Journal article · 2020 · Open access

Electrochemical behavior of TiN, CrN and TiN/CrN nanostructured coatings on the nickel-chromium alloy used in dental fixed prosthesis

Nidhal Sahib Mansoor, Arash Fattah‐alhosseini, Hassan Elmkhah, Arash Shishehian

Journal of Asian Ceramic Societies, 8(3), 694–710 · Published 12 June 2020 · DOI 10.1080/21870764.2020.1776915

Open PDFView at the publisherCite this paper

In brief

“Electrochemical behavior of TiN, CrN and TiN/CrN nanostructured coatings on the nickel-chromium alloy used in dental fixed prosthesis” is a 2020 journal article by Nidhal Sahib Mansoor and 3 co-authors, published in Journal of Asian Ceramic Societies. OpenAlex counts 32 citations as of 19 November 2026, which puts it in the top 8% of works published in 2020 by citations. It is open access under a CC BY licence: the full text is free to read at Journal of Asian Ceramic Societies.

Citations
32
Most cited in
2023 (8)
Field-weighted impact
2.11
References
51
Authors
4

Abstract

The aim of this research is the evaluation of the influence of TiN, CrN and TiN/CrN nanostructured coatings on corrosion resistance of nickel-chromium dental alloy in artificial saliva environment with two pH levels (3.0 and 6.5). Nickel-chromium alloy tested in this study were more resistant to corrosion in artificial saliva conditioning media when coated with different types of coating materials, as compared to uncoated alloy. The electrochemical measurements propose that the alloy with CrN coating has shown a high corrosion resistance in different pH levels. The superior passivation of CrN monolayer coating in modified Fusayama artificial saliva solution may be concluded from two essential factors, passive range, and corrosion current density. The passive range is well-developed, while the corrosion current density is much lower if compared to the other groups. Also, the Nyquist and polarization plots reveal that TiN, CrN and TiN/CrN nanostructured coatings have an excellent corrosion resistance which is considered much higher if compared to the substrate. The values of corrosion current density for CrN nanostructured coating in artificial saliva environment with two pH levels of 3.0 and 6.5 were 1.373 × 10−8 and 5.416 × 10−8 A.cm−2, respectively that were the lowest corrosion current density values among the other samples.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Mansoor, N. S., Fattah‐alhosseini, A., Elmkhah, H., & Shishehian, A. (2020). Electrochemical behavior of TiN, CrN and TiN/CrN nanostructured coatings on the nickel-chromium alloy used in dental fixed prosthesis. Journal of Asian Ceramic Societies, 8(3), 694–710. https://doi.org/10.1080/21870764.2020.1776915

MLA 9

Mansoor, Nidhal Sahib, et al. “Electrochemical behavior of TiN, CrN and TiN/CrN nanostructured coatings on the nickel-chromium alloy used in dental fixed prosthesis.” Journal of Asian Ceramic Societies, vol. 8, no. 3, 2020, pp. 694–710. https://doi.org/10.1080/21870764.2020.1776915.

Chicago

Mansoor, Nidhal Sahib, Arash Fattah‐alhosseini, Hassan Elmkhah, and Arash Shishehian. 2020. “Electrochemical behavior of TiN, CrN and TiN/CrN nanostructured coatings on the nickel-chromium alloy used in dental fixed prosthesis.” Journal of Asian Ceramic Societies 8 (3): 694–710. https://doi.org/10.1080/21870764.2020.1776915.

Harvard

Mansoor, N. S. et al. (2020) ‘Electrochemical behavior of TiN, CrN and TiN/CrN nanostructured coatings on the nickel-chromium alloy used in dental fixed prosthesis’, Journal of Asian Ceramic Societies, 8(3), pp. 694–710. doi:10.1080/21870764.2020.1776915.

IEEE

N. S. Mansoor, A. Fattah‐alhosseini, H. Elmkhah, and A. Shishehian, “Electrochemical behavior of TiN, CrN and TiN/CrN nanostructured coatings on the nickel-chromium alloy used in dental fixed prosthesis,” Journal of Asian Ceramic Societies, vol. 8, no. 3, pp. 694–710, 2020, doi: 10.1080/21870764.2020.1776915.

BibTeX

@article{mansoor2020electrochemical,
  title     = {{Electrochemical behavior of TiN, CrN and TiN/CrN nanostructured coatings on the nickel-chromium alloy used in dental fixed prosthesis}},
  author    = {Mansoor, Nidhal Sahib and Fattah‐alhosseini, Arash and Elmkhah, Hassan and Shishehian, Arash},
  journal   = {Journal of Asian Ceramic Societies},
  year      = {2020},
  volume    = {8},
  number    = {3},
  pages     = {694--710},
  doi       = {10.1080/21870764.2020.1776915},
  url       = {https://doi.org/10.1080/21870764.2020.1776915}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
202022
202122
202255
202388
202444
202577
202644

Its field-weighted citation impact is 2.11: it has been cited 2.11 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Physical Sciences › Engineering › Mechanical Engineering › Surface Treatment and Coatings

  • TiN coating
  • CrN coatings
  • nanostructured coatings
  • nickel-chromium alloy
  • dental alloys
  • corrosion resistance
  • artificial saliva
  • pH effect

Work with this paper

Most-cited papers in Engineering

All highly cited Engineering papers

Questions about this paper

How do I cite this paper in APA style?

Mansoor, N. S., Fattah‐alhosseini, A., Elmkhah, H., & Shishehian, A. (2020). Electrochemical behavior of TiN, CrN and TiN/CrN nanostructured coatings on the nickel-chromium alloy used in dental fixed prosthesis. Journal of Asian Ceramic Societies, 8(3), 694–710. https://doi.org/10.1080/21870764.2020.1776915

How many times has this paper been cited?

32 times, according to OpenAlex on 19 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Journal of Asian Ceramic Societies: sign in and open the PDF from this page.

Who wrote this paper?

Nidhal Sahib Mansoor, Arash Fattah‐alhosseini, Hassan Elmkhah, Arash Shishehian.

What is the DOI of this paper?

10.1080/21870764.2020.1776915, permanently at https://doi.org/10.1080/21870764.2020.1776915. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 19 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.