Journal article · 2006 · Open access
Highly sensitive determination of lanthanides by capillary electrophoresis with direct visible detection after precapillary complexation with aromatic polyaminocarboxylate and additionally applying dynamic ternary complexation with nitrilotriacetic acid
Electrophoresis, 27(15), 3093–3100 · Published 28 June 2006 · DOI 10.1002/elps.200500828
In brief
“Highly sensitive determination of lanthanides by capillary electrophoresis with direct visible detection after precapillary complexation with aromatic polyaminocarboxylate and additionally applying dynamic ternary complexation with nitrilotriacetic acid” is a 2006 journal article by Shingo Saito and 2 co-authors, published in Electrophoresis. OpenAlex counts 16 citations as of 20 November 2026. It is open access: the full text is free to read at Institutional Repositories DataBase (IRDB).
- Citations
- 16
- Most cited in
- 2016 (3)
- Field-weighted impact
- 0.59
- References
- 54
- Authors
- 3
Abstract
A newly synthesized aromatic polyaminocarboxylate (NBD-ABEDTA, H(4)L) was applied to precapillary derivatizing capillary electrophoresis as a chelating reagent for lanthanide ions (Ln(3+)). The Ln-L complexes provide both kinetic stability on dissociation due to their methyl-EDTA coordinating structure, and high light absorptivity (epsilon(max) = 2.4 x 10(4) cm(-1) mol(-1) dm(3)) in the visible region at 469 nm thanks to their nitrobenzofurazan moiety. A ligand was employed for capillary zone electrophoresis based on a unique concept: both precapillary and dynamic on-capillary complexation were carried out on one center-metal ion to achieve high resolution. As a ternary complex-formation agent, iminodiacetate (IDA), bound to the mother complex (Ln-L), was added to the carrier buffer solution. The carrier buffer solution of 9.5 mmol.dm(-3) (pH 9.45) borate and 33.5 mmol.dm(-3) IDA, drastically improved the resolution among Ln(3+) ions. Each of the Ln complexes was effectively separated, except for Pr-Sm. Furthermore, the absence of L from the carrier solution, which stabilizes the baseline fluctuation, provided low LOD (typically 4.2 x 10(-7) mol.dm(-3)). This strongly suggests that Ln-L complexes are kinetically stable even with a large excess of IDA. Quite unexpectedly, the order of migration differs from that of the atomic number, inverting at Nd. This is due to the effect of the cavity size of the residual coordination sites on the ternary complexation and the electronic density of Ln(3+).
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Saito, S., Danzaka, N., & Hoshi, S. (2006). Highly sensitive determination of lanthanides by capillary electrophoresis with direct visible detection after precapillary complexation with aromatic polyaminocarboxylate and additionally applying dynamic ternary complexation with nitrilotriacetic acid. Electrophoresis, 27(15), 3093–3100. https://doi.org/10.1002/elps.200500828
MLA 9
Saito, Shingo, et al. “Highly sensitive determination of lanthanides by capillary electrophoresis with direct visible detection after precapillary complexation with aromatic polyaminocarboxylate and additionally applying dynamic ternary complexation with nitrilotriacetic acid.” Electrophoresis, vol. 27, no. 15, 2006, pp. 3093–3100. https://doi.org/10.1002/elps.200500828.
Chicago
Saito, Shingo, Naoki Danzaka, and Suwaru Hoshi. 2006. “Highly sensitive determination of lanthanides by capillary electrophoresis with direct visible detection after precapillary complexation with aromatic polyaminocarboxylate and additionally applying dynamic ternary complexation with nitrilotriacetic acid.” Electrophoresis 27 (15): 3093–3100. https://doi.org/10.1002/elps.200500828.
Harvard
Saito, S., Danzaka, N. and Hoshi, S. (2006) ‘Highly sensitive determination of lanthanides by capillary electrophoresis with direct visible detection after precapillary complexation with aromatic polyaminocarboxylate and additionally applying dynamic ternary complexation with nitrilotriacetic acid’, Electrophoresis, 27(15), pp. 3093–3100. doi:10.1002/elps.200500828.
IEEE
S. Saito, N. Danzaka, and S. Hoshi, “Highly sensitive determination of lanthanides by capillary electrophoresis with direct visible detection after precapillary complexation with aromatic polyaminocarboxylate and additionally applying dynamic ternary complexation with nitrilotriacetic acid,” Electrophoresis, vol. 27, no. 15, pp. 3093–3100, 2006, doi: 10.1002/elps.200500828.
BibTeX
@article{saito2006highly,
title = {{Highly sensitive determination of lanthanides by capillary electrophoresis with direct visible detection after precapillary complexation with aromatic polyaminocarboxylate and additionally applying dynamic ternary complexation with nitrilotriacetic acid}},
author = {Saito, Shingo and Danzaka, Naoki and Hoshi, Suwaru},
journal = {Electrophoresis},
year = {2006},
volume = {27},
number = {15},
pages = {3093--3100},
doi = {10.1002/elps.200500828},
url = {https://doi.org/10.1002/elps.200500828}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Citations by year
| Year | Citations | Share of the best year |
|---|---|---|
| 2012 | 1 | |
| 2014 | 1 | |
| 2016 | 3 | |
| 2017 | 1 | |
| 2018 | 1 | |
| 2021 | 1 | |
| 2023 | 1 | |
| 2024 | 1 |
Its field-weighted citation impact is 0.59: it has been cited 0.59 times as often as the average work of the same field, type and year (1.00 is the world average).
Topic and keywords
Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- lanthanide determination
- capillary electrophoresis
- nitrilotriacetic acid
- iminodiacetate
- chelating agents
- visible detection
Work with this paper
Most-cited papers in Engineering
- A Closed‐form Equation for Predicting the Hydraulic Conductivity of Unsaturated SoilsMartinus Th. van Genuchten · Soil Science Society of America Journal · 1980 · 28,197 citations
- An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experimentsW. C. Oliver, George M. Pharr · Journal of materials research/Pratt's guide to venture capital sources · 1992 · 27,379 citations
- Digital communicationsOwen Bishop · Routledge eBooks · 2007 · 24,890 citations
- The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysisNorden Eh Huang, Zhengwei Shen, Steven R. Long and 6 more · Proceedings of the Royal Society A Mathematical Physical and Engineering Sciences · 1998 · 24,008 citations
- Numerical Heat Transfer and Fluid FlowSuhas V. Patankar · CRC Press eBooks · 2018 · 23,491 citations
Questions about this paper
How do I cite this paper in APA style?
Saito, S., Danzaka, N., & Hoshi, S. (2006). Highly sensitive determination of lanthanides by capillary electrophoresis with direct visible detection after precapillary complexation with aromatic polyaminocarboxylate and additionally applying dynamic ternary complexation with nitrilotriacetic acid. Electrophoresis, 27(15), 3093–3100. https://doi.org/10.1002/elps.200500828
How many times has this paper been cited?
16 times, according to OpenAlex on 20 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at Institutional Repositories DataBase (IRDB): sign in and open the full text from this page.
Who wrote this paper?
Shingo Saito, Naoki Danzaka, Suwaru Hoshi.
What is the DOI of this paper?
10.1002/elps.200500828, permanently at https://doi.org/10.1002/elps.200500828. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 20 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.