Journal article · 2024 · Open access

Integrated Design and Fabrication of Pneumatic Soft Robot Actuators in a Single Casting Step

Afonso Silva, Diogo Fonseca, D.M. Neto, Mihail Babcinschi, Pedro Neto

Cyborg and Bionic Systems, 5, 0137 · Published 1 January 2024 · DOI 10.34133/cbsystems.0137

Open full textCite this paper

In brief

“Integrated Design and Fabrication of Pneumatic Soft Robot Actuators in a Single Casting Step” is a 2024 journal article by Afonso Silva and 4 co-authors, published in Cyborg and Bionic Systems. OpenAlex counts 46 citations as of 22 November 2026, which puts it in the top 5% of works published in 2024 by citations. It is open access under a CC BY licence: the full text is free to read at Cyborg and Bionic Systems.

Citations
46
Most cited in
2026 (28)
Field-weighted impact
3.87
References
71
Authors
5

Abstract

Bio-inspired soft robots have already shown the ability to handle uncertainty and adapt to unstructured environments. However, their availability is partially restricted by time-consuming, costly, and highly supervised design-fabrication processes, often based on resource-intensive iterative workflows. Here, we propose an integrated approach targeting the design and fabrication of pneumatic soft actuators in a single casting step. Molds and sacrificial water-soluble hollow cores are printed using fused filament fabrication. A heated water circuit accelerates the dissolution of the core's material and guarantees its complete removal from the actuator walls, while the actuator's mechanical operability is defined through finite element analysis. This enables the fabrication of actuators with non-uniform cross-sections under minimal supervision, thereby reducing the number of iterations necessary during the design and fabrication processes. Three actuators capable of bending and linear motion were designed, fabricated, integrated, and demonstrated as 3 different bio-inspired soft robots, an earthworm-inspired robot, a 4-legged robot, and a robotic gripper. We demonstrate the availability, versatility, and effectiveness of the proposed methods, contributing to accelerating the design and fabrication of soft robots. This study represents a step toward increasing the accessibility of soft robots to people at a lower cost.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Silva, A., Fonseca, D., Neto, D., Babcinschi, M., & Neto, P. (2024). Integrated Design and Fabrication of Pneumatic Soft Robot Actuators in a Single Casting Step. Cyborg and Bionic Systems, 5, 0137. https://doi.org/10.34133/cbsystems.0137

MLA 9

Silva, Afonso, et al. “Integrated Design and Fabrication of Pneumatic Soft Robot Actuators in a Single Casting Step.” Cyborg and Bionic Systems, vol. 5, 2024, p. 0137. https://doi.org/10.34133/cbsystems.0137.

Chicago

Silva, Afonso, Diogo Fonseca, D.M. Neto, Mihail Babcinschi, and Pedro Neto. 2024. “Integrated Design and Fabrication of Pneumatic Soft Robot Actuators in a Single Casting Step.” Cyborg and Bionic Systems 5: 0137. https://doi.org/10.34133/cbsystems.0137.

Harvard

Silva, A. et al. (2024) ‘Integrated Design and Fabrication of Pneumatic Soft Robot Actuators in a Single Casting Step’, Cyborg and Bionic Systems, 5, p. 0137. doi:10.34133/cbsystems.0137.

IEEE

A. Silva, D. Fonseca, D. Neto, M. Babcinschi, and P. Neto, “Integrated Design and Fabrication of Pneumatic Soft Robot Actuators in a Single Casting Step,” Cyborg and Bionic Systems, vol. 5, p. 0137, 2024, doi: 10.34133/cbsystems.0137.

BibTeX

@article{silva2024integrated,
  title     = {{Integrated Design and Fabrication of Pneumatic Soft Robot Actuators in a Single Casting Step}},
  author    = {Silva, Afonso and Fonseca, Diogo and Neto, D.M. and Babcinschi, Mihail and Neto, Pedro},
  journal   = {Cyborg and Bionic Systems},
  year      = {2024},
  volume    = {5},
  pages     = {0137},
  doi       = {10.34133/cbsystems.0137},
  url       = {https://doi.org/10.34133/cbsystems.0137}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
202433
20251515
20262828

Its field-weighted citation impact is 3.87: it has been cited 3.87 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications

  • soft robots
  • pneumatic actuators
  • fused deposition modeling
  • molds
  • biomimetic robots
  • robotic gripper
  • finite element analysis

Work with this paper

Most-cited papers in Engineering

All highly cited Engineering papers

Questions about this paper

How do I cite this paper in APA style?

Silva, A., Fonseca, D., Neto, D., Babcinschi, M., & Neto, P. (2024). Integrated Design and Fabrication of Pneumatic Soft Robot Actuators in a Single Casting Step. Cyborg and Bionic Systems, 5, 0137. https://doi.org/10.34133/cbsystems.0137

How many times has this paper been cited?

46 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Cyborg and Bionic Systems: sign in and open the full text from this page.

Who wrote this paper?

Afonso Silva, Diogo Fonseca, D.M. Neto, Mihail Babcinschi, Pedro Neto.

What is the DOI of this paper?

10.34133/cbsystems.0137, permanently at https://doi.org/10.34133/cbsystems.0137. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.