Journal article · 2024 · Open access

Discomfort/pain due to peri‐implant probing at titanium and zirconium implants: A cross‐sectional study

Florian Bussmeyer, Michael Saminsky, Peter Eickholz

Clinical Oral Implants Research, 35(9), 1081–1090 · Published 27 May 2024 · DOI 10.1111/clr.14298

Open PDFView at the publisherCite this paper

In brief

“Discomfort/pain due to peri‐implant probing at titanium and zirconium implants: A cross‐sectional study” is a 2024 journal article by Florian Bussmeyer and 2 co-authors, published in Clinical Oral Implants Research. OpenAlex counts 8 citations as of 18 November 2026. It is open access under a CC BY-NC licence: the full text is free to read at Clinical Oral Implants Research.

Citations
8
Most cited in
2026 (5)
Field-weighted impact
2.31
References
47
Authors
3

Abstract

OBJECTIVE: This study was designed to compare discomfort/pain after periodontal and peri-implant probing in patients with titanium compared with zirconium implants. METHODS: One examiner recruited and examined 70 patients, each of whom had a dental implant with a contralateral tooth; 37 patients had titanium implants of various types and 33 patients had zirconium implants; one implant was analyzed for each patient. Periodontal and peri-implant probing pocket depth (PPD) and clinical attachment level (CAL) were assessed. Immediately after probing, patients rated their discomfort/pain with a visual analog scale (VAS). The emergence profiles of implant crowns were assessed on periapical radiographs of the implants. RESULTS: Seventy patients with a median age of 55 years (interquartile range [IQR]: 42-65 years), including 43 females and 16 current smokers, were examined. The mean PPD and bleeding on probing (BOP) were higher around implants than around teeth (p < .001). CAL and suppuration were well-balanced between implants and teeth. Peri-implant probing caused significantly more discomfort/pain than periodontal probing [median VAS score: 12.5 (IQR 4-22) vs. 9 (2-15); p < .001]. Logistic regression revealed that discomfort/pain after peri-implant probing was less intense in patients who had taken analgesic medication (p = .021) and around titanium implants (p = .037). CONCLUSIONS: Peri-implant probing caused significantly more discomfort/pain than periodontal probing. Patients who had taken analgesic medication experienced less discomfort and pain with peri-implant probing than those who had not; furthermore, titanium implants were associated with less pain than zirconium implants.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Bussmeyer, F., Saminsky, M., & Eickholz, P. (2024). Discomfort/pain due to peri‐implant probing at titanium and zirconium implants: A cross‐sectional study. Clinical Oral Implants Research, 35(9), 1081–1090. https://doi.org/10.1111/clr.14298

MLA 9

Bussmeyer, Florian, et al. “Discomfort/pain due to peri‐implant probing at titanium and zirconium implants: A cross‐sectional study.” Clinical Oral Implants Research, vol. 35, no. 9, 2024, pp. 1081–1090. https://doi.org/10.1111/clr.14298.

Chicago

Bussmeyer, Florian, Michael Saminsky, and Peter Eickholz. 2024. “Discomfort/pain due to peri‐implant probing at titanium and zirconium implants: A cross‐sectional study.” Clinical Oral Implants Research 35 (9): 1081–1090. https://doi.org/10.1111/clr.14298.

Harvard

Bussmeyer, F., Saminsky, M. and Eickholz, P. (2024) ‘Discomfort/pain due to peri‐implant probing at titanium and zirconium implants: A cross‐sectional study’, Clinical Oral Implants Research, 35(9), pp. 1081–1090. doi:10.1111/clr.14298.

IEEE

F. Bussmeyer, M. Saminsky, and P. Eickholz, “Discomfort/pain due to peri‐implant probing at titanium and zirconium implants: A cross‐sectional study,” Clinical Oral Implants Research, vol. 35, no. 9, pp. 1081–1090, 2024, doi: 10.1111/clr.14298.

BibTeX

@article{bussmeyer2024discomfort,
  title     = {{Discomfort/pain due to peri‐implant probing at titanium and zirconium implants: A cross‐sectional study}},
  author    = {Bussmeyer, Florian and Saminsky, Michael and Eickholz, Peter},
  journal   = {Clinical Oral Implants Research},
  year      = {2024},
  volume    = {35},
  number    = {9},
  pages     = {1081--1090},
  doi       = {10.1111/clr.14298},
  url       = {https://doi.org/10.1111/clr.14298}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
202411
202522
202655

Its field-weighted citation impact is 2.31: it has been cited 2.31 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Health Sciences › Dentistry › Oral Surgery › Dental Implant Techniques and Outcomes

  • periodontal probing
  • titanium implants
  • zirconium implants
  • implant material comparison
  • probing depth
  • clinical attachment level
  • bleeding on probing
  • analgesic use

Work with this paper

Most-cited papers in Dentistry

All highly cited Dentistry papers

Questions about this paper

How do I cite this paper in APA style?

Bussmeyer, F., Saminsky, M., & Eickholz, P. (2024). Discomfort/pain due to peri‐implant probing at titanium and zirconium implants: A cross‐sectional study. Clinical Oral Implants Research, 35(9), 1081–1090. https://doi.org/10.1111/clr.14298

How many times has this paper been cited?

8 times, according to OpenAlex on 18 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Clinical Oral Implants Research: sign in and open the PDF from this page.

Who wrote this paper?

Florian Bussmeyer, Michael Saminsky, Peter Eickholz.

What is the DOI of this paper?

10.1111/clr.14298, permanently at https://doi.org/10.1111/clr.14298. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 18 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.