Journal article · 2026
Force Estimation With Concentric-Tube Robots for Surgical Palpation
IEEE Robotics and Automation Letters, 11(7), 8896–8903 · Published 8 June 2026 · DOI 10.1109/lra.2026.3701528
In brief
“Force Estimation With Concentric-Tube Robots for Surgical Palpation” is a 2026 journal article by Yufei Wu and 4 co-authors, published in IEEE Robotics and Automation Letters. OpenAlex counts 0 citations as of 26 November 2026. The publisher's version is not open access, and OpenAlex records no free legal copy.
- Citations
- 0
- References
- 25
- Authors
- 5
Abstract
This paper presents the design, modeling, and experimental verification of a deflection-based force-sensing probe in a concentric-tube robot for palpation during robotic surgery. The proposed method leverages the inherent elastic compliance of the robot and a quasi-static Cosserat rod model to estimate contact forces from real-time tip deflections measured by a 5-DOF magnetic tracker, eliminating… Read the full abstract at the publisher.
Excerpt. This paper is not open access.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Wu, Y., Gaston, J., Tobin, S., Branscombe, L., & Rucker, D. C. (2026). Force Estimation With Concentric-Tube Robots for Surgical Palpation. IEEE Robotics and Automation Letters, 11(7), 8896–8903. https://doi.org/10.1109/lra.2026.3701528
MLA 9
Wu, Yufei, et al. “Force Estimation With Concentric-Tube Robots for Surgical Palpation.” IEEE Robotics and Automation Letters, vol. 11, no. 7, 2026, pp. 8896–8903. https://doi.org/10.1109/lra.2026.3701528.
Chicago
Wu, Yufei, Joshua Gaston, Samuel Tobin, Lauren Branscombe, and D. Caleb Rucker. 2026. “Force Estimation With Concentric-Tube Robots for Surgical Palpation.” IEEE Robotics and Automation Letters 11 (7): 8896–8903. https://doi.org/10.1109/lra.2026.3701528.
Harvard
Wu, Y. et al. (2026) ‘Force Estimation With Concentric-Tube Robots for Surgical Palpation’, IEEE Robotics and Automation Letters, 11(7), pp. 8896–8903. doi:10.1109/lra.2026.3701528.
IEEE
Y. Wu, J. Gaston, S. Tobin, L. Branscombe, and D. C. Rucker, “Force Estimation With Concentric-Tube Robots for Surgical Palpation,” IEEE Robotics and Automation Letters, vol. 11, no. 7, pp. 8896–8903, 2026, doi: 10.1109/lra.2026.3701528.
BibTeX
@article{wu2026force,
title = {{Force Estimation With Concentric-Tube Robots for Surgical Palpation}},
author = {Wu, Yufei and Gaston, Joshua and Tobin, Samuel and Branscombe, Lauren and Rucker, D. Caleb},
journal = {IEEE Robotics and Automation Letters},
year = {2026},
volume = {11},
number = {7},
pages = {8896--8903},
doi = {10.1109/lra.2026.3701528},
url = {https://doi.org/10.1109/lra.2026.3701528}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Topic and keywords
Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- force estimation
- concentric tube robots
- robotic palpation
- Cosserat rod model
- elastic compliance
- contact force estimation
- tissue stiffness mapping
- continuum robots
Work with this paper
Most-cited papers in Engineering
- A Closed‐form Equation for Predicting the Hydraulic Conductivity of Unsaturated SoilsMartinus Th. van Genuchten · Soil Science Society of America Journal · 1980 · 28,197 citations
- An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experimentsW. C. Oliver, George M. Pharr · Journal of materials research/Pratt's guide to venture capital sources · 1992 · 27,379 citations
- Digital communicationsOwen Bishop · Routledge eBooks · 2007 · 24,890 citations
- The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysisNorden Eh Huang, Zhengwei Shen, Steven R. Long and 6 more · Proceedings of the Royal Society A Mathematical Physical and Engineering Sciences · 1998 · 24,008 citations
- Numerical Heat Transfer and Fluid FlowSuhas V. Patankar · CRC Press eBooks · 2018 · 23,491 citations
Questions about this paper
How do I cite this paper in APA style?
Wu, Y., Gaston, J., Tobin, S., Branscombe, L., & Rucker, D. C. (2026). Force Estimation With Concentric-Tube Robots for Surgical Palpation. IEEE Robotics and Automation Letters, 11(7), 8896–8903. https://doi.org/10.1109/lra.2026.3701528
How many times has this paper been cited?
0 times, according to OpenAlex on 26 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
OpenAlex records no free legal copy. Check your library's access, the authors' pages or a repository, or ask the corresponding author for a copy.
Who wrote this paper?
Yufei Wu, Joshua Gaston, Samuel Tobin, Lauren Branscombe, D. Caleb Rucker.
What is the DOI of this paper?
10.1109/lra.2026.3701528, permanently at https://doi.org/10.1109/lra.2026.3701528. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 26 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.