Journal article · 2025 · Open access
Development of MEMS Based In-situ TEM Chips and Applications
Microscopy and Microanalysis, 31(Supplement_1) · Published 1 July 2025 · DOI 10.1093/mam/ozaf048.892
In brief
“Development of MEMS Based In-situ TEM Chips and Applications” is a 2025 journal article by Youhong Jiang and Hong‐Gang Liao, published in Microscopy and Microanalysis. OpenAlex counts 1 citations as of 16 November 2026, which puts it in the top 9% of works published in 2025 by citations. It is open access: the full text is free to read at Microscopy and Microanalysis.
- Citations
- 1
- Most cited in
- 2026 (1)
- Field-weighted impact
- 0.30
- References
- 5
- Authors
- 2
Abstract
Transmission electron microscopy (TEM) has emerged as a pivotal analytical tool in interdisciplinary research spanning chemical synthesis, energy materials development, and structural biology investigations [1,2]. High-resolution imaging and component analysis through TEM can visually present the morphology, structure and chemical composition of the material at atomic scale, which is important for material synthesis, bio-macromolecule analysis and the development of new functional materials. The evolution of TEM technology has facilitated a paradigm shift from static single-frame imaging to real-time dynamic observation. MEMS (Micro Electro Mechanical System) based in-situ chips with varieties of micro components on a single chip, enabled the observation of the dynamic of sample under stimulation of multi-fields (electric, thermal, force, fluid, etc.) in gas or liquid atmosphere [3-5]. We explored the fabrication processes of in-situ chips, and several kinds of high resolution liquid cell chips and high temperature heating chips were developed, including liquid phase flow cell, electrochemical liquid cell, high temperature heating chip (Figure.1). Chip-Nova Technology Co., Ltd helped with the development of high accuracy control system and the program, such as high high-precision temperature control system, which can reach the accuracy of 0.01°C. By bridging static characterization with real-time multimodal analysis, these tools illuminate fundamental mechanisms in chemical synthesis, energy material degradation, and biomolecular interactions, directly informing the design of advanced functional materials. An understanding of solid–liquid interfaces is of great importance for fundamental research as well as industrial applications. However, it has been very challenging to directly image solid–liquid interfaces with high resolution, thus their structure and properties are often unknown. With the above developed high resolution liquid cells, we studied a quasi-liquid phase between metal (In, Sn) nanoparticle surfaces and an aqueous solution observed using liquid cell transmission electron microscopy. Our real-time high-resolution imaging reveals a thin layer of liquid-like materials at the interfaces with the frequent appearance of small In nanoclusters. Such a quasi-liquid phase serves as an intermediate for the mass transport from the metal nanoparticle to the liquid. Density functional theory-molecular dynamics simulations demonstrate that the positive charges of In ions greatly contribute to the stabilization of the quasi-liquid phase on the metal surface. This study provides critical insights on solid–liquid interfaces, thus important to the synthesis and applications of metal nanoparticles related to interface reactions, such as catalysis and corrosion [6]. Display of In-situ TEM chips and platform (A) Schematic of in situ TEM flow holder and flow cell. (B) Gas heating chip and thermal field distribution. [5] (C) High-tilt TEM heating chip, in-situ high-tilt heating holder and high-precision temperature…
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Jiang, Y., & Liao, H. (2025). Development of MEMS Based In-situ TEM Chips and Applications. Microscopy and Microanalysis, 31(Supplement_1). https://doi.org/10.1093/mam/ozaf048.892
MLA 9
Jiang, Youhong, and Hong‐Gang Liao. “Development of MEMS Based In-situ TEM Chips and Applications.” Microscopy and Microanalysis, vol. 31, no. Supplement_1, 2025. https://doi.org/10.1093/mam/ozaf048.892.
Chicago
Jiang, Youhong and Hong‐Gang Liao. 2025. “Development of MEMS Based In-situ TEM Chips and Applications.” Microscopy and Microanalysis 31 (Supplement_1). https://doi.org/10.1093/mam/ozaf048.892.
Harvard
Jiang, Y. and Liao, H. (2025) ‘Development of MEMS Based In-situ TEM Chips and Applications’, Microscopy and Microanalysis, 31(Supplement_1). doi:10.1093/mam/ozaf048.892.
IEEE
Y. Jiang and H. Liao, “Development of MEMS Based In-situ TEM Chips and Applications,” Microscopy and Microanalysis, vol. 31, no. Supplement_1, 2025, doi: 10.1093/mam/ozaf048.892.
BibTeX
@article{jiang2025development,
title = {{Development of MEMS Based In-situ TEM Chips and Applications}},
author = {Jiang, Youhong and Liao, Hong‐Gang},
journal = {Microscopy and Microanalysis},
year = {2025},
volume = {31},
number = {Supplement_1},
doi = {10.1093/mam/ozaf048.892},
url = {https://doi.org/10.1093/mam/ozaf048.892}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Topic and keywords
Life Sciences › Biochemistry, Genetics and Molecular Biology › Structural Biology › Advanced Electron Microscopy Techniques and Applications
- liquid cell TEM
- solid-liquid interface
- indium nanoparticles
- mass transfer
- flow cell
- temperature control system
Work with this paper
Most-cited papers in Biochemistry, Genetics and Molecular Biology
- PROTEIN MEASUREMENT WITH THE FOLIN PHENOL REAGENTOliver H. Lowry, NiraJ. Rosebrough, A. Lewis Farr and 1 more · Journal of Biological Chemistry · 1951 · 316,470 citations
- A Rapid and Sensitive Method for the Quantitation of Microgram Quantities of Protein Utilizing the Principle of Protein-Dye BindingM Bradford · Analytical Biochemistry · 1976 · 256,780 citations
- Analysis of Relative Gene Expression Data Using Real-Time Quantitative PCR and the 2−ΔΔCT MethodKenneth J. Livak, Thomas D. Schmittgen · Methods · 2001 · 184,418 citations
- Molecular Cloning: A Laboratory ManualJoseph Sambrook, Elisabeth Fritsch, Tom Maniatis · UCLA - Biblioteca de Ciencias de la Salud · 1989 · 133,493 citations
- Basic Local Alignment Search ToolStephen F. Altschul, Warren R. Gish, Webb Miller and 2 more · Journal of Molecular Biology · 1990 · 100,529 citations
All highly cited Biochemistry, Genetics and Molecular Biology papers
Questions about this paper
How do I cite this paper in APA style?
Jiang, Y., & Liao, H. (2025). Development of MEMS Based In-situ TEM Chips and Applications. Microscopy and Microanalysis, 31(Supplement_1). https://doi.org/10.1093/mam/ozaf048.892
How many times has this paper been cited?
1 times, according to OpenAlex on 16 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access: read the free full text at Microscopy and Microanalysis.
Who wrote this paper?
Youhong Jiang, Hong‐Gang Liao.
What is the DOI of this paper?
10.1093/mam/ozaf048.892. The permanent link is https://doi.org/10.1093/mam/ozaf048.892.
Bibliographic data from OpenAlex (CC0), last checked 16 November 2026. ResearchGuru does not host this paper; the links go to the publisher or the repository that does.