Conference paper · 1994

Localized Cathodic Protection of Simulated Prestressed Concrete Pilings in Sea Water

William H. Hartt, Olivier Chaix, Richand J. Kessler, Rodney G. Powers

NACE CORROSION Conference, 1–21 · Published 27 February 1994 · DOI 10.5006/c1994-94291

View at the publisherCite this paper

In brief

“Localized Cathodic Protection of Simulated Prestressed Concrete Pilings in Sea Water” is a 1994 conference paper by William H. Hartt and 3 co-authors, published in NACE CORROSION Conference. OpenAlex counts 4 citations as of 22 November 2026. The publisher's version is not open access, and OpenAlex records no free legal copy.

Citations
4
Field-weighted impact
7.06
References
15
Authors
4

Abstract

Corrosion induced deterioration of prestressed concrete pilings in sea water has been established as the predominant failure mode for bridge structures in coastal Florida waters, and a technology involving localized impressed current cathodic protection of the splash zone region in association with conductive rubber anodes has been developed to mitigate this. In the present research… Read the full abstract at the publisher.

Excerpt. This paper is not open access.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Hartt, W. H., Chaix, O., Kessler, R. J., & Powers, R. G. (1994). Localized Cathodic Protection of Simulated Prestressed Concrete Pilings in Sea Water. NACE CORROSION Conference, 1–21. https://doi.org/10.5006/c1994-94291

MLA 9

Hartt, William H., et al. “Localized Cathodic Protection of Simulated Prestressed Concrete Pilings in Sea Water.” NACE CORROSION Conference, 1994, pp. 1–21. https://doi.org/10.5006/c1994-94291.

Chicago

Hartt, William H., Olivier Chaix, Richand J. Kessler, and Rodney G. Powers. 1994. “Localized Cathodic Protection of Simulated Prestressed Concrete Pilings in Sea Water.” NACE CORROSION Conference: 1–21. https://doi.org/10.5006/c1994-94291.

Harvard

Hartt, W. H. et al. (1994) ‘Localized Cathodic Protection of Simulated Prestressed Concrete Pilings in Sea Water’, NACE CORROSION Conference, pp. 1–21. doi:10.5006/c1994-94291.

IEEE

W. H. Hartt, O. Chaix, R. J. Kessler, and R. G. Powers, “Localized Cathodic Protection of Simulated Prestressed Concrete Pilings in Sea Water,” NACE CORROSION Conference, pp. 1–21, 1994, doi: 10.5006/c1994-94291.

BibTeX

@inproceedings{hartt1994localized,
  title     = {{Localized Cathodic Protection of Simulated Prestressed Concrete Pilings in Sea Water}},
  author    = {Hartt, William H. and Chaix, Olivier and Kessler, Richand J. and Powers, Rodney G.},
  booktitle = {NACE CORROSION Conference},
  year      = {1994},
  pages     = {1--21},
  doi       = {10.5006/c1994-94291},
  url       = {https://doi.org/10.5006/c1994-94291}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Physical Sciences › Engineering › Civil and Structural Engineering › Concrete Corrosion and Durability

  • impressed current cathodic protection
  • splash zone corrosion
  • seawater corrosion
  • depolarization
  • concrete moisture content
  • water level effects

Work with this paper

Most-cited papers in Engineering

All highly cited Engineering papers

Questions about this paper

How do I cite this paper in APA style?

Hartt, W. H., Chaix, O., Kessler, R. J., & Powers, R. G. (1994). Localized Cathodic Protection of Simulated Prestressed Concrete Pilings in Sea Water. NACE CORROSION Conference, 1–21. https://doi.org/10.5006/c1994-94291

How many times has this paper been cited?

4 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

OpenAlex records no free legal copy. Check your library's access, the authors' pages or a repository, or ask the corresponding author for a copy.

Who wrote this paper?

William H. Hartt, Olivier Chaix, Richand J. Kessler, Rodney G. Powers.

What is the DOI of this paper?

10.5006/c1994-94291, permanently at https://doi.org/10.5006/c1994-94291. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.