Conference paper · 2003

Improvements to amorphous silicon radiation detectors by doping profile changes

John S. Drewery, G. Cho, Wan‐Shick Hong, K.K. Lee, S.N. Kaplan, Ali Mireshghi, V. Perez-Mendez, Jinhui Tao, D. Wildermuth

IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 70, 76–78 · Published 2 January 2003 · DOI 10.1109/nssmic.1992.301151

View at the publisherCite this paper

In brief

“Improvements to amorphous silicon radiation detectors by doping profile changes” is a 2003 conference paper by John S. Drewery and 8 co-authors, published in IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC). OpenAlex counts 0 citations as of 16 November 2026. The publisher's version is not open access, and OpenAlex records no free legal copy.

Citations
0
References
5
Authors
9

Abstract

Application of thick ( approximately 50 mu m) amorphous Si p-i-n diodes as direct radiation detectors for minimum ionizing particles is hampered by the need to apply large bias voltages in order fully to deplete the detecting intrinsic layer, which typically contains 5-10*10/sup 14/ ionizable dangling bonds per cm/sup 3/. A voltage of about 1… Read the full abstract at the publisher.

Excerpt. This paper is not open access.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Drewery, J. S., Cho, G., Hong, W., Lee, K., Kaplan, S., Mireshghi, A., Perez-Mendez, V., Tao, J., & Wildermuth, D. (2003). Improvements to amorphous silicon radiation detectors by doping profile changes. IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 70, 76–78. https://doi.org/10.1109/nssmic.1992.301151

MLA 9

Drewery, John S., et al. “Improvements to amorphous silicon radiation detectors by doping profile changes.” IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), vol. 70, 2003, pp. 76–78. https://doi.org/10.1109/nssmic.1992.301151.

Chicago

Drewery, John S., G. Cho, Wan‐Shick Hong, K.K. Lee, S.N. Kaplan, Ali Mireshghi, V. Perez-Mendez, Jinhui Tao, and D. Wildermuth. 2003. “Improvements to amorphous silicon radiation detectors by doping profile changes.” IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) 70: 76–78. https://doi.org/10.1109/nssmic.1992.301151.

Harvard

Drewery, J. S. et al. (2003) ‘Improvements to amorphous silicon radiation detectors by doping profile changes’, IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 70, pp. 76–78. doi:10.1109/nssmic.1992.301151.

IEEE

J. S. Drewery et al., “Improvements to amorphous silicon radiation detectors by doping profile changes,” IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), vol. 70, pp. 76–78, 2003, doi: 10.1109/nssmic.1992.301151.

BibTeX

@inproceedings{drewery2003improvements,
  title     = {{Improvements to amorphous silicon radiation detectors by doping profile changes}},
  author    = {Drewery, John S. and Cho, G. and Hong, Wan‐Shick and Lee, K.K. and Kaplan, S.N. and Mireshghi, Ali and Perez-Mendez, V. and Tao, Jinhui and Wildermuth, D.},
  booktitle = {IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)},
  year      = {2003},
  volume    = {70},
  pages     = {76--78},
  doi       = {10.1109/nssmic.1992.301151},
  url       = {https://doi.org/10.1109/nssmic.1992.301151}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Particle Detector Development and Performance

  • amorphous silicon
  • radiation detectors
  • PIN diodes
  • dopant distribution
  • intrinsic layer
  • depletion voltage
  • dangling bonds
  • leakage current

Work with this paper

Most-cited papers in Physics and Astronomy

All highly cited Physics and Astronomy papers

Questions about this paper

How do I cite this paper in APA style?

Drewery, J. S., Cho, G., Hong, W., Lee, K., Kaplan, S., Mireshghi, A., Perez-Mendez, V., Tao, J., & Wildermuth, D. (2003). Improvements to amorphous silicon radiation detectors by doping profile changes. IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 70, 76–78. https://doi.org/10.1109/nssmic.1992.301151

How many times has this paper been cited?

0 times, according to OpenAlex on 16 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

OpenAlex records no free legal copy. Check your library's access, the authors' pages or a repository, or ask the corresponding author for a copy.

Who wrote this paper?

John S. Drewery, G. Cho, Wan‐Shick Hong, K.K. Lee, S.N. Kaplan, Ali Mireshghi, V. Perez-Mendez, Jinhui Tao, D. Wildermuth.

What is the DOI of this paper?

10.1109/nssmic.1992.301151. The permanent link is https://doi.org/10.1109/nssmic.1992.301151.

Bibliographic data from OpenAlex (CC0), last checked 16 November 2026. ResearchGuru does not host this paper; the links go to the publisher or the repository that does.