Journal article · 2010 · Open access
Identifying Actives from HTS Data Sets: Practical Approaches for the Selection of an Appropriate HTS Data-Processing Method and Quality Control Review
SLAS DISCOVERY, 16(1), 1–14 · Published 16 December 2010 · DOI 10.1177/1087057110389039
In brief
“Identifying Actives from HTS Data Sets: Practical Approaches for the Selection of an Appropriate HTS Data-Processing Method and Quality Control Review” is a 2010 journal article by Tong Ying Shun and 3 co-authors, published in SLAS DISCOVERY. OpenAlex counts 93 citations as of 23 November 2026. It is open access under a CC BY-NC-ND licence: the full text is free to read at SLAS DISCOVERY.
- Citations
- 93
- Most cited in
- 2025 (14)
- Field-weighted impact
- 2.66
- References
- 27
- Authors
- 4
Abstract
High-throughput screening (HTS) has achieved a dominant role in drug discovery over the past 2 decades. The goal of HTS is to identify active compounds (hits) by screening large numbers of diverse chemical compounds against selected targets and/or cellular phenotypes. The HTS process consists of multiple automated steps involving compound handling, liquid transfers, and assay signal capture, all of which unavoidably contribute to systematic variation in the screening data. The challenge is to distinguish biologically active compounds from assay variability. Traditional plate controls-based and non-controls-based statistical methods have been widely used for HTS data processing and active identification by both the pharmaceutical industry and academic sectors. More recently, improved robust statistical methods have been introduced, reducing the impact of systematic row/column effects in HTS data. To apply such robust methods effectively and properly, we need to understand their necessity and functionality. Data from 6 HTS case histories are presented to illustrate that robust statistical methods may sometimes be misleading and can result in more, rather than less, false positives or false negatives. In practice, no single method is the best hit detection method for every HTS data set. However, to aid the selection of the most appropriate HTS data-processing and active identification methods, the authors developed a 3-step statistical decision methodology. Step 1 is to determine the most appropriate HTS data-processing method and establish criteria for quality control review and active identification from 3-day assay signal window and DMSO validation tests. Step 2 is to perform a multilevel statistical and graphical review of the screening data to exclude data that fall outside the quality control criteria. Step 3 is to apply the established active criterion to the quality-assured data to identify the active compounds.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Shun, T. Y., Lazo, J. S., Sharlow, E. R., & Johnston, P. A. (2010). Identifying Actives from HTS Data Sets: Practical Approaches for the Selection of an Appropriate HTS Data-Processing Method and Quality Control Review. SLAS DISCOVERY, 16(1), 1–14. https://doi.org/10.1177/1087057110389039
MLA 9
Shun, Tong Ying, et al. “Identifying Actives from HTS Data Sets: Practical Approaches for the Selection of an Appropriate HTS Data-Processing Method and Quality Control Review.” SLAS DISCOVERY, vol. 16, no. 1, 2010, pp. 1–14. https://doi.org/10.1177/1087057110389039.
Chicago
Shun, Tong Ying, John Stephen Lazo, Elizabeth R. Sharlow, and Paul A. Johnston. 2010. “Identifying Actives from HTS Data Sets: Practical Approaches for the Selection of an Appropriate HTS Data-Processing Method and Quality Control Review.” SLAS DISCOVERY 16 (1): 1–14. https://doi.org/10.1177/1087057110389039.
Harvard
Shun, T. Y. et al. (2010) ‘Identifying Actives from HTS Data Sets: Practical Approaches for the Selection of an Appropriate HTS Data-Processing Method and Quality Control Review’, SLAS DISCOVERY, 16(1), pp. 1–14. doi:10.1177/1087057110389039.
IEEE
T. Y. Shun, J. S. Lazo, E. R. Sharlow, and P. A. Johnston, “Identifying Actives from HTS Data Sets: Practical Approaches for the Selection of an Appropriate HTS Data-Processing Method and Quality Control Review,” SLAS DISCOVERY, vol. 16, no. 1, pp. 1–14, 2010, doi: 10.1177/1087057110389039.
BibTeX
@article{shun2010identifying,
title = {{Identifying Actives from HTS Data Sets: Practical Approaches for the Selection of an Appropriate HTS Data-Processing Method and Quality Control Review}},
author = {Shun, Tong Ying and Lazo, John Stephen and Sharlow, Elizabeth R. and Johnston, Paul A.},
journal = {SLAS DISCOVERY},
year = {2010},
volume = {16},
number = {1},
pages = {1--14},
doi = {10.1177/1087057110389039},
url = {https://doi.org/10.1177/1087057110389039}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Citations by year
| Year | Citations | Share of the best year |
|---|---|---|
| 2017 | 1 | |
| 2018 | 3 | |
| 2019 | 3 | |
| 2020 | 2 | |
| 2021 | 6 | |
| 2022 | 1 | |
| 2023 | 10 | |
| 2024 | 5 | |
| 2025 | 14 | |
| 2026 | 4 |
Its field-weighted citation impact is 2.66: it has been cited 2.66 times as often as the average work of the same field, type and year (1.00 is the world average).
Topic and keywords
Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Drug Discovery › Computational Drug Discovery Methods
- high-throughput screening
- hit identification
- robust statistical methods
- false positives
- false-negative results
- assay variability
Work with this paper
Most-cited papers in Pharmacology, Toxicology and Pharmaceutics
- AutoDock Vina: Improving the speed and accuracy of docking with a new scoring function, efficient optimization, and multithreadingOleg Trott, Arthur J. Olson · Journal of Computational Chemistry · 2009 · 39,860 citations
- AutoDock4 and AutoDockTools4: Automated docking with selective receptor flexibilityGarrett M. Morris, Ruth Huey, William Lindstrom and 4 more · Journal of Computational Chemistry · 2009 · 26,508 citations
- Development and testing of a general amber force fieldJunmei Wang, Romain M. Wolf, James W. Caldwell and 2 more · Journal of Computational Chemistry · 2004 · 20,080 citations
- Experimental and computational approaches to estimate solubility and permeability in drug discovery and development settings 1PII of original article: S0169-409X(96)00423-1. The article was originally published in Advanced Drug Delivery Reviews 23 (1997) 3–25. 1Christopher A. Lipinski, Franco Lombardo, Beryl W. Dominy and 1 more · Advanced Drug Delivery Reviews · 2001 · 19,638 citations
- SwissADME: a free web tool to evaluate pharmacokinetics, drug-likeness and medicinal chemistry friendliness of small moleculesAntoine Daina, Olivier Alain Michielin, Vincent Zoete · Scientific Reports · 2017 · 19,557 citations
All highly cited Pharmacology, Toxicology and Pharmaceutics papers
Questions about this paper
How do I cite this paper in APA style?
Shun, T. Y., Lazo, J. S., Sharlow, E. R., & Johnston, P. A. (2010). Identifying Actives from HTS Data Sets: Practical Approaches for the Selection of an Appropriate HTS Data-Processing Method and Quality Control Review. SLAS DISCOVERY, 16(1), 1–14. https://doi.org/10.1177/1087057110389039
How many times has this paper been cited?
93 times, according to OpenAlex on 23 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at SLAS DISCOVERY: sign in and open the full text from this page.
Who wrote this paper?
Tong Ying Shun, John Stephen Lazo, Elizabeth R. Sharlow, Paul A. Johnston.
What is the DOI of this paper?
10.1177/1087057110389039, permanently at https://doi.org/10.1177/1087057110389039. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 23 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.