Journal article · 2024 · Open access

Development of Rehabilitation Glove: Soft Robot Approach

Tomislav Bazina, Marko Kladarić, Ervin Kamenar, Goran Gregov

Actuators, 13(12), 472 · Published 22 November 2024 · DOI 10.3390/act13120472

Open PDFView at the publisherCite this paper

In brief

“Development of Rehabilitation Glove: Soft Robot Approach” is a 2024 journal article by Tomislav Bazina and 3 co-authors, published in Actuators. OpenAlex counts 18 citations as of 22 November 2026, which puts it in the top 3% of works published in 2024 by citations. It is open access under a CC BY licence: the full text is free to read at Actuators.

Citations
18
Most cited in
2026 (13)
Field-weighted impact
1.51
References
21
Authors
4

Abstract

This study describes the design, simulation, and development process of a rehabilitation glove driven by soft pneumatic actuators. A new, innovative finger soft actuator design has been developed through detailed kinematic and workspace analysis of anatomical fingers and their actuators. The actuator design combines cylindrical and ribbed geometries with a reinforcing element—a thicker, less extensible structure—resulting in an asymmetric cylindrical bellow actuator driven by positive pressure. The performance of the newly designed actuator for the rehabilitation glove was validated through numerical simulation in open-source software. The simulation results indicate actuators’ compatibility with human finger trajectories. Additionally, a rehabilitation glove was 3D-printed from soft materials, and the actuator’s flexibility and airtightness were analyzed across different wall thicknesses. The 0.8 mm wall thickness and thermoplastic polyurethane (TPU) material were chosen for the final design. Experiments confirmed a strong linear relationship between bending angle and pressure variations, as well as joint elongation and pressure changes. Next, pseudo-rigid kinematic models were developed for the index and little finger soft actuators, based solely on pressure and link lengths. The workspace of the soft actuator, derived through forward kinematics, was visually compared to that of the anatomical finger and experimentally recorded data. Finally, an ergonomic assessment of the complete rehabilitation glove in interaction with the human hand was conducted.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Bazina, T., Kladarić, M., Kamenar, E., & Gregov, G. (2024). Development of Rehabilitation Glove: Soft Robot Approach. Actuators, 13(12), 472. https://doi.org/10.3390/act13120472

MLA 9

Bazina, Tomislav, et al. “Development of Rehabilitation Glove: Soft Robot Approach.” Actuators, vol. 13, no. 12, 2024, p. 472. https://doi.org/10.3390/act13120472.

Chicago

Bazina, Tomislav, Marko Kladarić, Ervin Kamenar, and Goran Gregov. 2024. “Development of Rehabilitation Glove: Soft Robot Approach.” Actuators 13 (12): 472. https://doi.org/10.3390/act13120472.

Harvard

Bazina, T. et al. (2024) ‘Development of Rehabilitation Glove: Soft Robot Approach’, Actuators, 13(12), p. 472. doi:10.3390/act13120472.

IEEE

T. Bazina, M. Kladarić, E. Kamenar, and G. Gregov, “Development of Rehabilitation Glove: Soft Robot Approach,” Actuators, vol. 13, no. 12, p. 472, 2024, doi: 10.3390/act13120472.

BibTeX

@article{bazina2024development,
  title     = {{Development of Rehabilitation Glove: Soft Robot Approach}},
  author    = {Bazina, Tomislav and Kladarić, Marko and Kamenar, Ervin and Gregov, Goran},
  journal   = {Actuators},
  year      = {2024},
  volume    = {13},
  number    = {12},
  pages     = {472},
  doi       = {10.3390/act13120472},
  url       = {https://doi.org/10.3390/act13120472}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications

  • rehabilitation glove
  • soft pneumatic actuators
  • finger kinematics
  • forward kinematics
  • thermoplastic polyurethane
  • wall thickness
  • air tightness
  • ergonomic assessment

Work with this paper

Most-cited papers in Engineering

All highly cited Engineering papers

Questions about this paper

How do I cite this paper in APA style?

Bazina, T., Kladarić, M., Kamenar, E., & Gregov, G. (2024). Development of Rehabilitation Glove: Soft Robot Approach. Actuators, 13(12), 472. https://doi.org/10.3390/act13120472

How many times has this paper been cited?

18 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Actuators: sign in and open the PDF from this page.

Who wrote this paper?

Tomislav Bazina, Marko Kladarić, Ervin Kamenar, Goran Gregov.

What is the DOI of this paper?

10.3390/act13120472, permanently at https://doi.org/10.3390/act13120472. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.