Journal article · 2019 · Open access

Detection of Cd (II) and Pb (II) by anodic stripping voltammetry using glassy carbon electrodes modified with Ag-Hg and Ag-Bi bimetallic alloyed

Danny Valera, Mireya Sánchez, José Ramón Domínguez, Patricio J. Espinoza-Montero, Carlos Velasco-Medina, Patricio Carrera, Lenys Fernández

NOVASINERGIA REVISTA DIGITAL DE CIENCIA INGENIERÍA Y TECNOLOGÍA, 2(2), 75–83 · Published 10 December 2019 · DOI 10.37135/unach.ns.001.04.08

Open PDFView at the publisherCite this paper

In brief

“Detection of Cd (II) and Pb (II) by anodic stripping voltammetry using glassy carbon electrodes modified with Ag-Hg and Ag-Bi bimetallic alloyed” is a 2019 journal article by Danny Valera and 6 co-authors, published in NOVASINERGIA REVISTA DIGITAL DE CIENCIA INGENIERÍA Y TECNOLOGÍA. OpenAlex counts 2 citations as of 22 November 2026. It is open access under a CC BY-NC licence: the full text is free to read at NOVASINERGIA REVISTA DIGITAL DE CIENCIA INGENIERÍA Y TECNOLOGÍA.

Citations
2
Most cited in
2021 (1)
Field-weighted impact
0.12
References
25
Authors
7

Abstract

Presentamos la evaluación de los electrodos de carbono vítreo (GC) modificados con películas de Nafion (Nf) y depósitos bimetálicos de aleaciones Ag-Hg y Ag-Bi. La mayoría de los bimetálicos depositados, con un tamaño promedio de aproximadamente 150 nm, se dispersaron e incrustaron uniformemente dentro de la red del Nafion, mientras que una cantidad mucho menor permaneció encima de las incrustadas sin ninguna orientación regular, como lo indica imágenes de microscopía electrónica de barrido (SEM) y microscopía de fuerza atómica (AFM). Las pruebas de sensibilidad para el electrodo modificado AgBiNf/GC produjeron límites de detección (DL), basados en la variabilidad de una solución en blanco (criterio de 3 s), de 0,78 y 0,66 μg L-1 para Cd (II) y Pb (II), respectivamente; mientras que el DL sobre el electrodo modificado AgHgNf/GC fue 0,17 y 0,24 μg L-1 para Cd (II) y Pb (II), respectivamente. La precisión de la metodología por voltametría de redisolución anódica se verificó mediante el cálculo de porcentajes de recuperación de los dos analitos, expresados como error relativo. Se logró una recuperación del 99% al 92%.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Valera, D., Sánchez, M., Domínguez, J. R., Espinoza-Montero, P. J., Velasco-Medina, C., Carrera, P., & Fernández, L. (2019). Detection of Cd (II) and Pb (II) by anodic stripping voltammetry using glassy carbon electrodes modified with Ag-Hg and Ag-Bi bimetallic alloyed. NOVASINERGIA REVISTA DIGITAL DE CIENCIA INGENIERÍA Y TECNOLOGÍA, 2(2), 75–83. https://doi.org/10.37135/unach.ns.001.04.08

MLA 9

Valera, Danny, et al. “Detection of Cd (II) and Pb (II) by anodic stripping voltammetry using glassy carbon electrodes modified with Ag-Hg and Ag-Bi bimetallic alloyed.” NOVASINERGIA REVISTA DIGITAL DE CIENCIA INGENIERÍA Y TECNOLOGÍA, vol. 2, no. 2, 2019, pp. 75–83. https://doi.org/10.37135/unach.ns.001.04.08.

Chicago

Valera, Danny, Mireya Sánchez, José Ramón Domínguez, Patricio J. Espinoza-Montero, Carlos Velasco-Medina, Patricio Carrera, and Lenys Fernández. 2019. “Detection of Cd (II) and Pb (II) by anodic stripping voltammetry using glassy carbon electrodes modified with Ag-Hg and Ag-Bi bimetallic alloyed.” NOVASINERGIA REVISTA DIGITAL DE CIENCIA INGENIERÍA Y TECNOLOGÍA 2 (2): 75–83. https://doi.org/10.37135/unach.ns.001.04.08.

Harvard

Valera, D. et al. (2019) ‘Detection of Cd (II) and Pb (II) by anodic stripping voltammetry using glassy carbon electrodes modified with Ag-Hg and Ag-Bi bimetallic alloyed’, NOVASINERGIA REVISTA DIGITAL DE CIENCIA INGENIERÍA Y TECNOLOGÍA, 2(2), pp. 75–83. doi:10.37135/unach.ns.001.04.08.

IEEE

D. Valera et al., “Detection of Cd (II) and Pb (II) by anodic stripping voltammetry using glassy carbon electrodes modified with Ag-Hg and Ag-Bi bimetallic alloyed,” NOVASINERGIA REVISTA DIGITAL DE CIENCIA INGENIERÍA Y TECNOLOGÍA, vol. 2, no. 2, pp. 75–83, 2019, doi: 10.37135/unach.ns.001.04.08.

BibTeX

@article{valera2019detection,
  title     = {{Detection of Cd (II) and Pb (II) by anodic stripping voltammetry using glassy carbon electrodes modified with Ag-Hg and Ag-Bi bimetallic alloyed}},
  author    = {Valera, Danny and Sánchez, Mireya and Domínguez, José Ramón and Espinoza-Montero, Patricio J. and Velasco-Medina, Carlos and Carrera, Patricio and Fernández, Lenys},
  journal   = {NOVASINERGIA REVISTA DIGITAL DE CIENCIA INGENIERÍA Y TECNOLOGÍA},
  year      = {2019},
  volume    = {2},
  number    = {2},
  pages     = {75--83},
  doi       = {10.37135/unach.ns.001.04.08},
  url       = {https://doi.org/10.37135/unach.ns.001.04.08}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications

  • cadmium determination
  • lead ion detection
  • anodic stripping voltammetry
  • glassy carbon electrode
  • Nafion-modified electrode
  • detection limit

Work with this paper

Most-cited papers in Chemistry

All highly cited Chemistry papers

Questions about this paper

How do I cite this paper in APA style?

Valera, D., Sánchez, M., Domínguez, J. R., Espinoza-Montero, P. J., Velasco-Medina, C., Carrera, P., & Fernández, L. (2019). Detection of Cd (II) and Pb (II) by anodic stripping voltammetry using glassy carbon electrodes modified with Ag-Hg and Ag-Bi bimetallic alloyed. NOVASINERGIA REVISTA DIGITAL DE CIENCIA INGENIERÍA Y TECNOLOGÍA, 2(2), 75–83. https://doi.org/10.37135/unach.ns.001.04.08

How many times has this paper been cited?

2 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at NOVASINERGIA REVISTA DIGITAL DE CIENCIA INGENIERÍA Y TECNOLOGÍA: sign in and open the PDF from this page.

Who wrote this paper?

Danny Valera, Mireya Sánchez, José Ramón Domínguez, Patricio J. Espinoza-Montero, Carlos Velasco-Medina, Patricio Carrera, Lenys Fernández.

What is the DOI of this paper?

10.37135/unach.ns.001.04.08, permanently at https://doi.org/10.37135/unach.ns.001.04.08. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.