In brief

“In Vitro Microfluidic Models for Neurodegenerative Disorders” is a 2017 review article by Tatsuya Osaki and 4 co-authors, published in Advanced Healthcare Materials. OpenAlex counts 166 citations as of 27 November 2026, which puts it in the top 1% of works published in 2017 by citations. It is open access: the full text is free to read at PORTO@Iris.

Citations
166
Most cited in
2024 (29)
Field-weighted impact
0.99
References
287
Authors
5

Abstract

Microfluidic devices enable novel means of emulating neurodegenerative disease pathophysiology in vitro. These organ-on-a-chip systems can potentially reduce animal testing and substitute (or augment) simple 2D culture systems. Reconstituting critical features of neurodegenerative diseases in a biomimetic system using microfluidics can thereby accelerate drug discovery and improve our understanding of the mechanisms of several currently incurable diseases. This review describes latest advances in modeling neurodegenerative diseases in the central nervous system and the peripheral nervous system. First, this study summarizes fundamental advantages of microfluidic devices in the creation of compartmentalized cell culture microenvironments for the co-culture of neurons, glial cells, endothelial cells, and skeletal muscle cells and in their recapitulation of spatiotemporal chemical gradients and mechanical microenvironments. Then, this reviews neurodegenerative-disease-on-a-chip models focusing on Alzheimer's disease, Parkinson's disease, and amyotrophic lateral sclerosis. Finally, this study discusses about current drawbacks of these models and strategies that may overcome them. These organ-on-chip technologies can be useful to be the first line of testing line in drug development and toxicology studies, which can contribute significantly to minimize the phase of animal testing steps.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Osaki, T., Shin, Y., Sivathanu, V., Campisi, M., & Kamm, R. D. (2017). In Vitro Microfluidic Models for Neurodegenerative Disorders. Advanced Healthcare Materials, 7(2), 1700489. https://doi.org/10.1002/adhm.201700489

MLA 9

Osaki, Tatsuya, et al. “In Vitro Microfluidic Models for Neurodegenerative Disorders.” Advanced Healthcare Materials, vol. 7, no. 2, 2017, p. 1700489. https://doi.org/10.1002/adhm.201700489.

Chicago

Osaki, Tatsuya, Yoojin Shin, Vivek Sivathanu, Marco Campisi, and Roger Dale Kamm. 2017. “In Vitro Microfluidic Models for Neurodegenerative Disorders.” Advanced Healthcare Materials 7 (2): 1700489. https://doi.org/10.1002/adhm.201700489.

Harvard

Osaki, T. et al. (2017) ‘In Vitro Microfluidic Models for Neurodegenerative Disorders’, Advanced Healthcare Materials, 7(2), p. 1700489. doi:10.1002/adhm.201700489.

IEEE

T. Osaki, Y. Shin, V. Sivathanu, M. Campisi, and R. D. Kamm, “In Vitro Microfluidic Models for Neurodegenerative Disorders,” Advanced Healthcare Materials, vol. 7, no. 2, p. 1700489, 2017, doi: 10.1002/adhm.201700489.

BibTeX

@article{osaki2017vitro,
  title     = {{In Vitro Microfluidic Models for Neurodegenerative Disorders}},
  author    = {Osaki, Tatsuya and Shin, Yoojin and Sivathanu, Vivek and Campisi, Marco and Kamm, Roger Dale},
  journal   = {Advanced Healthcare Materials},
  year      = {2017},
  volume    = {7},
  number    = {2},
  pages     = {1700489},
  doi       = {10.1002/adhm.201700489},
  url       = {https://doi.org/10.1002/adhm.201700489}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
201899
20191414
20202323
20211414
20222424
20232727
20242929
20251616
202699

Its field-weighted citation impact is 0.99: it has been cited 0.99 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research

  • organ-on-a-chip
  • neurodegenerative diseases
  • Alzheimer's disease
  • Parkinson's disease
  • amyotrophic lateral sclerosis
  • chemical gradients
  • mechanical microenvironment
  • drug discovery

Work with this paper

Most-cited papers in Engineering

All highly cited Engineering papers

Questions about this paper

How do I cite this paper in APA style?

Osaki, T., Shin, Y., Sivathanu, V., Campisi, M., & Kamm, R. D. (2017). In Vitro Microfluidic Models for Neurodegenerative Disorders. Advanced Healthcare Materials, 7(2), 1700489. https://doi.org/10.1002/adhm.201700489

How many times has this paper been cited?

166 times, according to OpenAlex on 27 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at PORTO@Iris: sign in and open the PDF from this page.

Who wrote this paper?

Tatsuya Osaki, Yoojin Shin, Vivek Sivathanu, Marco Campisi, Roger Dale Kamm.

What is the DOI of this paper?

10.1002/adhm.201700489, permanently at https://doi.org/10.1002/adhm.201700489. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 27 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.