Journal article · 2018 · Open access
Is Oxygen Uptake Measurement Enough to Estimate Energy Expenditure During High-Intensity Intermittent Exercise? Quantification of Anaerobic Contribution by Different Methods
Frontiers in Physiology, 9, 868 · Published 9 July 2018 · DOI 10.3389/fphys.2018.00868
In brief
“Is Oxygen Uptake Measurement Enough to Estimate Energy Expenditure During High-Intensity Intermittent Exercise? Quantification of Anaerobic Contribution by Different Methods” is a 2018 journal article by Valéria Leme Gonçalves Panissa and 6 co-authors, published in Frontiers in Physiology. OpenAlex counts 72 citations as of 26 November 2026. It is open access under a CC BY licence: the full text is free to read at Frontiers in Physiology.
- Citations
- 72
- Most cited in
- 2024 (18)
- Field-weighted impact
- 3.15
- References
- 48
- Authors
- 7
Abstract
Purpose: The aim of the present study was to compare the contributions of the anaerobic pathway as determined by two different methods and energy expenditure during a typical high-intensity intermittent exercise (HIIE) protocol. Methods: A descriptive research design was utilized in which thirteen physically active men performed six experimental sessions consisting of an incremental test (session 1), submaximal tests at 40, 50, 60, 70, 75, 80, 85, 90% of velocity associated with maximum oxygen uptake (v V˙ O2max) with two intensities per session (sessions 2-5), and the HIIE protocol (session 6; 10 efforts of 1 min at v V˙ O2max interspersed by 1 min of passive recovery). The estimation of anaerobic energy system contribution was calculated by: (a) the excess post-exercise oxygen consumption plus delta lactate method and (b) the accumulated oxygen deficit method using the difference between predicted oxygen demand from the submaximal tests of varying intensities and accumulated oxygen uptake during HIIE. Estimation of aerobic energy system contribution was calculated through the measurement of oxygen consumption during activity. Total EE during the entire HIIE protocol (efforts + recovery) and for the efforts only were calculated from each method. Results: For efforts + recovery and efforts only, anaerobic contribution was similar for both methods, and consequently total EE was also equivalent (p = 0.230 for both comparisons). During efforts + recovery, aerobic:anaerobic energy system contribution was (68 ± 4%: 32 ± 4%), while efforts only was (54 ± 5%: 46 ± 5%) with both situations demonstrating greater aerobic than anaerobic contribution (p < 0.001 for both). Conclusion: Anaerobic contribution seems to be relevant during HIIE and must to be taken into account during total EE estimation; however, the type of method employed did not change the anaerobic contribution or total EE estimates.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Panissa, V. L. G., Fukuda, D. H., Caldeira, R. S., Gerosa-Neto, J., Lira, F. S., Zagatto, A. M., & Franchini, É. (2018). Is Oxygen Uptake Measurement Enough to Estimate Energy Expenditure During High-Intensity Intermittent Exercise? Quantification of Anaerobic Contribution by Different Methods. Frontiers in Physiology, 9, 868. https://doi.org/10.3389/fphys.2018.00868
MLA 9
Panissa, Valéria Leme Gonçalves, et al. “Is Oxygen Uptake Measurement Enough to Estimate Energy Expenditure During High-Intensity Intermittent Exercise? Quantification of Anaerobic Contribution by Different Methods.” Frontiers in Physiology, vol. 9, 2018, p. 868. https://doi.org/10.3389/fphys.2018.00868.
Chicago
Panissa, Valéria Leme Gonçalves, David Hideyoshi Fukuda, Renan Santos Caldeira, José Gerosa-Neto, Fábio Santos Lira, Alessandro Moura Zagatto, and Émerson Franchini. 2018. “Is Oxygen Uptake Measurement Enough to Estimate Energy Expenditure During High-Intensity Intermittent Exercise? Quantification of Anaerobic Contribution by Different Methods.” Frontiers in Physiology 9: 868. https://doi.org/10.3389/fphys.2018.00868.
