“Maximum-entropy-method analysis of neutron diffraction data” is a 1993 journal article by M. Sakata and 3 co-authors, published in Journal of Applied Crystallography. OpenAlex counts 76 citations as of 23 November 2026. The publisher's version is not open access, and OpenAlex records no free legal copy.
- Citations
- 76
- Most cited in
- 2015 (3)
- Field-weighted impact
- 3.16
- Authors
- 4
Abstract
The maximum-entropy method (MEM) is a very powerful method for deriving accurate electron-density distributions from X-ray diffraction data. The success of the method depends on the fact that the electron density is always positive. In order to analyse neutron diffraction data by the MEM, it is necessary to overcome the difficulty of negative scattering lengths… Read the full abstract at the publisher.
Excerpt. This paper is not open access.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Sakata, M., Uno, T., Takata, M., & Howard, C. J. (1993). Maximum-entropy-method analysis of neutron diffraction data. Journal of Applied Crystallography, 26(2), 159–165. https://doi.org/10.1107/s0021889892010793
MLA 9
Sakata, M., et al. “Maximum-entropy-method analysis of neutron diffraction data.” Journal of Applied Crystallography, vol. 26, no. 2, 1993, pp. 159–165. https://doi.org/10.1107/s0021889892010793.
Chicago
Sakata, M., T. Uno, Masaki Takata, and Christopher J. Howard. 1993. “Maximum-entropy-method analysis of neutron diffraction data.” Journal of Applied Crystallography 26 (2): 159–165. https://doi.org/10.1107/s0021889892010793.
Harvard
Sakata, M. et al. (1993) ‘Maximum-entropy-method analysis of neutron diffraction data’, Journal of Applied Crystallography, 26(2), pp. 159–165. doi:10.1107/s0021889892010793.
IEEE
M. Sakata, T. Uno, M. Takata, and C. J. Howard, “Maximum-entropy-method analysis of neutron diffraction data,” Journal of Applied Crystallography, vol. 26, no. 2, pp. 159–165, 1993, doi: 10.1107/s0021889892010793.
BibTeX
@article{sakata1993maximum,
title = {{Maximum-entropy-method analysis of neutron diffraction data}},
author = {Sakata, M. and Uno, T. and Takata, Masaki and Howard, Christopher J.},
journal = {Journal of Applied Crystallography},
year = {1993},
volume = {26},
number = {2},
pages = {159--165},
doi = {10.1107/s0021889892010793},
url = {https://doi.org/10.1107/s0021889892010793}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Citations by year
| Year | Citations | Share of the best year |
|---|---|---|
| 2014 | 1 | |
| 2015 | 3 | |
| 2017 | 3 | |
| 2018 | 3 | |
| 2019 | 3 | |
| 2020 | 1 | |
| 2022 | 2 | |
| 2023 | 1 | |
| 2024 | 2 | |
| 2026 | 3 |
Its field-weighted citation impact is 3.16: it has been cited 3.16 times as often as the average work of the same field, type and year (1.00 is the world average).
Topic and keywords
Physical Sciences › Materials Science › Materials Chemistry › X-ray Diffraction in Crystallography
- maximum entropy method
- neutron powder diffraction
- electron density distribution
- scattering length density
- negative scattering length
- rutile
- titanium
- oxygen
Work with this paper
Most-cited papers in Materials Science
- Electric Field Effect in Atomically Thin Carbon FilmsKostya S. Novoselov, Andre K. Geim, Sergey V. Morozov and 5 more · Science · 2004 · 67,474 citations
- Revised effective ionic radii and systematic studies of interatomic distances in halides and chalcogenidesROBERT D. SHANNON · Acta Crystallographica Section A · 1976 · 66,944 citations
- Ab initio molecular dynamics for liquid metalsGeorg Kresse, J. Häfner · Physical review. B, Condensed matter · 1993 · 46,320 citations
- Helical microtubules of graphitic carbonSumio Iijima · Nature · 1991 · 43,639 citations
- The rise of grapheneAndre K. Geim, Kostya S. Novoselov · Nature Materials · 2007 · 40,328 citations
Questions about this paper
How do I cite this paper in APA style?
Sakata, M., Uno, T., Takata, M., & Howard, C. J. (1993). Maximum-entropy-method analysis of neutron diffraction data. Journal of Applied Crystallography, 26(2), 159–165. https://doi.org/10.1107/s0021889892010793
How many times has this paper been cited?
76 times, according to OpenAlex on 23 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
OpenAlex records no free legal copy. Check your library's access, the authors' pages or a repository, or ask the corresponding author for a copy.
Who wrote this paper?
M. Sakata, T. Uno, Masaki Takata, Christopher J. Howard.
What is the DOI of this paper?
10.1107/s0021889892010793, permanently at https://doi.org/10.1107/s0021889892010793. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 23 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.