“Determination of Lead and Cadmium in Water Samples by Adsorptive Stripping Voltammetry Using a Bismuth film/1- Nitroso-2-Napthol/Nafion Modified Glassy Carbon Electrode” is a 2016 journal article by Rodrigo Segura and 5 co-authors, published in International Journal of Electrochemical Science. OpenAlex counts 17 citations as of 22 November 2026. It is open access under a CC BY-NC-ND licence: the full text is free to read at International Journal of Electrochemical Science.

Citations
17
Most cited in
2017 (7)
Field-weighted impact
1.61
References
54
Authors
6

Abstract

The application and validation of a glassy carbon electrode modified with Nafion, 1-nitroso-2-naphthol and bismuth film (GC/NF-NN/BiFE) was studied using adsorptive stripping voltammetry (AdSV) for the determination of Pb2+ and Cd2+ in tap water. The parameters studied and optimized were pH, 1- nitroso-2-naphthol concentration (CNN), Nafion concentration (CNF), adsorption potential (Eacc) and adsorption time (tacc). Optimal conditions were pH 4.5 (acetate buffer solution 0.10 mol L-1); Eacc: -1.30 V; tacc: 120 s; CNN : 0.10% w/v, CNF: 0.50 wt %. The detection and quantification limits were 0.08 and 0.29 pg L-1 for Pb2+ and 0.07 and 0.24 pg L-1 for Cd2+, with a linear range of 10 to 70 pg L-1. Certified reference material (ICP Multi Element Standard) and synthetic samples were determined to validate the methodology, with satisfactory results. The stripping voltammetry method was tested on tap water.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Segura, R., Pizarro, J., Oyarzún, M. P., Castillo, A. D., Díaz, K. J., & Placencio, A. B. (2016). Determination of Lead and Cadmium in Water Samples by Adsorptive Stripping Voltammetry Using a Bismuth film/1- Nitroso-2-Napthol/Nafion Modified Glassy Carbon Electrode. International Journal of Electrochemical Science, 11(2), 1707–1719. https://doi.org/10.1016/s1452-3981(23)15954-2

MLA 9

Segura, Rodrigo, et al. “Determination of Lead and Cadmium in Water Samples by Adsorptive Stripping Voltammetry Using a Bismuth film/1- Nitroso-2-Napthol/Nafion Modified Glassy Carbon Electrode.” International Journal of Electrochemical Science, vol. 11, no. 2, 2016, pp. 1707–1719. https://doi.org/10.1016/s1452-3981(23)15954-2.

Chicago

Segura, Rodrigo, Jaime Pizarro, María Paz Oyarzún, Alejandra D. Castillo, Karina J. Díaz, and Alan B. Placencio. 2016. “Determination of Lead and Cadmium in Water Samples by Adsorptive Stripping Voltammetry Using a Bismuth film/1- Nitroso-2-Napthol/Nafion Modified Glassy Carbon Electrode.” International Journal of Electrochemical Science 11 (2): 1707–1719. https://doi.org/10.1016/s1452-3981(23)15954-2.

Harvard

Segura, R. et al. (2016) ‘Determination of Lead and Cadmium in Water Samples by Adsorptive Stripping Voltammetry Using a Bismuth film/1- Nitroso-2-Napthol/Nafion Modified Glassy Carbon Electrode’, International Journal of Electrochemical Science, 11(2), pp. 1707–1719. doi:10.1016/s1452-3981(23)15954-2.

IEEE

R. Segura, J. Pizarro, M. P. Oyarzún, A. D. Castillo, K. J. Díaz, and A. B. Placencio, “Determination of Lead and Cadmium in Water Samples by Adsorptive Stripping Voltammetry Using a Bismuth film/1- Nitroso-2-Napthol/Nafion Modified Glassy Carbon Electrode,” International Journal of Electrochemical Science, vol. 11, no. 2, pp. 1707–1719, 2016, doi: 10.1016/s1452-3981(23)15954-2.

BibTeX

@article{segura2016determination,
  title     = {{Determination of Lead and Cadmium in Water Samples by Adsorptive Stripping Voltammetry Using a Bismuth film/1- Nitroso-2-Napthol/Nafion Modified Glassy Carbon Electrode}},
  author    = {Segura, Rodrigo and Pizarro, Jaime and Oyarzún, María Paz and Castillo, Alejandra D. and Díaz, Karina J. and Placencio, Alan B.},
  journal   = {International Journal of Electrochemical Science},
  year      = {2016},
  volume    = {11},
  number    = {2},
  pages     = {1707--1719},
  doi       = {10.1016/s1452-3981(23)15954-2},
  url       = {https://doi.org/10.1016/s1452-3981(23)15954-2}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
201611
201777
201822
201911
202033
202111
202211
202611

Its field-weighted citation impact is 1.61: it has been cited 1.61 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications

  • lead determination
  • cadmium determination
  • adsorptive stripping voltammetry
  • bismuth film electrode
  • 1-nitroso-2-naphthol
  • Nafion-modified glassy carbon electrode
  • modified electrode
  • tap water analysis

Work with this paper

Most-cited papers in Chemistry

All highly cited Chemistry papers

Questions about this paper

How do I cite this paper in APA style?

Segura, R., Pizarro, J., Oyarzún, M. P., Castillo, A. D., Díaz, K. J., & Placencio, A. B. (2016). Determination of Lead and Cadmium in Water Samples by Adsorptive Stripping Voltammetry Using a Bismuth film/1- Nitroso-2-Napthol/Nafion Modified Glassy Carbon Electrode. International Journal of Electrochemical Science, 11(2), 1707–1719. https://doi.org/10.1016/s1452-3981(23)15954-2

How many times has this paper been cited?

17 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at International Journal of Electrochemical Science: sign in and open the full text from this page.

Who wrote this paper?

Rodrigo Segura, Jaime Pizarro, María Paz Oyarzún, Alejandra D. Castillo, Karina J. Díaz, Alan B. Placencio.

What is the DOI of this paper?

10.1016/s1452-3981(23)15954-2, permanently at https://doi.org/10.1016/s1452-3981(23)15954-2. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.