Journal article · 2006 · Open access

Electron Probe Microanalysis of Li K-alpha with Newly Developed Ultra-Soft X-ray Spectrometer

Sei Fukushima, Takashi Kimura, Toshiya Ogiwara, Kazunori Tsukamoto, Toyohiko Tazawa, Shigeo Tanuma

Microscopy and Microanalysis, 12(S02), 872–873 · Published 31 July 2006 · DOI 10.1017/s1431927606062453

Free PDFView at the publisherCite this paper

In brief

“Electron Probe Microanalysis of Li K-alpha with Newly Developed Ultra-Soft X-ray Spectrometer” is a 2006 journal article by Sei Fukushima and 5 co-authors, published in Microscopy and Microanalysis. OpenAlex counts 2 citations as of 16 November 2026. It is open access: the full text is free to read at Microscopy and Microanalysis.

Citations
2
Most cited in
2023 (1)
Authors
6

Abstract

Recently, Li has been much attention to the various industrial fields as an important element.For example, LiNbO 3 or LiTaO 3 is one of the most important compounds because of its various optical characteristic and ferroelectrics.It is well known that LiCO 3 shows the drastic effect as a anti-depressant drag.Thus, it can be said that the necessity of the chemical state analysis for Li has been increased so much.However, Li is also well known as the one of the most difficult elements for analysis.This group has already developed the general-purpose electron beam excitation ultra-soft X-ray analyzer with new designed high-resolution flat-field VLS(Varied-Line-Spacing) grating spectrometer.The schematic view is shown in Fig. 1.In this report, the preliminary results of the measurement of Li Kα for metallic Li and some Li compounds are presented.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Fukushima, S., Kimura, T., Ogiwara, T., Tsukamoto, K., Tazawa, T., & Tanuma, S. (2006). Electron Probe Microanalysis of Li K-alpha with Newly Developed Ultra-Soft X-ray Spectrometer. Microscopy and Microanalysis, 12(S02), 872–873. https://doi.org/10.1017/s1431927606062453

MLA 9

Fukushima, Sei, et al. “Electron Probe Microanalysis of Li K-alpha with Newly Developed Ultra-Soft X-ray Spectrometer.” Microscopy and Microanalysis, vol. 12, no. S02, 2006, pp. 872–873. https://doi.org/10.1017/s1431927606062453.

Chicago

Fukushima, Sei, Takashi Kimura, Toshiya Ogiwara, Kazunori Tsukamoto, Toyohiko Tazawa, and Shigeo Tanuma. 2006. “Electron Probe Microanalysis of Li K-alpha with Newly Developed Ultra-Soft X-ray Spectrometer.” Microscopy and Microanalysis 12 (S02): 872–873. https://doi.org/10.1017/s1431927606062453.

Harvard

Fukushima, S. et al. (2006) ‘Electron Probe Microanalysis of Li K-alpha with Newly Developed Ultra-Soft X-ray Spectrometer’, Microscopy and Microanalysis, 12(S02), pp. 872–873. doi:10.1017/s1431927606062453.

IEEE

S. Fukushima, T. Kimura, T. Ogiwara, K. Tsukamoto, T. Tazawa, and S. Tanuma, “Electron Probe Microanalysis of Li K-alpha with Newly Developed Ultra-Soft X-ray Spectrometer,” Microscopy and Microanalysis, vol. 12, no. S02, pp. 872–873, 2006, doi: 10.1017/s1431927606062453.

BibTeX

@article{fukushima2006electron,
  title     = {{Electron Probe Microanalysis of Li K-alpha with Newly Developed Ultra-Soft X-ray Spectrometer}},
  author    = {Fukushima, Sei and Kimura, Takashi and Ogiwara, Toshiya and Tsukamoto, Kazunori and Tazawa, Toyohiko and Tanuma, Shigeo},
  journal   = {Microscopy and Microanalysis},
  year      = {2006},
  volume    = {12},
  number    = {S02},
  pages     = {872--873},
  doi       = {10.1017/s1431927606062453},
  url       = {https://doi.org/10.1017/s1431927606062453}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Physical Sciences › Physics and Astronomy › Radiation › X-ray Spectroscopy and Fluorescence Analysis

  • lithium
  • electron probe microanalysis
  • chemical state analysis
  • lithium compounds
  • metallic lithium

Work with this paper

Most-cited papers in Physics and Astronomy

All highly cited Physics and Astronomy papers

Questions about this paper

How do I cite this paper in APA style?

Fukushima, S., Kimura, T., Ogiwara, T., Tsukamoto, K., Tazawa, T., & Tanuma, S. (2006). Electron Probe Microanalysis of Li K-alpha with Newly Developed Ultra-Soft X-ray Spectrometer. Microscopy and Microanalysis, 12(S02), 872–873. https://doi.org/10.1017/s1431927606062453

How many times has this paper been cited?

2 times, according to OpenAlex on 16 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access: read the free full text at Microscopy and Microanalysis.

Who wrote this paper?

Sei Fukushima, Takashi Kimura, Toshiya Ogiwara, Kazunori Tsukamoto, Toyohiko Tazawa, Shigeo Tanuma.

What is the DOI of this paper?

10.1017/s1431927606062453. The permanent link is https://doi.org/10.1017/s1431927606062453.

Bibliographic data from OpenAlex (CC0), last checked 16 November 2026. ResearchGuru does not host this paper; the links go to the publisher or the repository that does.