Development of Wavelength-Dispersive X-ray Spectrometer for a Conventional Analytical Transmission Electron Microscope

T Masami, Katsuya Masao, F Kurio, K Jun

Microscopy and Microanalysis, 12(S02), 866–867 · Published 31 July 2006 · DOI 10.1017/s1431927606067444

Free PDFView at the publisherCite this paper

In brief

“Development of Wavelength-Dispersive X-ray Spectrometer for a Conventional Analytical Transmission Electron Microscope” is a 2006 journal article by T Masami and 3 co-authors, published in Microscopy and Microanalysis. OpenAlex counts 1 citations as of 16 November 2026. It is open access: the full text is free to read at Microscopy and Microanalysis.

Citations
1
Field-weighted impact
0.24
Authors
4

Abstract

Characterization with nm-scale spatial resolution is important for developments of new functional materials.Recently, Terauchi et al. [1][2][3] constructed a compact wavelength-dispersive X-ray spectrometer, referred as the original spectrometer, for a transmission electron microscope (TEM) and succeeded to obtain a density of states (DOS) of the valence band with an energy resolution of better than 1 eV by using a TEM.It implies that the DOS of the valence band (by X-ray emission spectroscopy: XES) and the conduction band (by electron energy-loss spectroscopy: EELS) can be obtainable from a specified small specimen area based on a transmission electron microscopy [4].Furthermore, the spectrometer dose not disturb the spatial resolution of a TEM, because it does not have a moving mechanism as in a case of WDS spectrometers of EPMA.We have started a project to renew the WDS spectrometer to attach to a conventional analytical TEM.Basic concept of the first spectrometer (high energy-dispersion version) is the same as that of the original one.It composed of 1) three varied-line-spacing (VLS) gratings, 2) a back-illumination type CCD detector and 3) X-ray collection mirrors.The measurable energy range is from 60 to 1200 eV.Compared to the original spectrometer, energy dispersion in an energy range of 60-400eV was improved by about two times.This first spectrometer is different from the original one in the take off angle of X-ray to measure.The original one was designed to measure X-rays emitted in almost horizontal direction.As a result, a specimen always has to be tilted more than 20 deg.for measurements.It is not convenient for a conventional analytical TEM.Thus, this new instrument is designed to measure the X-ray in the direction with an angle of elevation of about 35 deg.A specimen tilt for XES measurements is no more needed.The spectrometer is firstly installed in a TEM of JEM2010 as shown in FIG. 1.A silicon L-emission (valence bands→L 2,3 -shell) spectrum obtained by the first spectrometer is shown in FIG. 2. The spectrum represents the DOS of the valence bands with s-symmetry showing peak structures labeled by symmetry characters of L2', L1, X4 and L3'.The second WDS spectrometer is designed to cover an energy range of 60-1200 eV by using newly designed two VLS gratings.The energy dispersion of the spectrometer is designed smaller than that of the first spectrometer to obtain a larger collection angle, because of an extremely small emission efficiency of the soft-X-ray region to measure.Figure 3 shows a

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Masami, T., Masao, K., Kurio, F., & Jun, K. (2006). Development of Wavelength-Dispersive X-ray Spectrometer for a Conventional Analytical Transmission Electron Microscope. Microscopy and Microanalysis, 12(S02), 866–867. https://doi.org/10.1017/s1431927606067444

MLA 9

Masami, T, et al. “Development of Wavelength-Dispersive X-ray Spectrometer for a Conventional Analytical Transmission Electron Microscope.” Microscopy and Microanalysis, vol. 12, no. S02, 2006, pp. 866–867. https://doi.org/10.1017/s1431927606067444.

Chicago

Masami, T, Katsuya Masao, F Kurio, and K Jun. 2006. “Development of Wavelength-Dispersive X-ray Spectrometer for a Conventional Analytical Transmission Electron Microscope.” Microscopy and Microanalysis 12 (S02): 866–867. https://doi.org/10.1017/s1431927606067444.

Harvard

Masami, T. et al. (2006) ‘Development of Wavelength-Dispersive X-ray Spectrometer for a Conventional Analytical Transmission Electron Microscope’, Microscopy and Microanalysis, 12(S02), pp. 866–867. doi:10.1017/s1431927606067444.

IEEE

T. Masami, K. Masao, F. Kurio, and K. Jun, “Development of Wavelength-Dispersive X-ray Spectrometer for a Conventional Analytical Transmission Electron Microscope,” Microscopy and Microanalysis, vol. 12, no. S02, pp. 866–867, 2006, doi: 10.1017/s1431927606067444.

BibTeX

@article{masami2006development,
  title     = {{Development of Wavelength-Dispersive X-ray Spectrometer for a Conventional Analytical Transmission Electron Microscope}},
  author    = {Masami, T and Masao, Katsuya and Kurio, F and Jun, K},
  journal   = {Microscopy and Microanalysis},
  year      = {2006},
  volume    = {12},
  number    = {S02},
  pages     = {866--867},
  doi       = {10.1017/s1431927606067444},
  url       = {https://doi.org/10.1017/s1431927606067444}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Physical Sciences › Materials Science › Surfaces, Coatings and Films › Electron and X-Ray Spectroscopy Techniques

  • X-ray emission spectroscopy
  • electron energy loss spectroscopy
  • varied-line-spacing grating
  • valence band density of states
  • energy dispersion
  • compact spectrometer design

Work with this paper

Most-cited papers in Materials Science

All highly cited Materials Science papers

Questions about this paper

How do I cite this paper in APA style?

Masami, T., Masao, K., Kurio, F., & Jun, K. (2006). Development of Wavelength-Dispersive X-ray Spectrometer for a Conventional Analytical Transmission Electron Microscope. Microscopy and Microanalysis, 12(S02), 866–867. https://doi.org/10.1017/s1431927606067444

How many times has this paper been cited?

1 times, according to OpenAlex on 16 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access: read the free full text at Microscopy and Microanalysis.

Who wrote this paper?

T Masami, Katsuya Masao, F Kurio, K Jun.

What is the DOI of this paper?

10.1017/s1431927606067444. The permanent link is https://doi.org/10.1017/s1431927606067444.

Bibliographic data from OpenAlex (CC0), last checked 16 November 2026. ResearchGuru does not host this paper; the links go to the publisher or the repository that does.