Journal article · 2000

Double-Wall, Transtibial Prosthetic Socket Fabricated Using Selective Laser Sintering: A Case Study

Bill Rogers A, Sean Stephens, Andrew J. Gitter, Gordon W. Bosker, Richard Crawford

JPO Journal of Prosthetics and Orthotics, 12(3), 97–103 · Published 1 November 2000 · DOI 10.1097/00008526-200012030-00007

View at the publisherCite this paper

In brief

“Double-Wall, Transtibial Prosthetic Socket Fabricated Using Selective Laser Sintering: A Case Study” is a 2000 journal article by Bill Rogers A and 4 co-authors, published in JPO Journal of Prosthetics and Orthotics. OpenAlex counts 47 citations as of 22 November 2026. The publisher's version is not open access, and OpenAlex records no free legal copy.

Citations
47
Most cited in
2023 (5)
Field-weighted impact
0.76
Authors
5

Abstract

The primary goal of this study was to test the feasibility of using selective laser sintering (SLS) to fabricate a functional transtibial prosthetic socket. Prosthetic socket computer-assisted design and computer-assisted manufacturing techniques were combined with SLS technology to produce a sophisticated, monolithic, transtibial prosthetic socket. The socket combined a rigid outer shell with a variably… Read the full abstract at the publisher.

Excerpt. This paper is not open access.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

A, B. R., Stephens, S., Gitter, A. J., Bosker, G. W., & Crawford, R. (2000). Double-Wall, Transtibial Prosthetic Socket Fabricated Using Selective Laser Sintering: A Case Study. JPO Journal of Prosthetics and Orthotics, 12(3), 97–103. https://doi.org/10.1097/00008526-200012030-00007

MLA 9

A, Bill Rogers, et al. “Double-Wall, Transtibial Prosthetic Socket Fabricated Using Selective Laser Sintering: A Case Study.” JPO Journal of Prosthetics and Orthotics, vol. 12, no. 3, 2000, pp. 97–103. https://doi.org/10.1097/00008526-200012030-00007.

Chicago

A, Bill Rogers, Sean Stephens, Andrew J. Gitter, Gordon W. Bosker, and Richard Crawford. 2000. “Double-Wall, Transtibial Prosthetic Socket Fabricated Using Selective Laser Sintering: A Case Study.” JPO Journal of Prosthetics and Orthotics 12 (3): 97–103. https://doi.org/10.1097/00008526-200012030-00007.

Harvard

A, B. R. et al. (2000) ‘Double-Wall, Transtibial Prosthetic Socket Fabricated Using Selective Laser Sintering: A Case Study’, JPO Journal of Prosthetics and Orthotics, 12(3), pp. 97–103. doi:10.1097/00008526-200012030-00007.

IEEE

B. R. A, S. Stephens, A. J. Gitter, G. W. Bosker, and R. Crawford, “Double-Wall, Transtibial Prosthetic Socket Fabricated Using Selective Laser Sintering: A Case Study,” JPO Journal of Prosthetics and Orthotics, vol. 12, no. 3, pp. 97–103, 2000, doi: 10.1097/00008526-200012030-00007.

BibTeX

@article{a2000double,
  title     = {{Double-Wall, Transtibial Prosthetic Socket Fabricated Using Selective Laser Sintering: A Case Study}},
  author    = {A, Bill Rogers and Stephens, Sean and Gitter, Andrew J. and Bosker, Gordon W. and Crawford, Richard},
  journal   = {JPO Journal of Prosthetics and Orthotics},
  year      = {2000},
  volume    = {12},
  number    = {3},
  pages     = {97--103},
  doi       = {10.1097/00008526-200012030-00007},
  url       = {https://doi.org/10.1097/00008526-200012030-00007}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
201622
201722
201811
201922
202033
202122
202233
202355
202422
202633

Its field-weighted citation impact is 0.76: it has been cited 0.76 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics

  • selective laser sintering
  • computer-aided design
  • socket comfort
  • transtibial amputees

Work with this paper

Most-cited papers in Engineering

All highly cited Engineering papers

Questions about this paper

How do I cite this paper in APA style?

A, B. R., Stephens, S., Gitter, A. J., Bosker, G. W., & Crawford, R. (2000). Double-Wall, Transtibial Prosthetic Socket Fabricated Using Selective Laser Sintering: A Case Study. JPO Journal of Prosthetics and Orthotics, 12(3), 97–103. https://doi.org/10.1097/00008526-200012030-00007

How many times has this paper been cited?

47 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

OpenAlex records no free legal copy. Check your library's access, the authors' pages or a repository, or ask the corresponding author for a copy.

Who wrote this paper?

Bill Rogers A, Sean Stephens, Andrew J. Gitter, Gordon W. Bosker, Richard Crawford.

What is the DOI of this paper?

10.1097/00008526-200012030-00007, permanently at https://doi.org/10.1097/00008526-200012030-00007. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.