Journal article · 2023
GelStereo BioTip: Self-Calibrating Bionic Fingertip Visuotactile Sensor for Robotic Manipulation
IEEE/ASME Transactions on Mechatronics, 29(4), 2451–2462 · Published 13 December 2023 · DOI 10.1109/tmech.2023.3336335
In brief
“GelStereo BioTip: Self-Calibrating Bionic Fingertip Visuotactile Sensor for Robotic Manipulation” is a 2023 journal article by Shaowei Cui and 6 co-authors, published in IEEE/ASME Transactions on Mechatronics. OpenAlex counts 16 citations as of 22 November 2026. The publisher's version is not open access, and OpenAlex records no free legal copy.
- Citations
- 16
- Most cited in
- 2025 (8)
- Field-weighted impact
- 1.26
- References
- 35
- Authors
- 7
Abstract
High-resolution visuotactile sensors are often bulky and have flat contact shapes, making it difficult to integrate into dexterous multifinger fingertips and perform manipulation tasks smoothly. In this article, we present a soft, low-cost, biomimetic fingertip-sized visuotactile sensor, which can perceive high-precision 3-D surface deformation. This novel sensor, named GelStereo BioTip, adopts stereo vision system to… Read the full abstract at the publisher.
Excerpt. This paper is not open access.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Cui, S., Wang, S., Zhang, C., Wang, R., Zhang, B., Zhang, S., & Wang, Y. (2023). GelStereo BioTip: Self-Calibrating Bionic Fingertip Visuotactile Sensor for Robotic Manipulation. IEEE/ASME Transactions on Mechatronics, 29(4), 2451–2462. https://doi.org/10.1109/tmech.2023.3336335
MLA 9
Cui, Shaowei, et al. “GelStereo BioTip: Self-Calibrating Bionic Fingertip Visuotactile Sensor for Robotic Manipulation.” IEEE/ASME Transactions on Mechatronics, vol. 29, no. 4, 2023, pp. 2451–2462. https://doi.org/10.1109/tmech.2023.3336335.
Chicago
Cui, Shaowei, Shuo Wang, Chaofan Zhang, Rui Wang, Boyue Zhang, Shaolin Zhang, and Yu Wang. 2023. “GelStereo BioTip: Self-Calibrating Bionic Fingertip Visuotactile Sensor for Robotic Manipulation.” IEEE/ASME Transactions on Mechatronics 29 (4): 2451–2462. https://doi.org/10.1109/tmech.2023.3336335.
Harvard
Cui, S. et al. (2023) ‘GelStereo BioTip: Self-Calibrating Bionic Fingertip Visuotactile Sensor for Robotic Manipulation’, IEEE/ASME Transactions on Mechatronics, 29(4), pp. 2451–2462. doi:10.1109/tmech.2023.3336335.
IEEE
S. Cui et al., “GelStereo BioTip: Self-Calibrating Bionic Fingertip Visuotactile Sensor for Robotic Manipulation,” IEEE/ASME Transactions on Mechatronics, vol. 29, no. 4, pp. 2451–2462, 2023, doi: 10.1109/tmech.2023.3336335.
BibTeX
@article{cui2023gelstereo,
title = {{GelStereo BioTip: Self-Calibrating Bionic Fingertip Visuotactile Sensor for Robotic Manipulation}},
author = {Cui, Shaowei and Wang, Shuo and Zhang, Chaofan and Wang, Rui and Zhang, Boyue and Zhang, Shaolin and Wang, Yu},
journal = {IEEE/ASME Transactions on Mechatronics},
year = {2023},
volume = {29},
number = {4},
pages = {2451--2462},
doi = {10.1109/tmech.2023.3336335},
url = {https://doi.org/10.1109/tmech.2023.3336335}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Citations by year
| Year | Citations | Share of the best year |
|---|---|---|
| 2024 | 1 | |
| 2025 | 8 | |
| 2026 | 7 |
Its field-weighted citation impact is 1.26: it has been cited 1.26 times as often as the average work of the same field, type and year (1.00 is the world average).
Topic and keywords
Physical Sciences › Engineering › Control and Systems Engineering › Robot Manipulation and Learning
- soft sensors
- stereo vision
- self-calibration
- robotic manipulation
- dexterous robotic hand
- biomimetic sensors
- shape measurement
Work with this paper
Most-cited papers in Engineering
- A Closed‐form Equation for Predicting the Hydraulic Conductivity of Unsaturated SoilsMartinus Th. van Genuchten · Soil Science Society of America Journal · 1980 · 28,197 citations
- An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experimentsW. C. Oliver, George M. Pharr · Journal of materials research/Pratt's guide to venture capital sources · 1992 · 27,379 citations
- Digital communicationsOwen Bishop · Routledge eBooks · 2007 · 24,890 citations
- The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysisNorden Eh Huang, Zhengwei Shen, Steven R. Long and 6 more · Proceedings of the Royal Society A Mathematical Physical and Engineering Sciences · 1998 · 24,008 citations
- Numerical Heat Transfer and Fluid FlowSuhas V. Patankar · CRC Press eBooks · 2018 · 23,491 citations
Questions about this paper
How do I cite this paper in APA style?
Cui, S., Wang, S., Zhang, C., Wang, R., Zhang, B., Zhang, S., & Wang, Y. (2023). GelStereo BioTip: Self-Calibrating Bionic Fingertip Visuotactile Sensor for Robotic Manipulation. IEEE/ASME Transactions on Mechatronics, 29(4), 2451–2462. https://doi.org/10.1109/tmech.2023.3336335
How many times has this paper been cited?
16 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
OpenAlex records no free legal copy. Check your library's access, the authors' pages or a repository, or ask the corresponding author for a copy.
Who wrote this paper?
Shaowei Cui, Shuo Wang, Chaofan Zhang, Rui Wang, Boyue Zhang, Shaolin Zhang, Yu Wang.
What is the DOI of this paper?
10.1109/tmech.2023.3336335, permanently at https://doi.org/10.1109/tmech.2023.3336335. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.