Dissertation · 2011 · Open access
High-resolution electron tomography on beam-sensitive carbon materials
OPen Access Repositorium der Universität Ulm (OPARU) (Ulm University) · Published 1 January 2011 · DOI 10.18725/oparu-1928
In brief
“High-resolution electron tomography on beam-sensitive carbon materials” is a 2011 dissertation by Jens Leschner, published in OPen Access Repositorium der Universität Ulm (OPARU) (Ulm University). OpenAlex counts 1 citations as of 16 November 2026. It is open access: the full text is free to read at Universität Ulm, Kommunikations- und Informationszentrum (kiz).
- Citations
- 1
- Most cited in
- 2012 (1)
- Authors
- 1
Abstract
In this work a protocol for bright-field electron tomography in the transmission electron microscope (TEM) is developed. This protocol provides high resolution in 3D better than 1nm. It enables to study materials prone to radiolysis effects such as carbon materials. For the latter an aberration corrected TEM operated at a low acceleration voltage of 80kV is necessary to reduce the knock-on related beam damage. This protocol is exemplified on commercially available Vulcan XC-72 carbon soot particles which serve as a support for catalytically active nanoparticles (here platinum). This approach enables to visualize and quantify the internal three-dimensional graphitic nanostructure with ~0.35nm graphitic interplanar distance by layer distance, fringe length and tortuosity providing statistical measures for the 3D carbon volume. The protocol ensures that the sample withstands the entire tilt series acquisition by a minimum dose protocol. The appropriate imaging conditions are specified and experimentally preserved by an automatic focus and stigmation (AFS) module correcting focus and astigmatism intermittently at each tilt angle with a high accuracy required for aberration corrected high-resolution TEM. A new iterative self-consistent alignment strategy ensures high resolution in the three-dimensional reconstruction. The quantification of the entire three-dimensional carbon volume is shown to be superior to a two-dimensional projection analysis and making calibrations with x-ray data redundant.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Leschner, J. (2011). High-resolution electron tomography on beam-sensitive carbon materials. OPen Access Repositorium der Universität Ulm (OPARU) (Ulm University). https://doi.org/10.18725/oparu-1928
MLA 9
Leschner, Jens. “High-resolution electron tomography on beam-sensitive carbon materials.” OPen Access Repositorium der Universität Ulm (OPARU) (Ulm University), 2011. https://doi.org/10.18725/oparu-1928.
Chicago
Leschner, Jens. 2011. “High-resolution electron tomography on beam-sensitive carbon materials.” OPen Access Repositorium der Universität Ulm (OPARU) (Ulm University). https://doi.org/10.18725/oparu-1928.
Harvard
Leschner, J. (2011) ‘High-resolution electron tomography on beam-sensitive carbon materials’, OPen Access Repositorium der Universität Ulm (OPARU) (Ulm University). doi:10.18725/oparu-1928.
IEEE
J. Leschner, “High-resolution electron tomography on beam-sensitive carbon materials,” OPen Access Repositorium der Universität Ulm (OPARU) (Ulm University), 2011, doi: 10.18725/oparu-1928.
BibTeX
@phdthesis{leschner2011high,
title = {{High-resolution electron tomography on beam-sensitive carbon materials}},
author = {Leschner, Jens},
year = {2011},
doi = {10.18725/oparu-1928},
url = {https://doi.org/10.18725/oparu-1928}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Topic and keywords
Life Sciences › Biochemistry, Genetics and Molecular Biology › Structural Biology › Advanced Electron Microscopy Techniques and Applications
- electron tomography
- beam-sensitive materials
- carbon materials
- radiolysis
- beam damage
- knock-on damage
- low acceleration voltage
- aberration-corrected TEM
Work with this paper
Most-cited papers in Biochemistry, Genetics and Molecular Biology
- PROTEIN MEASUREMENT WITH THE FOLIN PHENOL REAGENTOliver H. Lowry, NiraJ. Rosebrough, A. Lewis Farr and 1 more · Journal of Biological Chemistry · 1951 · 316,470 citations
- A Rapid and Sensitive Method for the Quantitation of Microgram Quantities of Protein Utilizing the Principle of Protein-Dye BindingM Bradford · Analytical Biochemistry · 1976 · 256,780 citations
- Analysis of Relative Gene Expression Data Using Real-Time Quantitative PCR and the 2−ΔΔCT MethodKenneth J. Livak, Thomas D. Schmittgen · Methods · 2001 · 184,418 citations
- Molecular Cloning: A Laboratory ManualJoseph Sambrook, Elisabeth Fritsch, Tom Maniatis · UCLA - Biblioteca de Ciencias de la Salud · 1989 · 133,493 citations
- Basic Local Alignment Search ToolStephen F. Altschul, Warren R. Gish, Webb Miller and 2 more · Journal of Molecular Biology · 1990 · 100,529 citations
All highly cited Biochemistry, Genetics and Molecular Biology papers
Questions about this paper
How do I cite this paper in APA style?
Leschner, J. (2011). High-resolution electron tomography on beam-sensitive carbon materials. OPen Access Repositorium der Universität Ulm (OPARU) (Ulm University). https://doi.org/10.18725/oparu-1928
How many times has this paper been cited?
1 times, according to OpenAlex on 16 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access: read the free full text at Universität Ulm, Kommunikations- und Informationszentrum (kiz).
Who wrote this paper?
Jens Leschner.
What is the DOI of this paper?
10.18725/oparu-1928. The permanent link is https://doi.org/10.18725/oparu-1928.
Bibliographic data from OpenAlex (CC0), last checked 16 November 2026. ResearchGuru does not host this paper; the links go to the publisher or the repository that does.