Paper · 2016 · Open access

Displacement Analysis and Output Force Estimation of A Compliant Robotic Microgripper

Chintireddy Sharath Reddy, J. Jagadesh Kumar

Zenodo (CERN European Organization for Nuclear Research), 2(5), 91–96 · Published 30 October 2016 · DOI 10.5281/zenodo.21599308

Open full textCite this paper

In brief

“Displacement Analysis and Output Force Estimation of A Compliant Robotic Microgripper” is a 2016 paper by Chintireddy Sharath Reddy and J. Jagadesh Kumar, published in Zenodo (CERN European Organization for Nuclear Research). OpenAlex counts 0 citations as of 22 November 2026. It is open access under a CC BY licence: the full text is free to read at Zenodo (CERN European Organization for Nuclear Research).

Citations
0
References
1
Authors
2

Abstract

Micromanipulators should be able to accurately control gripping force in order to avoid any damage to the small size delicate objects, which are less than 1mm size. Hence gripping force determination according to application and subsequently control of gripping is an essential parameter in micromanipulators. The present work deals with the study of a Four-piezo actuated compliant micro gripper, kinematical modelling of the micro gripper and estimation of output force using Pseudo-rigid body model (PRBM) of the gripper. The study involves computation of tip displacement of the micro-gripper using the available mathematical equations and formulae and thereafter comparing the results with Finite Element Method values of the 3D model of the gripper using ABAQUS. The current research also involves calculation of the gripping force using equations of motion of one finger of the gripper using SIMMECHANICS. Finally the feedback control mechanism is developed using SIMULINK to control the gripping force.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Reddy, C. S., & Kumar, J. J. (2016). Displacement Analysis and Output Force Estimation of A Compliant Robotic Microgripper. Zenodo (CERN European Organization for Nuclear Research), 2(5), 91–96. https://doi.org/10.5281/zenodo.21599308

MLA 9

Reddy, Chintireddy Sharath, and J. Jagadesh Kumar. “Displacement Analysis and Output Force Estimation of A Compliant Robotic Microgripper.” Zenodo (CERN European Organization for Nuclear Research), vol. 2, no. 5, 2016, pp. 91–96. https://doi.org/10.5281/zenodo.21599308.

Chicago

Reddy, Chintireddy Sharath and J. Jagadesh Kumar. 2016. “Displacement Analysis and Output Force Estimation of A Compliant Robotic Microgripper.” Zenodo (CERN European Organization for Nuclear Research) 2 (5): 91–96. https://doi.org/10.5281/zenodo.21599308.

Harvard

Reddy, C. S. and Kumar, J. J. (2016) ‘Displacement Analysis and Output Force Estimation of A Compliant Robotic Microgripper’, Zenodo (CERN European Organization for Nuclear Research), 2(5), pp. 91–96. doi:10.5281/zenodo.21599308.

IEEE

C. S. Reddy and J. J. Kumar, “Displacement Analysis and Output Force Estimation of A Compliant Robotic Microgripper,” Zenodo (CERN European Organization for Nuclear Research), vol. 2, no. 5, pp. 91–96, 2016, doi: 10.5281/zenodo.21599308.

BibTeX

@article{reddy2016displacement,
  title     = {{Displacement Analysis and Output Force Estimation of A Compliant Robotic Microgripper}},
  author    = {Reddy, Chintireddy Sharath and Kumar, J. Jagadesh},
  journal   = {Zenodo (CERN European Organization for Nuclear Research)},
  year      = {2016},
  volume    = {2},
  number    = {5},
  pages     = {91--96},
  doi       = {10.5281/zenodo.21599308},
  url       = {https://doi.org/10.5281/zenodo.21599308}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Physical Sciences › Engineering › Control and Systems Engineering › Piezoelectric Actuators and Control

  • piezoelectric actuation
  • micromanipulation
  • tip displacement
  • pseudo-rigid-body model
  • kinematic modelling
  • finite element analysis
  • equations of motion
  • feedback control

Work with this paper

Most-cited papers in Engineering

All highly cited Engineering papers

Questions about this paper

How do I cite this paper in APA style?

Reddy, C. S., & Kumar, J. J. (2016). Displacement Analysis and Output Force Estimation of A Compliant Robotic Microgripper. Zenodo (CERN European Organization for Nuclear Research), 2(5), 91–96. https://doi.org/10.5281/zenodo.21599308

How many times has this paper been cited?

0 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Zenodo (CERN European Organization for Nuclear Research): sign in and open the full text from this page.

Who wrote this paper?

Chintireddy Sharath Reddy, J. Jagadesh Kumar.

What is the DOI of this paper?

10.5281/zenodo.21599308, permanently at https://doi.org/10.5281/zenodo.21599308. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.