Journal article · 2024 · Open access
Evaluation of Cyclic Fatigue Resistance of Novel Replica‐Like Instruments in Static Test Model
Applied Bionics and Biomechanics, 2024(1), 8842478 · Published 1 January 2024 · DOI 10.1155/2024/8842478
In brief
“Evaluation of Cyclic Fatigue Resistance of Novel Replica‐Like Instruments in Static Test Model” is a 2024 journal article by Uğur Aydın and 4 co-authors, published in Applied Bionics and Biomechanics. OpenAlex counts 6 citations as of 22 November 2026. It is open access under a CC BY licence: the full text is free to read at Applied Bionics and Biomechanics.
- Citations
- 6
- Most cited in
- 2026 (5)
- Field-weighted impact
- 1.72
- References
- 39
- Authors
- 5
Abstract
Introduction: The aim of our study is to comparatively analyze the canal cyclic fatigue resistance of widely used rotary file systems, including EndoArt Touch Gold (ETG), Perfect MTF Plus Gold (PPG), Fanta V-Taper Gold (FVG), and ProTaper Next (PTN). Methods: Stainless steel canals with a 60° angle and a 3-mm curvature radius were specially prepared. The canals were shaped with each rotary file system and tested for resistance using a cyclic fatigue testing apparatus. The number of fracture cycles (NFC; K file tip separation) was measured. Data were analysed by one-way ANOVA and post hoc LSD tests. Results: PTN and PPG rotary file systems exhibited the highest NFC. The NFC value for PTN was 589 ± 63, and for PPG, it was 507 ± 51. Conclusion: The results of this study demonstrate that rotary file systems such as PTN and PPG exhibit higher cyclic fatigue resistance. ETG and FVG rotary file systems also possess generally acceptable cyclic fatigue resistance levels.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Aydın, U., Özdemir, M., Çulha, E., Baştürk, M. N., & Turan, B. (2024). Evaluation of Cyclic Fatigue Resistance of Novel Replica‐Like Instruments in Static Test Model. Applied Bionics and Biomechanics, 2024(1), 8842478. https://doi.org/10.1155/2024/8842478
MLA 9
Aydın, Uğur, et al. “Evaluation of Cyclic Fatigue Resistance of Novel Replica‐Like Instruments in Static Test Model.” Applied Bionics and Biomechanics, vol. 2024, no. 1, 2024, p. 8842478. https://doi.org/10.1155/2024/8842478.
Chicago
Aydın, Uğur, Melih Özdemir, Emre Çulha, Muazzez Naz Baştürk, and Bilal Turan. 2024. “Evaluation of Cyclic Fatigue Resistance of Novel Replica‐Like Instruments in Static Test Model.” Applied Bionics and Biomechanics 2024 (1): 8842478. https://doi.org/10.1155/2024/8842478.
Harvard
Aydın, U. et al. (2024) ‘Evaluation of Cyclic Fatigue Resistance of Novel Replica‐Like Instruments in Static Test Model’, Applied Bionics and Biomechanics, 2024(1), p. 8842478. doi:10.1155/2024/8842478.
IEEE
U. Aydın, M. Özdemir, E. Çulha, M. N. Baştürk, and B. Turan, “Evaluation of Cyclic Fatigue Resistance of Novel Replica‐Like Instruments in Static Test Model,” Applied Bionics and Biomechanics, vol. 2024, no. 1, p. 8842478, 2024, doi: 10.1155/2024/8842478.
BibTeX
@article{aydn2024evaluation,
title = {{Evaluation of Cyclic Fatigue Resistance of Novel Replica‐Like Instruments in Static Test Model}},
author = {Aydın, Uğur and Özdemir, Melih and Çulha, Emre and Baştürk, Muazzez Naz and Turan, Bilal},
journal = {Applied Bionics and Biomechanics},
year = {2024},
volume = {2024},
number = {1},
pages = {8842478},
doi = {10.1155/2024/8842478},
url = {https://doi.org/10.1155/2024/8842478}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Topic and keywords
Health Sciences › Dentistry › Oral Surgery › Endodontics and Root Canal Treatments
- cyclic fatigue resistance
- rotary file systems
- root canal instrumentation
- ProTaper Next
- canal curvature
Work with this paper
Most-cited papers in Dentistry
- Periodontal Disease in Pregnancy II. Correlation Between Oral Hygiene and Periodontal ConditionJohn Silness, Harald A. Löe · Acta Odontologica Scandinavica · 1964 · 8,071 citations
- Periodontal Disease in Pregnancy I. Prevalence and SeverityHarald A. Löe, John Silness · Acta Odontologica Scandinavica · 1963 · 7,339 citations
- Microbial complexes in subgingival plaqueS. S. Socransky, Anne D. Haffajee, MaryAnn Cugini and 2 more · Journal Of Clinical Periodontology · 1998 · 5,207 citations
- Development of a Classification System for Periodontal Diseases and ConditionsGary C. Armitage · Annals of Periodontology · 1999 · 5,198 citations
- Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for Clinical and Research Applications: Recommendations of the International RDC/TMD Consortium Network* and Orofacial Pain Special Interest Group†ERIC L. SCHIFFMAN, Richard K. Ohrbach, Edmond L. Truelove and 27 more · Journal of Oral & Facial Pain and Headache · 2014 · 4,942 citations
Questions about this paper
How do I cite this paper in APA style?
Aydın, U., Özdemir, M., Çulha, E., Baştürk, M. N., & Turan, B. (2024). Evaluation of Cyclic Fatigue Resistance of Novel Replica‐Like Instruments in Static Test Model. Applied Bionics and Biomechanics, 2024(1), 8842478. https://doi.org/10.1155/2024/8842478
How many times has this paper been cited?
6 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at Applied Bionics and Biomechanics: sign in and open the PDF from this page.
Who wrote this paper?
Uğur Aydın, Melih Özdemir, Emre Çulha, Muazzez Naz Baştürk, Bilal Turan.
What is the DOI of this paper?
10.1155/2024/8842478, permanently at https://doi.org/10.1155/2024/8842478. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.