Journal article · 2001 · Open access

Development of a Particle Mechanical Constraint of Variable Stiffness with Application to a Wearable Force Display

Takashi Mitsuda, S. Kuge, Masato Wakabayashi, Sadao Kawamura

Transactions of the Society of Instrument and Control Engineers, 37(12), 1134–1139 · Published 1 January 2001 · DOI 10.9746/sicetr1965.37.1134

Open PDFView at the publisherCite this paper

In brief

“Development of a Particle Mechanical Constraint of Variable Stiffness with Application to a Wearable Force Display” is a 2001 journal article by Takashi Mitsuda and 3 co-authors, published in Transactions of the Society of Instrument and Control Engineers. OpenAlex counts 8 citations as of 22 November 2026. It is open access: the full text is free to read at Transactions of the Society of Instrument and Control Engineers.

Citations
8
Most cited in
2017 (1)
Field-weighted impact
1.17
References
2
Authors
4

Abstract

This paper describes a new mechanical element that varies its stiffness to internal air pressure.The element, named Particle Mechanical Constraint (PMC), is a soft vinyl tube embedded with Styrofoam beads.Its shape varies freely with compression, elongation, bending and twisting.By exhausting the inside air, the PMC solidifies in an arbitrary shape and constrains all degrees-of-freedom.Stiffness and viscosity are adjustable via the inside air pressure.The PMC is light and safe, and therefore can be used as a wearable device.The application of a PMC to a wearable haptic display is described in this paper.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Mitsuda, T., Kuge, S., Wakabayashi, M., & Kawamura, S. (2001). Development of a Particle Mechanical Constraint of Variable Stiffness with Application to a Wearable Force Display. Transactions of the Society of Instrument and Control Engineers, 37(12), 1134–1139. https://doi.org/10.9746/sicetr1965.37.1134

MLA 9

Mitsuda, Takashi, et al. “Development of a Particle Mechanical Constraint of Variable Stiffness with Application to a Wearable Force Display.” Transactions of the Society of Instrument and Control Engineers, vol. 37, no. 12, 2001, pp. 1134–1139. https://doi.org/10.9746/sicetr1965.37.1134.

Chicago

Mitsuda, Takashi, S. Kuge, Masato Wakabayashi, and Sadao Kawamura. 2001. “Development of a Particle Mechanical Constraint of Variable Stiffness with Application to a Wearable Force Display.” Transactions of the Society of Instrument and Control Engineers 37 (12): 1134–1139. https://doi.org/10.9746/sicetr1965.37.1134.

Harvard

Mitsuda, T. et al. (2001) ‘Development of a Particle Mechanical Constraint of Variable Stiffness with Application to a Wearable Force Display’, Transactions of the Society of Instrument and Control Engineers, 37(12), pp. 1134–1139. doi:10.9746/sicetr1965.37.1134.

IEEE

T. Mitsuda, S. Kuge, M. Wakabayashi, and S. Kawamura, “Development of a Particle Mechanical Constraint of Variable Stiffness with Application to a Wearable Force Display,” Transactions of the Society of Instrument and Control Engineers, vol. 37, no. 12, pp. 1134–1139, 2001, doi: 10.9746/sicetr1965.37.1134.

BibTeX

@article{mitsuda2001development,
  title     = {{Development of a Particle Mechanical Constraint of Variable Stiffness with Application to a Wearable Force Display}},
  author    = {Mitsuda, Takashi and Kuge, S. and Wakabayashi, Masato and Kawamura, Sadao},
  journal   = {Transactions of the Society of Instrument and Control Engineers},
  year      = {2001},
  volume    = {37},
  number    = {12},
  pages     = {1134--1139},
  doi       = {10.9746/sicetr1965.37.1134},
  url       = {https://doi.org/10.9746/sicetr1965.37.1134}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
201711
201911
202411

Its field-weighted citation impact is 1.17: it has been cited 1.17 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems

  • variable stiffness
  • haptic display
  • pneumatic actuation
  • air pressure control
  • shape-changing mechanisms
  • wearable devices

Work with this paper

Most-cited papers in Engineering

All highly cited Engineering papers

Questions about this paper

How do I cite this paper in APA style?

Mitsuda, T., Kuge, S., Wakabayashi, M., & Kawamura, S. (2001). Development of a Particle Mechanical Constraint of Variable Stiffness with Application to a Wearable Force Display. Transactions of the Society of Instrument and Control Engineers, 37(12), 1134–1139. https://doi.org/10.9746/sicetr1965.37.1134

How many times has this paper been cited?

8 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Transactions of the Society of Instrument and Control Engineers: sign in and open the PDF from this page.

Who wrote this paper?

Takashi Mitsuda, S. Kuge, Masato Wakabayashi, Sadao Kawamura.

What is the DOI of this paper?

10.9746/sicetr1965.37.1134, permanently at https://doi.org/10.9746/sicetr1965.37.1134. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.