Journal article · 2017 · Open access

Determination of trace levels of Cd(II) in tap water samples by anodic stripping voltammetry with an electrografted boron-doped diamond electrode

Chalermpol Innuphat, Pipat Chooto

ScienceAsia, 43(1), 33 · Published 1 January 2017 · DOI 10.2306/scienceasia1513-1874.2017.43.033

Open PDFView at the publisherCite this paper

In brief

“Determination of trace levels of Cd(II) in tap water samples by anodic stripping voltammetry with an electrografted boron-doped diamond electrode” is a 2017 journal article by Chalermpol Innuphat and Pipat Chooto, published in ScienceAsia. OpenAlex counts 17 citations as of 22 November 2026. It is open access: the full text is free to read at ScienceAsia.

Citations
17
Most cited in
2019 (6)
Field-weighted impact
1.22
References
36
Authors
2

Abstract

A boron-doped diamond electrode modified by 0.5 mM 4-aminomethyl benzoic acid was used for electrochemical determination of Cd 2+ in tap water samples by anodic stripping voltammetry.This method is based on the electrochemical reduction of 4-aminomethyl benzoic acid on the electrode followed by the determination of Cd 2+ with a single well-defined reduction peak at -0.72 V versus Ag/AgCl in acetate buffer solutions at pH 6.0.Optimal conditions were established with respect to electrode pretreatment, time accumulation, potential accumulation, scan rate, and pH.Accurate (r 2 = 0.9989, n = 6) calibration curves were obtained for Cd 2+ concentrations ranging between 2 ppb and 50 ppb.Other dissolved metals (Ca, Mg, Zn, Mn, Fe, Cu, Al, Co, Pb, and Ni) have no interference on the Cd 2+ calibration curves.The achieved detection limit was 0.2 ppb.High accuracy and reproducibility of the results as well as excellent stability of the electrode material proves superb capabilities of this Cd 2+ detection system.Recovery in the range of 97-102% further confirmed the usefulness of the proposed method to analyse Cd 2+ in tap water samples.The results with SRM1640 were in good agreement with those by inductively coupled plasma optical emission spectrometry.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Innuphat, C., & Chooto, P. (2017). Determination of trace levels of Cd(II) in tap water samples by anodic stripping voltammetry with an electrografted boron-doped diamond electrode. ScienceAsia, 43(1), 33. https://doi.org/10.2306/scienceasia1513-1874.2017.43.033

MLA 9

Innuphat, Chalermpol, and Pipat Chooto. “Determination of trace levels of Cd(II) in tap water samples by anodic stripping voltammetry with an electrografted boron-doped diamond electrode.” ScienceAsia, vol. 43, no. 1, 2017, p. 33. https://doi.org/10.2306/scienceasia1513-1874.2017.43.033.

Chicago

Innuphat, Chalermpol and Pipat Chooto. 2017. “Determination of trace levels of Cd(II) in tap water samples by anodic stripping voltammetry with an electrografted boron-doped diamond electrode.” ScienceAsia 43 (1): 33. https://doi.org/10.2306/scienceasia1513-1874.2017.43.033.

Harvard

Innuphat, C. and Chooto, P. (2017) ‘Determination of trace levels of Cd(II) in tap water samples by anodic stripping voltammetry with an electrografted boron-doped diamond electrode’, ScienceAsia, 43(1), p. 33. doi:10.2306/scienceasia1513-1874.2017.43.033.

IEEE

C. Innuphat and P. Chooto, “Determination of trace levels of Cd(II) in tap water samples by anodic stripping voltammetry with an electrografted boron-doped diamond electrode,” ScienceAsia, vol. 43, no. 1, p. 33, 2017, doi: 10.2306/scienceasia1513-1874.2017.43.033.

BibTeX

@article{innuphat2017determination,
  title     = {{Determination of trace levels of Cd(II) in tap water samples by anodic stripping voltammetry with an electrografted boron-doped diamond electrode}},
  author    = {Innuphat, Chalermpol and Chooto, Pipat},
  journal   = {ScienceAsia},
  year      = {2017},
  volume    = {43},
  number    = {1},
  pages     = {33},
  doi       = {10.2306/scienceasia1513-1874.2017.43.033},
  url       = {https://doi.org/10.2306/scienceasia1513-1874.2017.43.033}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
201711
201811
201966
202011
202122
202211
202322
202411
202511
202611

Its field-weighted citation impact is 1.22: it has been cited 1.22 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications

  • cadmium determination
  • trace metal analysis
  • tap water
  • anodic stripping voltammetry
  • boron-doped diamond electrode
  • electrografting
  • electrochemical reduction
  • electrode modification

Work with this paper

Most-cited papers in Chemistry

All highly cited Chemistry papers

Questions about this paper

How do I cite this paper in APA style?

Innuphat, C., & Chooto, P. (2017). Determination of trace levels of Cd(II) in tap water samples by anodic stripping voltammetry with an electrografted boron-doped diamond electrode. ScienceAsia, 43(1), 33. https://doi.org/10.2306/scienceasia1513-1874.2017.43.033

How many times has this paper been cited?

17 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at ScienceAsia: sign in and open the PDF from this page.

Who wrote this paper?

Chalermpol Innuphat, Pipat Chooto.

What is the DOI of this paper?

10.2306/scienceasia1513-1874.2017.43.033, permanently at https://doi.org/10.2306/scienceasia1513-1874.2017.43.033. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.