“Electrochemical Corrosion Behavior of Ta2N Nanoceramic Coating in Simulated Body Fluid” is a 2016 journal article by Jian Bing Cheng and 3 co-authors, published in Materials. OpenAlex counts 34 citations as of 17 November 2026. It is open access under a CC BY licence: the full text is free to read at Materials.
- Citations
- 34
- Most cited in
- 2020 (6)
- Field-weighted impact
- 0.61
- References
- 59
- Authors
- 4
Abstract
In order to improve the corrosion and wear resistance of biomedical Ti-6Al-4V implants, a Ta2N nanoceramic coating was synthesized on a Ti-6Al-4V substrate by the double glow discharge plasma process. The Ta2N coating, composed of fine nanocrystals, with an average grain size of 12.8 nm, improved the surface hardness of Ti-6Al-4V and showed good contact damage tolerance and good adhesion strength to the substrate. The corrosion resistance of the Ta2N coating in Ringer’s physiological solution at 37 °C was evaluated by different electrochemical techniques: potentiodynamic polarization, electrochemical impedance spectroscopy (EIS), potentiostatic polarization and capacitance measurements (Mott-Schottky approach). The evolution of the surface composition of the passive films at different applied potentials was determined by X-ray photoelectron spectroscopy (XPS). The results indicated that the Ta2N coating showed higher corrosion resistance than both commercially pure Ta and uncoated Ti-6Al-4V in this solution, because of the formed oxide film on the Ta2N coating having a smaller carrier density (Nd) and diffusivity (Do) of point defects. The composition of the surface passive film formed on the Ta2N coating changed with the applied potential. At low applied potentials, the oxidation of the Ta2N coating led to the formation of tantalum oxynitride (TaOxNy) but, subsequently, the tantalum oxynitride (TaOxNy) could be chemically converted to Ta2O5 at higher applied potentials.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Cheng, J. B., Xu, J., Liu, L., & Jiang, S. (2016). Electrochemical Corrosion Behavior of Ta2N Nanoceramic Coating in Simulated Body Fluid. Materials, 9(9), 772. https://doi.org/10.3390/ma9090772
MLA 9
Cheng, Jian Bing, et al. “Electrochemical Corrosion Behavior of Ta2N Nanoceramic Coating in Simulated Body Fluid.” Materials, vol. 9, no. 9, 2016, p. 772. https://doi.org/10.3390/ma9090772.
Chicago
Cheng, Jian Bing, Jiang Xu, Lin Liu, and Shuyun Jiang. 2016. “Electrochemical Corrosion Behavior of Ta2N Nanoceramic Coating in Simulated Body Fluid.” Materials 9 (9): 772. https://doi.org/10.3390/ma9090772.
Harvard
Cheng, J. B. et al. (2016) ‘Electrochemical Corrosion Behavior of Ta2N Nanoceramic Coating in Simulated Body Fluid’, Materials, 9(9), p. 772. doi:10.3390/ma9090772.
IEEE
J. B. Cheng, J. Xu, L. Liu, and S. Jiang, “Electrochemical Corrosion Behavior of Ta2N Nanoceramic Coating in Simulated Body Fluid,” Materials, vol. 9, no. 9, p. 772, 2016, doi: 10.3390/ma9090772.
BibTeX
@article{cheng2016electrochemical,
title = {{Electrochemical Corrosion Behavior of Ta2N Nanoceramic Coating in Simulated Body Fluid}},
author = {Cheng, Jian Bing and Xu, Jiang and Liu, Lin and Jiang, Shuyun},
journal = {Materials},
year = {2016},
volume = {9},
number = {9},
pages = {772},
doi = {10.3390/ma9090772},
url = {https://doi.org/10.3390/ma9090772}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Citations by year
| Year | Citations | Share of the best year |
|---|---|---|
| 2018 | 2 | |
| 2019 | 3 | |
| 2020 | 6 | |
| 2021 | 5 | |
| 2022 | 5 | |
| 2023 | 3 | |
| 2024 | 1 | |
| 2025 | 4 | |
| 2026 | 5 |
Its field-weighted citation impact is 0.61: it has been cited 0.61 times as often as the average work of the same field, type and year (1.00 is the world average).
Topic and keywords
Physical Sciences › Materials Science › Materials Chemistry › Titanium Alloys Microstructure and Properties
- Ti6Al4V implants
- simulated body fluid
- corrosion resistance
- tantalum nitride
- passive film
- tantalum oxynitride
- carrier concentration
- Mott-Schottky analysis
Work with this paper
Most-cited papers in Materials Science
- Electric Field Effect in Atomically Thin Carbon FilmsKostya S. Novoselov, Andre K. Geim, Sergey V. Morozov and 5 more · Science · 2004 · 67,474 citations
- Revised effective ionic radii and systematic studies of interatomic distances in halides and chalcogenidesROBERT D. SHANNON · Acta Crystallographica Section A · 1976 · 66,944 citations
- Ab initio molecular dynamics for liquid metalsGeorg Kresse, J. Häfner · Physical review. B, Condensed matter · 1993 · 46,320 citations
- Helical microtubules of graphitic carbonSumio Iijima · Nature · 1991 · 43,639 citations
- The rise of grapheneAndre K. Geim, Kostya S. Novoselov · Nature Materials · 2007 · 40,328 citations
Questions about this paper
How do I cite this paper in APA style?
Cheng, J. B., Xu, J., Liu, L., & Jiang, S. (2016). Electrochemical Corrosion Behavior of Ta2N Nanoceramic Coating in Simulated Body Fluid. Materials, 9(9), 772. https://doi.org/10.3390/ma9090772
How many times has this paper been cited?
34 times, according to OpenAlex on 17 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at Materials: sign in and open the PDF from this page.
Who wrote this paper?
Jian Bing Cheng, Jiang Xu, Lin Liu, Shuyun Jiang.
What is the DOI of this paper?
10.3390/ma9090772, permanently at https://doi.org/10.3390/ma9090772. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 17 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.