Journal article · 2009 · Open access

Efficient Assay for Total Antioxidant Capacity in Human Plasma Using a 96-Well Microplate

Yasuhiro Kambayashi, Nguyễn Thanh Bình, Hiroki Asakura, Yuri Hibino, Yoshiaki Hitomi, Hiroyuki Nakamura, Keiki Ogino

Journal of Clinical Biochemistry and Nutrition, 44(1), 46–51 · Published 1 January 2009 · DOI 10.3164/jcbn.08-162

Open PDFView at the publisherCite this paper

In brief

“Efficient Assay for Total Antioxidant Capacity in Human Plasma Using a 96-Well Microplate” is a 2009 journal article by Yasuhiro Kambayashi and 6 co-authors, published in Journal of Clinical Biochemistry and Nutrition. OpenAlex counts 182 citations as of 27 November 2026, which puts it in the top 2% of works published in 2009 by citations. It is open access: the full text is free to read at Journal of Clinical Biochemistry and Nutrition.

Citations
182
Most cited in
2022 (30)
Field-weighted impact
2.59
References
71
Authors
7

Abstract

In the present study, we tried to establish an efficient assay for total antioxidant capacity (TAC) in human plasma using a 96-well microplate. TAC was assessed using lag time by antioxidants against the myoglobin-induced oxidation of 2,2'-azino-di(3-ethylbenzthiazoline-6-sulfonic acid (ABTS) with hydrogen peroxide, and expressed as Trolox equivalent. The linearity of the calibration curve with Trolox was maintained with the Trolox concentration range from 2.5 microM to 25 microM (R(2) = 0.997). The assay was applied to the measurement of TAC in healthy human plasma. Coefficient of variation in intraday assay was 2.4%. Difference was not observed in interday assay. Plasma TAC of men ((569 +/- 41) microM Trolox equivalent; n = 6) was higher than that of women ((430 +/- 28) microM Trolox equivalent; n = 4). After the vegetable juice was drunk for 1 week, the increase in plasma TAC was observed in almost all the volunteers. In summary, we developed the efficient assay for plasma TAC using a 96-well microplate.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Kambayashi, Y., Bình, N. T., Asakura, H., Hibino, Y., Hitomi, Y., Nakamura, H., & Ogino, K. (2009). Efficient Assay for Total Antioxidant Capacity in Human Plasma Using a 96-Well Microplate. Journal of Clinical Biochemistry and Nutrition, 44(1), 46–51. https://doi.org/10.3164/jcbn.08-162

MLA 9

Kambayashi, Yasuhiro, et al. “Efficient Assay for Total Antioxidant Capacity in Human Plasma Using a 96-Well Microplate.” Journal of Clinical Biochemistry and Nutrition, vol. 44, no. 1, 2009, pp. 46–51. https://doi.org/10.3164/jcbn.08-162.

Chicago

Kambayashi, Yasuhiro, Nguyễn Thanh Bình, Hiroki Asakura, Yuri Hibino, Yoshiaki Hitomi, Hiroyuki Nakamura, and Keiki Ogino. 2009. “Efficient Assay for Total Antioxidant Capacity in Human Plasma Using a 96-Well Microplate.” Journal of Clinical Biochemistry and Nutrition 44 (1): 46–51. https://doi.org/10.3164/jcbn.08-162.

Harvard

Kambayashi, Y. et al. (2009) ‘Efficient Assay for Total Antioxidant Capacity in Human Plasma Using a 96-Well Microplate’, Journal of Clinical Biochemistry and Nutrition, 44(1), pp. 46–51. doi:10.3164/jcbn.08-162.

IEEE

Y. Kambayashi et al., “Efficient Assay for Total Antioxidant Capacity in Human Plasma Using a 96-Well Microplate,” Journal of Clinical Biochemistry and Nutrition, vol. 44, no. 1, pp. 46–51, 2009, doi: 10.3164/jcbn.08-162.

BibTeX

@article{kambayashi2009efficient,
  title     = {{Efficient Assay for Total Antioxidant Capacity in Human Plasma Using a 96-Well Microplate}},
  author    = {Kambayashi, Yasuhiro and Bình, Nguyễn Thanh and Asakura, Hiroki and Hibino, Yuri and Hitomi, Yoshiaki and Nakamura, Hiroyuki and Ogino, Keiki},
  journal   = {Journal of Clinical Biochemistry and Nutrition},
  year      = {2009},
  volume    = {44},
  number    = {1},
  pages     = {46--51},
  doi       = {10.3164/jcbn.08-162},
  url       = {https://doi.org/10.3164/jcbn.08-162}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
201799
201877
20191212
20201010
202188
20223030
202388
20242020
20251717
20261010

Its field-weighted citation impact is 2.59: it has been cited 2.59 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Health Sciences › Medicine › Biochemistry (medical) › Antioxidant Activity and Oxidative Stress

  • total antioxidant capacity
  • human plasma
  • 96-well microplate assay
  • ABTS radical scavenging
  • myoglobin oxidation
  • hydrogen peroxide
  • Trolox equivalent
  • sex differences

Work with this paper

Most-cited papers in Medicine

All highly cited Medicine papers

Questions about this paper

How do I cite this paper in APA style?

Kambayashi, Y., Bình, N. T., Asakura, H., Hibino, Y., Hitomi, Y., Nakamura, H., & Ogino, K. (2009). Efficient Assay for Total Antioxidant Capacity in Human Plasma Using a 96-Well Microplate. Journal of Clinical Biochemistry and Nutrition, 44(1), 46–51. https://doi.org/10.3164/jcbn.08-162

How many times has this paper been cited?

182 times, according to OpenAlex on 27 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Journal of Clinical Biochemistry and Nutrition: sign in and open the PDF from this page.

Who wrote this paper?

Yasuhiro Kambayashi, Nguyễn Thanh Bình, Hiroki Asakura, Yuri Hibino, Yoshiaki Hitomi, Hiroyuki Nakamura, Keiki Ogino.

What is the DOI of this paper?

10.3164/jcbn.08-162, permanently at https://doi.org/10.3164/jcbn.08-162. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 27 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.