Journal article · 2025 · Open access

Integrating AUROC and SSMD for quality control in high-throughput screening assays

Xiaohua Douglas Zhang

SLAS DISCOVERY, 36, 100269 · Published 3 September 2025 · DOI 10.1016/j.slasd.2025.100269

Free PDFView at the publisherCite this paper

In brief

“Integrating AUROC and SSMD for quality control in high-throughput screening assays” is a 2025 journal article by Xiaohua Douglas Zhang, published in SLAS DISCOVERY. OpenAlex counts 3 citations as of 15 November 2026, which puts it in the top 4% of works published in 2025 by citations. It is open access under a CC BY-NC-ND licence: the full text is free to read at SLAS DISCOVERY.

Citations
3
Most cited in
2026 (3)
Field-weighted impact
0.86
References
29
Authors
1

Abstract

High-throughput screening (HTS) assays are pivotal in modern biomedical research, particularly in drug discovery and functional genomics. Ensuring the quality and reliability of HTS data is critical, especially when dealing with the small sample sizes that are typical in such assays. This study explores the integration of two powerful statistical metrics-Strictly Standardized Mean Difference (SSMD) and Area Under the Receiver Operating Characteristic Curve (AUROC)-for quality control (QC) in HTS. SSMD offers a standardized, interpretable measure of effect size, while AUROC provides a threshold-independent assessment of discriminative power. By establishing the theoretical and empirical relationships between AUROC and SSMD, we demonstrate how these metrics complement each other and enhance QC practices. We provide parametric, semi-parametric, and non-parametric estimation methods, and demonstrate the utility of the integrated framework in real HTS datasets. Our findings support the joint application of SSMD and AUROC as a robust and interpretable approach to improving QC in HTS, particularly under constraints of limited sample sizes of positive and negative controls.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Zhang, X. D. (2025). Integrating AUROC and SSMD for quality control in high-throughput screening assays. SLAS DISCOVERY, 36, 100269. https://doi.org/10.1016/j.slasd.2025.100269

MLA 9

Zhang, Xiaohua Douglas. “Integrating AUROC and SSMD for quality control in high-throughput screening assays.” SLAS DISCOVERY, vol. 36, 2025, p. 100269. https://doi.org/10.1016/j.slasd.2025.100269.

Chicago

Zhang, Xiaohua Douglas. 2025. “Integrating AUROC and SSMD for quality control in high-throughput screening assays.” SLAS DISCOVERY 36: 100269. https://doi.org/10.1016/j.slasd.2025.100269.

Harvard

Zhang, X. D. (2025) ‘Integrating AUROC and SSMD for quality control in high-throughput screening assays’, SLAS DISCOVERY, 36, p. 100269. doi:10.1016/j.slasd.2025.100269.

IEEE

X. D. Zhang, “Integrating AUROC and SSMD for quality control in high-throughput screening assays,” SLAS DISCOVERY, vol. 36, p. 100269, 2025, doi: 10.1016/j.slasd.2025.100269.

BibTeX

@article{zhang2025integrating,
  title     = {{Integrating AUROC and SSMD for quality control in high-throughput screening assays}},
  author    = {Zhang, Xiaohua Douglas},
  journal   = {SLAS DISCOVERY},
  year      = {2025},
  volume    = {36},
  pages     = {100269},
  doi       = {10.1016/j.slasd.2025.100269},
  url       = {https://doi.org/10.1016/j.slasd.2025.100269}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Drug Discovery › Computational Drug Discovery Methods

  • high-throughput screening
  • quality control
  • area under the receiver operating characteristic
  • effect size
  • discriminatory power
  • small sample size
  • positive and negative controls
  • parameter estimation

Work with this paper

Most-cited papers in Pharmacology, Toxicology and Pharmaceutics

All highly cited Pharmacology, Toxicology and Pharmaceutics papers

Questions about this paper

How do I cite this paper in APA style?

Zhang, X. D. (2025). Integrating AUROC and SSMD for quality control in high-throughput screening assays. SLAS DISCOVERY, 36, 100269. https://doi.org/10.1016/j.slasd.2025.100269

How many times has this paper been cited?

3 times, according to OpenAlex on 15 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access: read the free full text at SLAS DISCOVERY.

Who wrote this paper?

Xiaohua Douglas Zhang.

What is the DOI of this paper?

10.1016/j.slasd.2025.100269. The permanent link is https://doi.org/10.1016/j.slasd.2025.100269.

Bibliographic data from OpenAlex (CC0), last checked 15 November 2026. ResearchGuru does not host this paper; the links go to the publisher or the repository that does.