Journal article · 2021 · Open access
Haptic User Interface of a Cable-Driven Input Device to Control the End Effector of a Surgical Telemanipulation System
Current Directions in Biomedical Engineering, 7(2), 211–214 · Published 1 October 2021 · DOI 10.1515/cdbme-2021-2054
In brief
“Haptic User Interface of a Cable-Driven Input Device to Control the End Effector of a Surgical Telemanipulation System” is a 2021 journal article by Max B. Schäfer and 2 co-authors, published in Current Directions in Biomedical Engineering. OpenAlex counts 1 citations as of 22 November 2026. It is open access under a CC BY licence: the full text is free to read at Current Directions in Biomedical Engineering.
- Citations
- 1
- Most cited in
- 2024 (1)
- Field-weighted impact
- 0.10
- References
- 12
- Authors
- 3
Abstract
In robotic telemanipulation for minimally-invasive surgery, lack of haptic sensation and non-congruent movement of input device and manipulator are major drawbacks. Input devices based on cable-driven parallel mechanisms have the potential to be a stiff alternative to input devices based on rigid parallel or serial kinematics by offering low inertia and a scalable workspace. In this paper, the haptic user interface of a cable-driven input device and its technical specifications are presented and assessed. The haptic user interface allows to intuitively control the gripping movement of the manipulator’s end effector by providing a two-finger precision grasp. By design, the interface allows to command input angles between 0° and 45°. Furthermore, interaction forces from the manipulator’s end effector can be displayed to the user’s twofinger grasp in a range from 0 N to 6 N with a frequency bandwidth of 17 Hz.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Schäfer, M. B., Al-Abboodi, B. A., & Pott, P. P. (2021). Haptic User Interface of a Cable-Driven Input Device to Control the End Effector of a Surgical Telemanipulation System. Current Directions in Biomedical Engineering, 7(2), 211–214. https://doi.org/10.1515/cdbme-2021-2054
MLA 9
Schäfer, Max B., et al. “Haptic User Interface of a Cable-Driven Input Device to Control the End Effector of a Surgical Telemanipulation System.” Current Directions in Biomedical Engineering, vol. 7, no. 2, 2021, pp. 211–214. https://doi.org/10.1515/cdbme-2021-2054.
Chicago
Schäfer, Max B., Bha A. Al-Abboodi, and Peter Paul Pott. 2021. “Haptic User Interface of a Cable-Driven Input Device to Control the End Effector of a Surgical Telemanipulation System.” Current Directions in Biomedical Engineering 7 (2): 211–214. https://doi.org/10.1515/cdbme-2021-2054.
Harvard
Schäfer, M. B., Al-Abboodi, B. A. and Pott, P. P. (2021) ‘Haptic User Interface of a Cable-Driven Input Device to Control the End Effector of a Surgical Telemanipulation System’, Current Directions in Biomedical Engineering, 7(2), pp. 211–214. doi:10.1515/cdbme-2021-2054.
IEEE
M. B. Schäfer, B. A. Al-Abboodi, and P. P. Pott, “Haptic User Interface of a Cable-Driven Input Device to Control the End Effector of a Surgical Telemanipulation System,” Current Directions in Biomedical Engineering, vol. 7, no. 2, pp. 211–214, 2021, doi: 10.1515/cdbme-2021-2054.
BibTeX
@article{schafer2021haptic,
title = {{Haptic User Interface of a Cable-Driven Input Device to Control the End Effector of a Surgical Telemanipulation System}},
author = {Schäfer, Max B. and Al-Abboodi, Bha A. and Pott, Peter Paul},
journal = {Current Directions in Biomedical Engineering},
year = {2021},
volume = {7},
number = {2},
pages = {211--214},
doi = {10.1515/cdbme-2021-2054},
url = {https://doi.org/10.1515/cdbme-2021-2054}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Topic and keywords
Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
- haptic interface
- cable-driven parallel mechanism
- minimally invasive surgery
- end-effector control
- force feedback
- teleoperation
Work with this paper
Most-cited papers in Engineering
- A Closed‐form Equation for Predicting the Hydraulic Conductivity of Unsaturated SoilsMartinus Th. van Genuchten · Soil Science Society of America Journal · 1980 · 28,197 citations
- An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experimentsW. C. Oliver, George M. Pharr · Journal of materials research/Pratt's guide to venture capital sources · 1992 · 27,379 citations
- Digital communicationsOwen Bishop · Routledge eBooks · 2007 · 24,890 citations
- The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysisNorden Eh Huang, Zhengwei Shen, Steven R. Long and 6 more · Proceedings of the Royal Society A Mathematical Physical and Engineering Sciences · 1998 · 24,008 citations
- Numerical Heat Transfer and Fluid FlowSuhas V. Patankar · CRC Press eBooks · 2018 · 23,491 citations
Questions about this paper
How do I cite this paper in APA style?
Schäfer, M. B., Al-Abboodi, B. A., & Pott, P. P. (2021). Haptic User Interface of a Cable-Driven Input Device to Control the End Effector of a Surgical Telemanipulation System. Current Directions in Biomedical Engineering, 7(2), 211–214. https://doi.org/10.1515/cdbme-2021-2054
How many times has this paper been cited?
1 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at Current Directions in Biomedical Engineering: sign in and open the PDF from this page.
Who wrote this paper?
Max B. Schäfer, Bha A. Al-Abboodi, Peter Paul Pott.
What is the DOI of this paper?
10.1515/cdbme-2021-2054, permanently at https://doi.org/10.1515/cdbme-2021-2054. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.