Journal article · 2022 · Open access

Feasibility of wireless continuous monitoring of vital signs without using alarms on a general surgical ward: A mixed methods study

Jobbe P L Leenen, Henriëtte J M Rasing, Joris David van Dijk, Cor J. Kalkman, Lisette Schoonhoven, Gijs A. Patijn

PLoS ONE, 17(3), e0265435 · Published 14 March 2022 · DOI 10.1371/journal.pone.0265435

Open PDFView at the publisherCite this paper

In brief

“Feasibility of wireless continuous monitoring of vital signs without using alarms on a general surgical ward: A mixed methods study” is a 2022 journal article by Jobbe P L Leenen and 5 co-authors, published in PLoS ONE. OpenAlex counts 39 citations as of 21 November 2026, which puts it in the top 2% of works published in 2022 by citations. It is open access under a CC BY licence: the full text is free to read at PLoS ONE.

Citations
39
Most cited in
2023 (11)
Field-weighted impact
6.15
References
48
Authors
6

Abstract

BACKGROUND: Wireless continuous vital sign monitoring by wearable devices have recently become available for patients on general wards to promote timely detection of clinical deterioration. Many continuous monitoring systems use conventional threshold alarm settings to alert nurses in case of deviating vital signs. However, frequent false alarms often lead to alarm fatigue and inefficiencies in the workplace. The aim of this study was to determine the feasibility of continuous vital sign monitoring without the use of alarms, thereby exclusively relying on interval trend monitoring. METHODS: This explanatory sequential mixed methods study was conducted at an abdominal surgical ward of a tertiary teaching hospital. Heart rate and respiratory rate of patients were measured every minute by a wearable sensor. Trends were visualized and assessed six times per day by nurses and once a day by doctors during morning rounds. Instead of using alarms we focused exclusively on regular vital sign trend analysis by nurses and doctors. Primary outcome was feasibility in terms of acceptability by professionals, assessed by the Usefulness, Satisfaction and Ease of Use questionnaire and further explored in two focus groups, as well as fidelity. RESULTS: A total of 56 patients were monitored and in 80.5% (n = 536) of nurses' work shifts the trends assessments were documented. All deviating trends (n = 17) were recognized in time. Professionals (N = 46) considered continuous monitoring satisfying (4.8±1.0 on a 1-7 Likert-scale) and were willing to use the technology. Although insight into vital sign trends allowed faster anticipation and action upon changed patient status, professionals were neutral about usefulness (4.4±1.0). They found continuous monitoring easy to use (4.7±0.8) and easy to learn (5.3±1.0) but indicated the need for gaining practical experience. Nurses considered the use of alarms for deviating vital signs unnecessary, when trends were regularly assessed and reported. CONCLUSION: We demonstrated that continuous vital signs trend monitoring without using alarms was feasible in the general ward setting, thereby avoiding unnecessary alarms and preventing alarm fatigue. When monitoring in a general ward setting, the standard use of alarms may therefore be reconsidered.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Leenen, J. P. L., Rasing, H. J. M., van Dijk, J. D., Kalkman, C. J., Schoonhoven, L., & Patijn, G. A. (2022). Feasibility of wireless continuous monitoring of vital signs without using alarms on a general surgical ward: A mixed methods study. PLoS ONE, 17(3), e0265435. https://doi.org/10.1371/journal.pone.0265435

MLA 9

Leenen, Jobbe P L, et al. “Feasibility of wireless continuous monitoring of vital signs without using alarms on a general surgical ward: A mixed methods study.” PLoS ONE, vol. 17, no. 3, 2022, p. e0265435. https://doi.org/10.1371/journal.pone.0265435.

Chicago

Leenen, Jobbe P L, Henriëtte J M Rasing, Joris David van Dijk, Cor J. Kalkman, Lisette Schoonhoven, and Gijs A. Patijn. 2022. “Feasibility of wireless continuous monitoring of vital signs without using alarms on a general surgical ward: A mixed methods study.” PLoS ONE 17 (3): e0265435. https://doi.org/10.1371/journal.pone.0265435.

Harvard

Leenen, J. P. L. et al. (2022) ‘Feasibility of wireless continuous monitoring of vital signs without using alarms on a general surgical ward: A mixed methods study’, PLoS ONE, 17(3), p. e0265435. doi:10.1371/journal.pone.0265435.

IEEE

J. P. L. Leenen, H. J. M. Rasing, J. D. van Dijk, C. J. Kalkman, L. Schoonhoven, and G. A. Patijn, “Feasibility of wireless continuous monitoring of vital signs without using alarms on a general surgical ward: A mixed methods study,” PLoS ONE, vol. 17, no. 3, p. e0265435, 2022, doi: 10.1371/journal.pone.0265435.

BibTeX

@article{leenen2022feasibility,
  title     = {{Feasibility of wireless continuous monitoring of vital signs without using alarms on a general surgical ward: A mixed methods study}},
  author    = {Leenen, Jobbe P L and Rasing, Henriëtte J M and van Dijk, Joris David and Kalkman, Cor J. and Schoonhoven, Lisette and Patijn, Gijs A.},
  journal   = {PLoS ONE},
  year      = {2022},
  volume    = {17},
  number    = {3},
  pages     = {e0265435},
  doi       = {10.1371/journal.pone.0265435},
  url       = {https://doi.org/10.1371/journal.pone.0265435}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
20231111
20241111
20251010
202677

Its field-weighted citation impact is 6.15: it has been cited 6.15 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring

  • continuous vital sign monitoring
  • wearable sensors
  • alarm fatigue
  • clinical deterioration detection
  • general surgical ward
  • feasibility
  • heart rate
  • respiratory rate

Work with this paper

Most-cited papers in Medicine

All highly cited Medicine papers

Questions about this paper

How do I cite this paper in APA style?

Leenen, J. P. L., Rasing, H. J. M., van Dijk, J. D., Kalkman, C. J., Schoonhoven, L., & Patijn, G. A. (2022). Feasibility of wireless continuous monitoring of vital signs without using alarms on a general surgical ward: A mixed methods study. PLoS ONE, 17(3), e0265435. https://doi.org/10.1371/journal.pone.0265435

How many times has this paper been cited?

39 times, according to OpenAlex on 21 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at PLoS ONE: sign in and open the PDF from this page.

Who wrote this paper?

Jobbe P L Leenen, Henriëtte J M Rasing, Joris David van Dijk, Cor J. Kalkman, Lisette Schoonhoven, Gijs A. Patijn.

What is the DOI of this paper?

10.1371/journal.pone.0265435, permanently at https://doi.org/10.1371/journal.pone.0265435. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 21 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.