Journal article · 2026 · Open access
Digital implant transfer with coded healing abutments: A site-by-scanner accuracy study
Journal of Dentistry, 177, 107137 · Published 27 October 2026 · DOI 10.1016/j.jdent.2026.107137
In brief
“Digital implant transfer with coded healing abutments: A site-by-scanner accuracy study” is a 2026 journal article by Ioannis Papathanasiou and 5 co-authors, published in Journal of Dentistry. OpenAlex counts 0 citations as of 18 November 2026. It is open access under a CC BY licence: the full text is free to read at Journal of Dentistry.
- Citations
- 0
- References
- 37
- Authors
- 6
Abstract
OBJECTIVES: To compare the pose-transfer accuracy of single-implant digital impressions obtained with three intraoral scanners across three predefined site-specific coded healing-abutment configurations. METHODS: A partially edentulous maxillary model containing molar, incisor, and premolar implant sites was equipped with 2-mm coded healing abutments (iPhysio, LYRA ETK). A metrological reference was generated with an industrial structured-light scanner. Twenty independently initiated acquisition sessions were performed with each of three IOSs on the same master model: Medit i900, 3Shape TRIOS 6, and Dentsply Sirona Primescan 2. Coded components were replaced with their corresponding CAD-library geometries, generating 60 datasets and 180 site-level observations. Metrological evaluation included translational magnitude, angular deviation, signed mean surface distance, and within-surface distance dispersion. Generalized estimating equations with robust covariance were used to test IOS, site-specific CHA condition, and IOS × condition effects (α=0.05). RESULTS: The site-specific CHA condition significantly affected translational magnitude (Wald χ²(2)=183.88, p < 0.001) and angular deviation (Wald χ²(2)=56.12, p < 0.001). Significant IOS × condition interactions were identified for translational magnitude (Wald χ²(4)=120.12, p < 0.001), angular deviation (Wald χ²(4)=80.15, p < 0.001), signed mean surface distance (Wald χ²(4)=35.87, p < 0.001), and within-surface dispersion (Wald χ²(4)=46.55, p < 0.001). The marginal IOS effect was not significant for translational magnitude (p = 0.427) or angular deviation (p = 0.112). Condition-specific comparisons showed different performance patterns among scanners, with no IOS demonstrating uniformly lower pose-transfer deviation across all tested conditions. CONCLUSIONS: Within this in vitro model, coded healing-abutment transfer accuracy differed among the tested site-specific CHA configurations and showed significant IOS × experimental-condition interactions. Because anatomical location and CHA geometry were not independently varied, these effects cannot be attributed exclusively to implant site. CLINICAL SIGNIFICANCE: Performance differed across specific scanner-site-component combinations; clinicians should therefore avoid assuming uniform scanner performance across coded healing-abutment configurations until these in vitro findings are clinically validated.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Papathanasiou, I., Ruggiero, G., Kamposiora, P., Zarone, F., Papavasiliou, G., & Sorrentino, R. (2026). Digital implant transfer with coded healing abutments: A site-by-scanner accuracy study. Journal of Dentistry, 177, 107137. https://doi.org/10.1016/j.jdent.2026.107137
MLA 9
Papathanasiou, Ioannis, et al. “Digital implant transfer with coded healing abutments: A site-by-scanner accuracy study.” Journal of Dentistry, vol. 177, 2026, p. 107137. https://doi.org/10.1016/j.jdent.2026.107137.
Chicago
Papathanasiou, Ioannis, Gennaro Ruggiero, Phophi Kamposiora, Fernando Zarone, George Papavasiliou, and Roberto Sorrentino. 2026. “Digital implant transfer with coded healing abutments: A site-by-scanner accuracy study.” Journal of Dentistry 177: 107137. https://doi.org/10.1016/j.jdent.2026.107137.
Harvard
Papathanasiou, I. et al. (2026) ‘Digital implant transfer with coded healing abutments: A site-by-scanner accuracy study’, Journal of Dentistry, 177, p. 107137. doi:10.1016/j.jdent.2026.107137.
IEEE
I. Papathanasiou, G. Ruggiero, P. Kamposiora, F. Zarone, G. Papavasiliou, and R. Sorrentino, “Digital implant transfer with coded healing abutments: A site-by-scanner accuracy study,” Journal of Dentistry, vol. 177, p. 107137, 2026, doi: 10.1016/j.jdent.2026.107137.
BibTeX
@article{papathanasiou2026digital,
title = {{Digital implant transfer with coded healing abutments: A site-by-scanner accuracy study}},
author = {Papathanasiou, Ioannis and Ruggiero, Gennaro and Kamposiora, Phophi and Zarone, Fernando and Papavasiliou, George and Sorrentino, Roberto},
journal = {Journal of Dentistry},
year = {2026},
volume = {177},
pages = {107137},
doi = {10.1016/j.jdent.2026.107137},
url = {https://doi.org/10.1016/j.jdent.2026.107137}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Topic and keywords
Health Sciences › Dentistry › Oral Surgery › Dental Implant Techniques and Outcomes
- digital implant impressions
- intraoral scanners
- structured light scanner
- surface distance
- scanner comparison
- in vitro model
Work with this paper
Most-cited papers in Dentistry
- Periodontal Disease in Pregnancy II. Correlation Between Oral Hygiene and Periodontal ConditionJohn Silness, Harald A. Löe · Acta Odontologica Scandinavica · 1964 · 8,071 citations
- Periodontal Disease in Pregnancy I. Prevalence and SeverityHarald A. Löe, John Silness · Acta Odontologica Scandinavica · 1963 · 7,339 citations
- Microbial complexes in subgingival plaqueS. S. Socransky, Anne D. Haffajee, MaryAnn Cugini and 2 more · Journal Of Clinical Periodontology · 1998 · 5,207 citations
- Development of a Classification System for Periodontal Diseases and ConditionsGary C. Armitage · Annals of Periodontology · 1999 · 5,198 citations
- Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for Clinical and Research Applications: Recommendations of the International RDC/TMD Consortium Network* and Orofacial Pain Special Interest Group†ERIC L. SCHIFFMAN, Richard K. Ohrbach, Edmond L. Truelove and 27 more · Journal of Oral & Facial Pain and Headache · 2014 · 4,942 citations
Questions about this paper
How do I cite this paper in APA style?
Papathanasiou, I., Ruggiero, G., Kamposiora, P., Zarone, F., Papavasiliou, G., & Sorrentino, R. (2026). Digital implant transfer with coded healing abutments: A site-by-scanner accuracy study. Journal of Dentistry, 177, 107137. https://doi.org/10.1016/j.jdent.2026.107137
How many times has this paper been cited?
0 times, according to OpenAlex on 18 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at Journal of Dentistry: sign in and open the PDF from this page.
Who wrote this paper?
Ioannis Papathanasiou, Gennaro Ruggiero, Phophi Kamposiora, Fernando Zarone, George Papavasiliou, Roberto Sorrentino.
What is the DOI of this paper?
10.1016/j.jdent.2026.107137, permanently at https://doi.org/10.1016/j.jdent.2026.107137. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 18 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.