Dissertation · 2009 · Open access

Dexterity enhancement in microsurgery using a microgripper and motion-scaling system

S. Ku

cIRcle (University of British Columbia) · Published 1 January 2009 · DOI 10.14288/1.0065149

Open full textView at the publisherCite this paper

In brief

“Dexterity enhancement in microsurgery using a microgripper and motion-scaling system” is a 2009 dissertation by S. Ku, published in cIRcle (University of British Columbia). OpenAlex counts 1 citations as of 22 November 2026. It is open access: the full text is free to read at cIRcle (University of British Columbia).

Citations
1
References
28
Authors
1

Abstract

The design and control of a six-degree-of-freedom (6-DOF) force-reflecting motion-scaling teleoperation system was presented in [1]. In this thesis, a remotely controlled microgripper is developed as an end-effector for this system. The device features small size and weight, and large stroke and force compared to other designs. A stylus-shaped teleoperation master that measures the force at the fingers of the operator provides an intuitive means for operating the microgripper. This design also enables the microgripper to be used as a hand-held instrument. Force sensing enables the accurate measurement and control of tool-tissue forces, as well as the emulation of different mechanical devices. Issues concerning the design, control, and application to microsurgical tasks are addressed here. 6-DOF force/torque sensing has also been added to the teleoperation system, enabling the use of hand and environment forces to improve teleoperation transparency, and enabling the measurement of forces during microsurgery. Several methods for teleoperation control have been implemented, and their potential use in microsurgery is discussed. In addition, experiments have been conducted to quantify the effects of scaled motion and scaled force feedback on teleoperation performance in tasks involving sub-millimetre motions and contact forces from 3 to 15 grams. Significant improvements in accuracy of task execution as well as operator confidence and fatigue were observed when scaled motion and scaled force feedback were provided.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Ku, S. (2009). Dexterity enhancement in microsurgery using a microgripper and motion-scaling system. cIRcle (University of British Columbia). https://doi.org/10.14288/1.0065149

MLA 9

Ku, S. “Dexterity enhancement in microsurgery using a microgripper and motion-scaling system.” cIRcle (University of British Columbia), 2009. https://doi.org/10.14288/1.0065149.

Chicago

Ku, S. 2009. “Dexterity enhancement in microsurgery using a microgripper and motion-scaling system.” cIRcle (University of British Columbia). https://doi.org/10.14288/1.0065149.

Harvard

Ku, S. (2009) ‘Dexterity enhancement in microsurgery using a microgripper and motion-scaling system’, cIRcle (University of British Columbia). doi:10.14288/1.0065149.

IEEE

S. Ku, “Dexterity enhancement in microsurgery using a microgripper and motion-scaling system,” cIRcle (University of British Columbia), 2009, doi: 10.14288/1.0065149.

BibTeX

@phdthesis{ku2009dexterity,
  title     = {{Dexterity enhancement in microsurgery using a microgripper and motion-scaling system}},
  author    = {Ku, S.},
  year      = {2009},
  doi       = {10.14288/1.0065149},
  url       = {https://doi.org/10.14288/1.0065149}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems

  • microsurgery
  • microgripper
  • force feedback
  • force/torque sensing
  • teleoperation transparency
  • operator fatigue
  • teleoperation control

Work with this paper

Most-cited papers in Engineering

All highly cited Engineering papers

Questions about this paper

How do I cite this paper in APA style?

Ku, S. (2009). Dexterity enhancement in microsurgery using a microgripper and motion-scaling system. cIRcle (University of British Columbia). https://doi.org/10.14288/1.0065149

How many times has this paper been cited?

1 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at cIRcle (University of British Columbia): sign in and open the full text from this page.

Who wrote this paper?

S. Ku.

What is the DOI of this paper?

10.14288/1.0065149, permanently at https://doi.org/10.14288/1.0065149. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.