Dissertation · 2023 · Open access
Development and characterization of Ti-10Mo-Mn (0, 2, 4, 6 e 8 w.%) system alloys for biomedical applications
LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · Published 15 August 2023
In brief
“Development and characterization of Ti-10Mo-Mn (0, 2, 4, 6 e 8 w.%) system alloys for biomedical applications” is a 2023 dissertation by Mariana Luna Lourenço, published in LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas). OpenAlex counts 0 citations as of 22 November 2026. It is open access: the full text is free to read at LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas).
- Citations
- 0
- Authors
- 1
Abstract
Ligas de Ti estão sendo extensivamente estudadas para serem utilizadas como biomaterial. Com o aumento da qualidade de vida, a expectativa de vida vem aumentando, e com isso também a demanda por implantes. Cientistas buscam ligas de Ti do tipo β por apresentarem baixo módulo de elasticidade, o que evita o efeito “stress shielding”, que ocorre quando módulo de elasticidade do osso humano tem valor diferente do implante, causando perda de densidade óssea ao redor do material implantado, resultando no afrouxamento do implante, dor ao paciente e a necessidade de cirurgias de reparação. O Ti tornou-se popular para ser usado como biomaterial devido à sua excelente combinação de resistência mecânica, módulo de elasticidade e biocompatibilidade. O Mo aumenta a resistência mecânica do material e está entre os elementos mais cotados para a formação de ligas do tipo β. O Mn aumenta a resistência à corrosão, diminui o modulo de elasticidade, é um elemento essencial para o corpo humano, apresentando boa biocompatibilidade e apresenta baixo custo comparado com o Mo. Visto as boas propriedades dos elementos, fez-se um sistema ternário para estudo. Neste trabalho, previamente foi realizado estudos teóricos para analisar o design das ligas, de forma a avaliar a estabilidade da fase β. O presente trabalho teve como objetivo preparar ligas do sistema Ti-10Mo-xMn (x = 0, 2, 4, 6, 8 %p), e analisar a influência de alguns tratamentos térmicos e do elemento substitucional na estrutura, microestrutura, algumas propriedades mecânicas, e seu caráter citotóxico. As ligas foram obtidas por fusão à arco-voltaico e submetidas a processamentos termomecânicos, como homogeneização, laminação e recozimento. Posteriormente, foram caracterizadas em termos dos aspectos químico, estrutural, microestrutural, eletroquímico e mecânico, com o propósito de melhor compreender a relação microestrutura e propriedades das ligas. As ligas apresentaram uma estrutura cristalina β metaestável, obtendo as fases β, α e α’’ dependendo da concentração dos elementos de liga e das condições de processamento. Os testes de citotoxicidade preliminar indicaram ausência de efeitos deletérios na viabilidade celular com células osteoblásticas em todas as ligas.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Lourenço, M. L. (2023). Development and characterization of Ti-10Mo-Mn (0, 2, 4, 6 e 8 w.%) system alloys for biomedical applications. LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas). https://hdl.handle.net/11449/251160
MLA 9
Lourenço, Mariana Luna. “Development and characterization of Ti-10Mo-Mn (0, 2, 4, 6 e 8 w.%) system alloys for biomedical applications.” LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas), 2023. https://hdl.handle.net/11449/251160.
Chicago
Lourenço, Mariana Luna. 2023. “Development and characterization of Ti-10Mo-Mn (0, 2, 4, 6 e 8 w.%) system alloys for biomedical applications.” LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas). https://hdl.handle.net/11449/251160.
Harvard
Lourenço, M. L. (2023) ‘Development and characterization of Ti-10Mo-Mn (0, 2, 4, 6 e 8 w.%) system alloys for biomedical applications’, LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas). Available at: https://hdl.handle.net/11449/251160.
IEEE
M. L. Lourenço, “Development and characterization of Ti-10Mo-Mn (0, 2, 4, 6 e 8 w.%) system alloys for biomedical applications,” LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas), 2023.
BibTeX
@phdthesis{lourenco2023development,
title = {{Development and characterization of Ti-10Mo-Mn (0, 2, 4, 6 e 8 w.\%) system alloys for biomedical applications}},
author = {Lourenço, Mariana Luna},
year = {2023},
url = {https://hdl.handle.net/11449/251160}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Topic and keywords
Physical Sciences › Materials Science › Materials Chemistry › Titanium Alloys Microstructure and Properties
- beta titanium alloys
- biomedical implants
- stress shielding
- elastic modulus
- β phase stability
- microstructure-property relationship
- mechanical properties
- corrosion resistance
Work with this paper
Most-cited papers in Materials Science
- Electric Field Effect in Atomically Thin Carbon FilmsKostya S. Novoselov, Andre K. Geim, Sergey V. Morozov and 5 more · Science · 2004 · 67,474 citations
- Revised effective ionic radii and systematic studies of interatomic distances in halides and chalcogenidesROBERT D. SHANNON · Acta Crystallographica Section A · 1976 · 66,944 citations
- Ab initio molecular dynamics for liquid metalsGeorg Kresse, J. Häfner · Physical review. B, Condensed matter · 1993 · 46,320 citations
- Helical microtubules of graphitic carbonSumio Iijima · Nature · 1991 · 43,639 citations
- The rise of grapheneAndre K. Geim, Kostya S. Novoselov · Nature Materials · 2007 · 40,328 citations
Questions about this paper
How do I cite this paper in APA style?
Lourenço, M. L. (2023). Development and characterization of Ti-10Mo-Mn (0, 2, 4, 6 e 8 w.%) system alloys for biomedical applications. LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas). https://hdl.handle.net/11449/251160
How many times has this paper been cited?
0 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas): sign in and open the full text from this page.
Who wrote this paper?
Mariana Luna Lourenço.
Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.