Journal article · 2025 · Open access

Dual‐Chamber One‐Step Molding Actuator with Straight‐Curved Crease Prismatic Design for Large‐Range Motions and Structural Stability

Qinlin Tan, Yanlin Chen, Meng Zhou, Shuk Fan Tong, Sicong Liu, Raymond Kai‐Yu Tong

Advanced Science, 13(2), e14441 · Published 20 November 2025 · DOI 10.1002/advs.202514441

Open full textCite this paper

In brief

“Dual‐Chamber One‐Step Molding Actuator with Straight‐Curved Crease Prismatic Design for Large‐Range Motions and Structural Stability” is a 2025 journal article by Qinlin Tan and 5 co-authors, published in Advanced Science. OpenAlex counts 7 citations as of 22 November 2026, which puts it in the top 2% of works published in 2025 by citations. It is open access under a CC BY licence: the full text is free to read at Advanced Science.

Citations
7
Most cited in
2026 (7)
Field-weighted impact
1.23
References
60
Authors
6

Abstract

Soft actuators are gaining attention for their exceptional deformability and adaptability to meet the diverse demands of practical soft robotics applications. However, soft actuators with pneumatic actuation often struggle to simultaneously achieve large-range motions and structural stability. Addressing this challenge, a dual-chamber straight-curved crease origami prismatic (SCOP) actuator is proposed that introduces anisotropic stiffness through origami-inspired straight-curved creases and a foldable partition, enabling multidimensional motions including elongation and contraction, with an axial displacement reaching 106.7% of the actuator's original length (elongation 51.1% and contraction 55.6%), over 160° bidirectional bending, and a 209% increase in structural stability compared to curve crease bellows. The actuator is fabricated through one-step molding using a single material, and its principles, modeling, and design are systematically analyzed. The versatility and feasibility of the SCOP actuator are validated through its integrations into a wearable assistive device, a soft gripper, and a single-actuator crawling robot, which leverage various combinations of the SCOP's actuation modes to meet diverse motion requirements. This design provides a high-performance and practical solution for soft robotic systems requiring large-range, multidirectional motions with enhanced strength and reliability.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Tan, Q., Chen, Y., Zhou, M., Tong, S. F., Liu, S., & Tong, R. K. (2025). Dual‐Chamber One‐Step Molding Actuator with Straight‐Curved Crease Prismatic Design for Large‐Range Motions and Structural Stability. Advanced Science, 13(2), e14441. https://doi.org/10.1002/advs.202514441

MLA 9

Tan, Qinlin, et al. “Dual‐Chamber One‐Step Molding Actuator with Straight‐Curved Crease Prismatic Design for Large‐Range Motions and Structural Stability.” Advanced Science, vol. 13, no. 2, 2025, p. e14441. https://doi.org/10.1002/advs.202514441.

Chicago

Tan, Qinlin, Yanlin Chen, Meng Zhou, Shuk Fan Tong, Sicong Liu, and Raymond Kai‐Yu Tong. 2025. “Dual‐Chamber One‐Step Molding Actuator with Straight‐Curved Crease Prismatic Design for Large‐Range Motions and Structural Stability.” Advanced Science 13 (2): e14441. https://doi.org/10.1002/advs.202514441.

Harvard

Tan, Q. et al. (2025) ‘Dual‐Chamber One‐Step Molding Actuator with Straight‐Curved Crease Prismatic Design for Large‐Range Motions and Structural Stability’, Advanced Science, 13(2), p. e14441. doi:10.1002/advs.202514441.

IEEE

Q. Tan, Y. Chen, M. Zhou, S. F. Tong, S. Liu, and R. K. Tong, “Dual‐Chamber One‐Step Molding Actuator with Straight‐Curved Crease Prismatic Design for Large‐Range Motions and Structural Stability,” Advanced Science, vol. 13, no. 2, p. e14441, 2025, doi: 10.1002/advs.202514441.

BibTeX

@article{tan2025dual,
  title     = {{Dual‐Chamber One‐Step Molding Actuator with Straight‐Curved Crease Prismatic Design for Large‐Range Motions and Structural Stability}},
  author    = {Tan, Qinlin and Chen, Yanlin and Zhou, Meng and Tong, Shuk Fan and Liu, Sicong and Tong, Raymond Kai‐Yu},
  journal   = {Advanced Science},
  year      = {2025},
  volume    = {13},
  number    = {2},
  pages     = {e14441},
  doi       = {10.1002/advs.202514441},
  url       = {https://doi.org/10.1002/advs.202514441}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications

  • soft actuators
  • pneumatic actuation
  • origami-inspired design
  • prismatic actuators
  • anisotropic stiffness
  • structural stability
  • soft robotics
  • wearable assistive device

Work with this paper

Most-cited papers in Engineering

All highly cited Engineering papers

Questions about this paper

How do I cite this paper in APA style?

Tan, Q., Chen, Y., Zhou, M., Tong, S. F., Liu, S., & Tong, R. K. (2025). Dual‐Chamber One‐Step Molding Actuator with Straight‐Curved Crease Prismatic Design for Large‐Range Motions and Structural Stability. Advanced Science, 13(2), e14441. https://doi.org/10.1002/advs.202514441

How many times has this paper been cited?

7 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Advanced Science: sign in and open the full text from this page.

Who wrote this paper?

Qinlin Tan, Yanlin Chen, Meng Zhou, Shuk Fan Tong, Sicong Liu, Raymond Kai‐Yu Tong.

What is the DOI of this paper?

10.1002/advs.202514441, permanently at https://doi.org/10.1002/advs.202514441. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.