin, Jian Zheng, Shiyuan Zhang, 黄元夕.

What is the DOI of this paper?

10.1038/s41746-026-03446-z, permanently at https://doi.org/10.1038/s41746-026-03446-z. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 18 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.