Journal article · 2015 · Open access

Laminar mixing in a SMX static mixer evaluated by positron emission particle tracking (PEPT) and magnetic resonance imaging (MRI)

Olga Mihailova, Victor Lim, Michael J. McCarthy, Kathryn L. McCarthy, Serafim Bakalis

Chemical Engineering Science, 137, 1014–1023 · Published 30 July 2015 · DOI 10.1016/j.ces.2015.07.015

Open PDFView at the publisherCite this paper

In brief

“Laminar mixing in a SMX static mixer evaluated by positron emission particle tracking (PEPT) and magnetic resonance imaging (MRI)” is a 2015 journal article by Olga Mihailova and 4 co-authors, published in Chemical Engineering Science. OpenAlex counts 53 citations as of 19 November 2026. It is open access under a CC BY licence: the full text is free to read at Chemical Engineering Science.

Citations
53
Most cited in
2017 (7)
Field-weighted impact
2.56
References
35
Authors
5

Abstract

Static mixers are implemented across many industries and are used for mixing, heating and reacting processes. This paper reports the combined use of positron emission particle tracking (PEPT) and magnetic resonance imaging (MRI) to assess mixing in the industrially important SMX static mixer geometry. The focus of this study was distributive mixing for a Newtonian fluid, glycerol, flowing in the laminar regime in the standard SMX static mixer. By implementing PEPT and MRI techniques, the work elucidated mixing indices that incorporate both local velocities and concentration fields within the structure of the mixer element at 0.5 mm intervals over a length of nine 1.0L/D SMX elements. The experimental results are placed in context with previously published computational studies for this geometry.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Mihailova, O., Lim, V., McCarthy, M. J., McCarthy, K. L., & Bakalis, S. (2015). Laminar mixing in a SMX static mixer evaluated by positron emission particle tracking (PEPT) and magnetic resonance imaging (MRI). Chemical Engineering Science, 137, 1014–1023. https://doi.org/10.1016/j.ces.2015.07.015

MLA 9

Mihailova, Olga, et al. “Laminar mixing in a SMX static mixer evaluated by positron emission particle tracking (PEPT) and magnetic resonance imaging (MRI).” Chemical Engineering Science, vol. 137, 2015, pp. 1014–1023. https://doi.org/10.1016/j.ces.2015.07.015.

Chicago

Mihailova, Olga, Victor Lim, Michael J. McCarthy, Kathryn L. McCarthy, and Serafim Bakalis. 2015. “Laminar mixing in a SMX static mixer evaluated by positron emission particle tracking (PEPT) and magnetic resonance imaging (MRI).” Chemical Engineering Science 137: 1014–1023. https://doi.org/10.1016/j.ces.2015.07.015.

Harvard

Mihailova, O. et al. (2015) ‘Laminar mixing in a SMX static mixer evaluated by positron emission particle tracking (PEPT) and magnetic resonance imaging (MRI)’, Chemical Engineering Science, 137, pp. 1014–1023. doi:10.1016/j.ces.2015.07.015.

IEEE

O. Mihailova, V. Lim, M. J. McCarthy, K. L. McCarthy, and S. Bakalis, “Laminar mixing in a SMX static mixer evaluated by positron emission particle tracking (PEPT) and magnetic resonance imaging (MRI),” Chemical Engineering Science, vol. 137, pp. 1014–1023, 2015, doi: 10.1016/j.ces.2015.07.015.

BibTeX

@article{mihailova2015laminar,
  title     = {{Laminar mixing in a SMX static mixer evaluated by positron emission particle tracking (PEPT) and magnetic resonance imaging (MRI)}},
  author    = {Mihailova, Olga and Lim, Victor and McCarthy, Michael J. and McCarthy, Kathryn L. and Bakalis, Serafim},
  journal   = {Chemical Engineering Science},
  year      = {2015},
  volume    = {137},
  pages     = {1014--1023},
  doi       = {10.1016/j.ces.2015.07.015},
  url       = {https://doi.org/10.1016/j.ces.2015.07.015}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
201777
201877
201944
202044
202144
202222
202366
202477
202566
202611

Its field-weighted citation impact is 2.56: it has been cited 2.56 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Fluid Dynamics and Mixing

  • static mixer
  • laminar mixing
  • distributive mixing
  • positron emission particle tracking
  • magnetic resonance imaging
  • glycerol
  • Newtonian fluid

Work with this paper

Most-cited papers in Chemical Engineering

All highly cited Chemical Engineering papers

Questions about this paper

How do I cite this paper in APA style?

Mihailova, O., Lim, V., McCarthy, M. J., McCarthy, K. L., & Bakalis, S. (2015). Laminar mixing in a SMX static mixer evaluated by positron emission particle tracking (PEPT) and magnetic resonance imaging (MRI). Chemical Engineering Science, 137, 1014–1023. https://doi.org/10.1016/j.ces.2015.07.015

How many times has this paper been cited?

53 times, according to OpenAlex on 19 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Chemical Engineering Science: sign in and open the PDF from this page.

Who wrote this paper?

Olga Mihailova, Victor Lim, Michael J. McCarthy, Kathryn L. McCarthy, Serafim Bakalis.

What is the DOI of this paper?

10.1016/j.ces.2015.07.015, permanently at https://doi.org/10.1016/j.ces.2015.07.015. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 19 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.