Journal article · 2016 · Open access

Electrochemical Corrosion Behavior of Ta2N Nanoceramic Coating in Simulated Body Fluid

Jian Bing Cheng, Jiang Xu, Lin Liu, Shuyun Jiang

Materials, 9(9), 772 · Published 10 September 2016 · DOI 10.3390/ma9090772

Open PDFView at the publisherCite this paper

In brief

“Electrochemical Corrosion Behavior of Ta2N Nanoceramic Coating in Simulated Body Fluid” is a 2016 journal article by Jian Bing Cheng and 3 co-authors, published in Materials. OpenAlex counts 34 citations as of 17 November 2026. It is open access under a CC BY licence: the full text is free to read at Materials.

Citations
34
Most cited in
2020 (6)
Field-weighted impact
0.61
References
59
Authors
4

Abstract

In order to improve the corrosion and wear resistance of biomedical Ti-6Al-4V implants, a Ta2N nanoceramic coating was synthesized on a Ti-6Al-4V substrate by the double glow discharge plasma process. The Ta2N coating, composed of fine nanocrystals, with an average grain size of 12.8 nm, improved the surface hardness of Ti-6Al-4V and showed good contact damage tolerance and good adhesion strength to the substrate. The corrosion resistance of the Ta2N coating in Ringer’s physiological solution at 37 °C was evaluated by different electrochemical techniques: potentiodynamic polarization, electrochemical impedance spectroscopy (EIS), potentiostatic polarization and capacitance measurements (Mott-Schottky approach). The evolution of the surface composition of the passive films at different applied potentials was determined by X-ray photoelectron spectroscopy (XPS). The results indicated that the Ta2N coating showed higher corrosion resistance than both commercially pure Ta and uncoated Ti-6Al-4V in this solution, because of the formed oxide film on the Ta2N coating having a smaller carrier density (Nd) and diffusivity (Do) of point defects. The composition of the surface passive film formed on the Ta2N coating changed with the applied potential. At low applied potentials, the oxidation of the Ta2N coating led to the formation of tantalum oxynitride (TaOxNy) but, subsequently, the tantalum oxynitride (TaOxNy) could be chemically converted to Ta2O5 at higher applied potentials.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Cheng, J. B., Xu, J., Liu, L., & Jiang, S. (2016). Electrochemical Corrosion Behavior of Ta2N Nanoceramic Coating in Simulated Body Fluid. Materials, 9(9), 772. https://doi.org/10.3390/ma9090772

MLA 9

Cheng, Jian Bing, et al. “Electrochemical Corrosion Behavior of Ta2N Nanoceramic Coating in Simulated Body Fluid.” Materials, vol. 9, no. 9, 2016, p. 772. https://doi.org/10.3390/ma9090772.

Chicago

Cheng, Jian Bing, Jiang Xu, Lin Liu, and Shuyun Jiang. 2016. “Electrochemical Corrosion Behavior of Ta2N Nanoceramic Coating in Simulated Body Fluid.” Materials 9 (9): 772. https://doi.org/10.3390/ma9090772.

Harvard

Cheng, J. B. et al. (2016) ‘Electrochemical Corrosion Behavior of Ta2N Nanoceramic Coating in Simulated Body Fluid’, Materials, 9(9), p. 772. doi:10.3390/ma9090772.

IEEE

J. B. Cheng, J. Xu, L. Liu, and S. Jiang, “Electrochemical Corrosion Behavior of Ta2N Nanoceramic Coating in Simulated Body Fluid,” Materials, vol. 9, no. 9, p. 772, 2016, doi: 10.3390/ma9090772.

BibTeX

@article{cheng2016electrochemical,
  title     = {{Electrochemical Corrosion Behavior of Ta2N Nanoceramic Coating in Simulated Body Fluid}},
  author    = {Cheng, Jian Bing and Xu, Jiang and Liu, Lin and Jiang, Shuyun},
  journal   = {Materials},
  year      = {2016},
  volume    = {9},
  number    = {9},
  pages     = {772},
  doi       = {10.3390/ma9090772},
  url       = {https://doi.org/10.3390/ma9090772}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
201822
201933
202066
202155
202255
202333
202411
202544
202655

Its field-weighted citation impact is 0.61: it has been cited 0.61 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Physical Sciences › Materials Science › Materials Chemistry › Titanium Alloys Microstructure and Properties

  • Ti6Al4V implants
  • simulated body fluid
  • corrosion resistance
  • tantalum nitride
  • passive film
  • tantalum oxynitride
  • carrier concentration
  • Mott-Schottky analysis

Work with this paper

Most-cited papers in Materials Science

All highly cited Materials Science papers

Questions about this paper

How do I cite this paper in APA style?

Cheng, J. B., Xu, J., Liu, L., & Jiang, S. (2016). Electrochemical Corrosion Behavior of Ta2N Nanoceramic Coating in Simulated Body Fluid. Materials, 9(9), 772. https://doi.org/10.3390/ma9090772

How many times has this paper been cited?

34 times, according to OpenAlex on 17 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Materials: sign in and open the PDF from this page.

Who wrote this paper?

Jian Bing Cheng, Jiang Xu, Lin Liu, Shuyun Jiang.

What is the DOI of this paper?

10.3390/ma9090772, permanently at https://doi.org/10.3390/ma9090772. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 17 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.