Conference paper · 2023 · Open access

Hydrogel-actuated Soft Sucker with Mucus Secretion

Tianqi Yue, A. Keller, Daniel Gosden, Hermes Gadêlha, Jonathan Michael Rossiter

IEEE International Conference on Soft Robotics (RoboSoft), 1–6 · Published 3 April 2023 · DOI 10.1109/robosoft55895.2023.10122110

Open full textView at the publisherCite this paper

In brief

“Hydrogel-actuated Soft Sucker with Mucus Secretion” is a 2023 conference paper by Tianqi Yue and 4 co-authors, published in IEEE International Conference on Soft Robotics (RoboSoft). OpenAlex counts 0 citations as of 22 November 2026. It is open access: the full text is free to read at Bristol Research (University of Bristol).

Citations
0
References
16
Authors
5

Abstract

Suction is a nature-inspired adhesion strategy which has been successfully applied in industry for decades. Their high adhesive force and energy efficiency make suckers light weight and low cost. However, the requirement for compact grippers conflicts with the bulky and heavy vacuum pumps used in existing suckers. This work proposes a novel hydrogel-actuated soft sucker inspired by the octopus sucker to realise compact, compliant and adaptive suction which needs no external vacuum supply. The sucker is actuated through volume change within a double-network, thermo-sensitive hydrogel. When the hydrogel is heated, its molecular structure collapses, generating a suction force and simultaneously secreting water around the sucker rim to strengthen the suction. When the hy-drogel is cooled, it reabsorbs water, recovering its initial shape and eliminating the suction force. On a dry on-land surface, the proposed sucker is capable of adhering to rough surfaces by utilizing water secretion, similar to the mucus secretion of octopus suckers. Underwater, the sucker further exhibits reversible attachment and detachment capability. Simulation results and experimental results demonstrate the practicality of this suction strategy. By applying a current of 0.3 A to generate joule heat, pressure differentials of -4.54 kPa and -4.02 kPa with respect to atmospheric pressure can be generated underwater and on land, respectively. We believe this hydrogel-actuated soft sucker is a significant new technology for next-generation safe, compliant and compact robotic suckers.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Yue, T., Keller, A., Gosden, D., Gadêlha, H., & Rossiter, J. M. (2023). Hydrogel-actuated Soft Sucker with Mucus Secretion. IEEE International Conference on Soft Robotics (RoboSoft), 1–6. https://doi.org/10.1109/robosoft55895.2023.10122110

MLA 9

Yue, Tianqi, et al. “Hydrogel-actuated Soft Sucker with Mucus Secretion.” IEEE International Conference on Soft Robotics (RoboSoft), 2023, pp. 1–6. https://doi.org/10.1109/robosoft55895.2023.10122110.

Chicago

Yue, Tianqi, A. Keller, Daniel Gosden, Hermes Gadêlha, and Jonathan Michael Rossiter. 2023. “Hydrogel-actuated Soft Sucker with Mucus Secretion.” IEEE International Conference on Soft Robotics (RoboSoft): 1–6. https://doi.org/10.1109/robosoft55895.2023.10122110.

Harvard

Yue, T. et al. (2023) ‘Hydrogel-actuated Soft Sucker with Mucus Secretion’, IEEE International Conference on Soft Robotics (RoboSoft), pp. 1–6. doi:10.1109/robosoft55895.2023.10122110.

IEEE

T. Yue, A. Keller, D. Gosden, H. Gadêlha, and J. M. Rossiter, “Hydrogel-actuated Soft Sucker with Mucus Secretion,” IEEE International Conference on Soft Robotics (RoboSoft), pp. 1–6, 2023, doi: 10.1109/robosoft55895.2023.10122110.

BibTeX

@inproceedings{yue2023hydrogel,
  title     = {{Hydrogel-actuated Soft Sucker with Mucus Secretion}},
  author    = {Yue, Tianqi and Keller, A. and Gosden, Daniel and Gadêlha, Hermes and Rossiter, Jonathan Michael},
  booktitle = {IEEE International Conference on Soft Robotics (RoboSoft)},
  year      = {2023},
  pages     = {1--6},
  doi       = {10.1109/robosoft55895.2023.10122110},
  url       = {https://doi.org/10.1109/robosoft55895.2023.10122110}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications

  • hydrogel actuation
  • octopus suckers
  • mucus secretion
  • double-network hydrogel
  • thermosensitive hydrogel
  • Joule heating
  • wet adhesion
  • rough surface adhesion

Work with this paper

Most-cited papers in Engineering

All highly cited Engineering papers

Questions about this paper

How do I cite this paper in APA style?

Yue, T., Keller, A., Gosden, D., Gadêlha, H., & Rossiter, J. M. (2023). Hydrogel-actuated Soft Sucker with Mucus Secretion. IEEE International Conference on Soft Robotics (RoboSoft), 1–6. https://doi.org/10.1109/robosoft55895.2023.10122110

How many times has this paper been cited?

0 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Bristol Research (University of Bristol): sign in and open the full text from this page.

Who wrote this paper?

Tianqi Yue, A. Keller, Daniel Gosden, Hermes Gadêlha, Jonathan Michael Rossiter.

What is the DOI of this paper?

10.1109/robosoft55895.2023.10122110, permanently at https://doi.org/10.1109/robosoft55895.2023.10122110. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.