Harvard
Panissa, V. L. G. et al. (2018) ‘Is Oxygen Uptake Measurement Enough to Estimate Energy Expenditure During High-Intensity Intermittent Exercise? Quantification of Anaerobic Contribution by Different Methods’, Frontiers in Physiology, 9, p. 868. doi:10.3389/fphys.2018.00868.
IEEE
V. L. G. Panissa et al., “Is Oxygen Uptake Measurement Enough to Estimate Energy Expenditure During High-Intensity Intermittent Exercise? Quantification of Anaerobic Contribution by Different Methods,” Frontiers in Physiology, vol. 9, p. 868, 2018, doi: 10.3389/fphys.2018.00868.
BibTeX
@article{panissa2018oxygen,
title = {{Is Oxygen Uptake Measurement Enough to Estimate Energy Expenditure During High-Intensity Intermittent Exercise? Quantification of Anaerobic Contribution by Different Methods}},
author = {Panissa, Valéria Leme Gonçalves and Fukuda, David Hideyoshi and Caldeira, Renan Santos and Gerosa-Neto, José and Lira, Fábio Santos and Zagatto, Alessandro Moura and Franchini, Émerson},
journal = {Frontiers in Physiology},
year = {2018},
volume = {9},
pages = {868},
doi = {10.3389/fphys.2018.00868},
url = {https://doi.org/10.3389/fphys.2018.00868}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Citations by year
| Year | Citations | Share of the best year |
|---|---|---|
| 2018 | 1 | |
| 2019 | 5 | |
| 2020 | 6 | |
| 2021 | 9 | |
| 2022 | 11 | |
| 2023 | 7 | |
| 2024 | 18 | |
| 2025 | 12 | |
| 2026 | 3 |
Its field-weighted citation impact is 3.15: it has been cited 3.15 times as often as the average work of the same field, type and year (1.00 is the world average).
Topic and keywords
Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- high-intensity intermittent exercise
- energy expenditure estimation
- oxygen consumption
- accumulated oxygen deficit
- excess post-exercise oxygen consumption
- submaximal exercise testing
- oxygen consumption measurement
Work with this paper
Most-cited papers in Medicine
- Yaşlı Kadınlarda Üreme SağlığıDemet Kokanalı, Yaprak Engin Üstün · Jinekoloji-Obstetrik ve Neonatoloji Tıp Dergisi · 2019 · 169,630 citations
- Global Cancer Statistics 2020: GLOBOCAN Estimates of Incidence and Mortality Worldwide for 36 Cancers in 185 CountriesHyuna Sung, Adalberto M. Filho, Mathieu Laversanne and 5 more · CA A Cancer Journal for Clinicians · 2021 · 119,885 citations
- “Mini-mental state”Marshal F. Folstein, Susan E. Folstein, Paul R. McHugh · Journal of Psychiatric Research · 1975 · 90,424 citations
- Global cancer statistics 2018: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countriesFreddie Bray, Jacques Ferlay, Isabelle Soerjomataram and 3 more · CA A Cancer Journal for Clinicians · 2018 · 87,396 citations
- Hallmarks of Cancer: The Next GenerationDouglas Hanahan, Robert A. Weinberg · Cell · 2011 · 69,758 citations
Questions about this paper
How do I cite this paper in APA style?
Panissa, V. L. G., Fukuda, D. H., Caldeira, R. S., Gerosa-Neto, J., Lira, F. S., Zagatto, A. M., & Franchini, É. (2018). Is Oxygen Uptake Measurement Enough to Estimate Energy Expenditure During High-Intensity Intermittent Exercise? Quantification of Anaerobic Contribution by Different Methods. Frontiers in Physiology, 9, 868. https://doi.org/10.3389/fphys.2018.00868
How many times has this paper been cited?
72 times, according to OpenAlex on 26 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at Frontiers in Physiology: sign in and open the PDF from this page.
Who wrote this paper?
Valéria Leme Gonçalves Panissa, David Hideyoshi Fukuda, Renan Santos Caldeira, José Gerosa-Neto, Fábio Santos Lira, Alessandro Moura Zagatto, Émerson Franchini.
What is the DOI of this paper?
10.3389/fphys.2018.00868, permanently at https://doi.org/10.3389/fphys.2018.00868. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 26 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.