Journal article · 2026 · Open access

Measure the Ward First: Intentional Sufficiency as a Design Rule for Sleep Sensing in Acute Inpatient Psychiatry

Hong-Ming Chen, Terry B. J. Kuo

Journal of Medical Internet Research, 28, e112674 · Published 19 November 2026 · DOI 10.2196/112674

Open full textCite this paper

In brief

“Measure the Ward First: Intentional Sufficiency as a Design Rule for Sleep Sensing in Acute Inpatient Psychiatry” is a 2026 journal article by Hong-Ming Chen and Terry B. J. Kuo, published in Journal of Medical Internet Research. OpenAlex counts 0 citations as of 25 November 2026. It is open access under a CC BY licence: the full text is free to read at Journal of Medical Internet Research.

Citations
0
References
25
Authors
2

Abstract

This Viewpoint argues that measurement design, not model capability, is the first constraint on clinical AI in acute inpatient psychiatry and proposes intentional sufficiency as a design rule for sleep sensing on acute wards. Acute psychiatric wards exclude much of the conventional sensing design space: ligature, ingestion, and projectile hazards; unreliable adherence; impaired consent; and nursing workload mean that a device that is excellent when a patient is cooperative may be absent when the patient is most unwell. We define intentional sufficiency in 3 parts: the intended clinical use sets the required signal properties and acceptable error; safety, validity, consent, and workflow constraints define the feasible design space; and within that space, the rule selects the least burdensome option that preserves the required properties, because excess capability can be paid for in persistence, not only in money. We contrast this rule with capability-maximizing design using 2 examples at opposite ends of the design space: a structured nightly nursing sleep duration record that, in Taiwan, already exists within routine care, and a disposable wrist-worn sensing architecture under development that reduces the wearable to what the derived sleep measure requires. The first shows when the rule can conclude that no hardware should be added, provided adequacy has been shown for the intended use; the second shows when it concludes that hardware must be redesigned, and is presented as a design prediction rather than a result. Importantly, agreement with a reference method does not by itself establish task-level sufficiency; greater sensing capability does not necessarily produce more clinically available information when deployment and persistence are constrained; and some signal properties are validity defining and cannot be traded against cost.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Chen, H.-M., & Kuo, T. B. J. (2026). Measure the Ward First: Intentional Sufficiency as a Design Rule for Sleep Sensing in Acute Inpatient Psychiatry. Journal of Medical Internet Research, 28, e112674. https://doi.org/10.2196/112674

MLA 9

Chen, Hong-Ming, and Terry B. J. Kuo. “Measure the Ward First: Intentional Sufficiency as a Design Rule for Sleep Sensing in Acute Inpatient Psychiatry.” Journal of Medical Internet Research, vol. 28, 2026, p. e112674. https://doi.org/10.2196/112674.

Chicago

Chen, Hong-Ming and Terry B. J. Kuo. 2026. “Measure the Ward First: Intentional Sufficiency as a Design Rule for Sleep Sensing in Acute Inpatient Psychiatry.” Journal of Medical Internet Research 28: e112674. https://doi.org/10.2196/112674.

Harvard

Chen, H.-M. and Kuo, T. B. J. (2026) ‘Measure the Ward First: Intentional Sufficiency as a Design Rule for Sleep Sensing in Acute Inpatient Psychiatry’, Journal of Medical Internet Research, 28, p. e112674. doi:10.2196/112674.

IEEE

H.-M. Chen and T. B. J. Kuo, “Measure the Ward First: Intentional Sufficiency as a Design Rule for Sleep Sensing in Acute Inpatient Psychiatry,” Journal of Medical Internet Research, vol. 28, p. e112674, 2026, doi: 10.2196/112674.

BibTeX

@article{chen2026measure,
  title     = {{Measure the Ward First: Intentional Sufficiency as a Design Rule for Sleep Sensing in Acute Inpatient Psychiatry}},
  author    = {Chen, Hong-Ming and Kuo, Terry B. J.},
  journal   = {Journal of Medical Internet Research},
  year      = {2026},
  volume    = {28},
  pages     = {e112674},
  doi       = {10.2196/112674},
  url       = {https://doi.org/10.2196/112674}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Health Sciences › Medicine › Health Informatics › Healthcare Technology and Patient Monitoring

  • acute psychiatric wards
  • wearable sensors
  • wrist-worn devices
  • measurement design
  • patient consent
  • nursing workload
  • psychiatric inpatient care

Work with this paper

Most-cited papers in Medicine

All highly cited Medicine papers

Questions about this paper

How do I cite this paper in APA style?

Chen, H.-M., & Kuo, T. B. J. (2026). Measure the Ward First: Intentional Sufficiency as a Design Rule for Sleep Sensing in Acute Inpatient Psychiatry. Journal of Medical Internet Research, 28, e112674. https://doi.org/10.2196/112674

How many times has this paper been cited?

0 times, according to OpenAlex on 25 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Journal of Medical Internet Research: sign in and open the full text from this page.

Who wrote this paper?

Hong-Ming Chen, Terry B. J. Kuo.

What is the DOI of this paper?

10.2196/112674, permanently at https://doi.org/10.2196/112674. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 25 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.