Journal article · 2019 · Open access
Design process and simulation testing of a shape memory alloy actuated robotic microgripper
Microsystem Technologies, 26(3), 885–900 · Published 3 September 2019 · DOI 10.1007/s00542-019-04599-6
In brief
“Design process and simulation testing of a shape memory alloy actuated robotic microgripper” is a 2019 journal article by H. Llewellyn-Evans and 2 co-authors, published in Microsystem Technologies. OpenAlex counts 18 citations as of 22 November 2026. It is open access under a CC BY licence: the full text is free to read at Microsystem Technologies.
- Citations
- 18
- Most cited in
- 2026 (5)
- Field-weighted impact
- 0.51
- References
- 29
- Authors
- 3
Abstract
Microgrippers are commonly used for micromanipulation of micro-objects with dimensions from 1 to 100 µm and attain features of reliable accuracy, low cost, wide jaw aperture and variable applied force. This paper studies the design process, simulation, and testing of a microgripper which can manipulate and assemble a platinum resistance temperature probe, made from a 25 µm diameter platinum wire, a 20 mm diameter tinned copper wire, and a printed circuit board type connector. Various microgripper structures and actuator types were researched and reviewed to determine the most suitable design for the required micromanipulation task. Operation tests using SolidWorks and ANSYS software were conducted to test a parallelogram structure with flexible single-notch hinges. The best suited material was found to be Aluminium alloy 7075-T6 as it was capable of producing a large jaw tip displacement of 0.7 mm without exceeding its tensile yield strength limit. A shape memory alloy was chosen as a choice of actuator to close the microgripper jaws. To ensure a repeatably accurate datum point, the final microgripper consisted of a fixed arm and a flexible arm. An optimisation process using ANSYS studied the hinge thickness and radius dimensions of the microgripper which improved its deflection whilst reducing the experienced stress.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Llewellyn-Evans, H., Griffiths, C. A., & Fahmy, A. (2019). Design process and simulation testing of a shape memory alloy actuated robotic microgripper. Microsystem Technologies, 26(3), 885–900. https://doi.org/10.1007/s00542-019-04599-6
MLA 9
Llewellyn-Evans, H., et al. “Design process and simulation testing of a shape memory alloy actuated robotic microgripper.” Microsystem Technologies, vol. 26, no. 3, 2019, pp. 885–900. https://doi.org/10.1007/s00542-019-04599-6.
Chicago
Llewellyn-Evans, H., Christian Andrew Griffiths, and Ashraf Fahmy. 2019. “Design process and simulation testing of a shape memory alloy actuated robotic microgripper.” Microsystem Technologies 26 (3): 885–900. https://doi.org/10.1007/s00542-019-04599-6.
Harvard
Llewellyn-Evans, H., Griffiths, C. A. and Fahmy, A. (2019) ‘Design process and simulation testing of a shape memory alloy actuated robotic microgripper’, Microsystem Technologies, 26(3), pp. 885–900. doi:10.1007/s00542-019-04599-6.
IEEE
H. Llewellyn-Evans, C. A. Griffiths, and A. Fahmy, “Design process and simulation testing of a shape memory alloy actuated robotic microgripper,” Microsystem Technologies, vol. 26, no. 3, pp. 885–900, 2019, doi: 10.1007/s00542-019-04599-6.
BibTeX
@article{llewellynevans2019design,
title = {{Design process and simulation testing of a shape memory alloy actuated robotic microgripper}},
author = {Llewellyn-Evans, H. and Griffiths, Christian Andrew and Fahmy, Ashraf},
journal = {Microsystem Technologies},
year = {2019},
volume = {26},
number = {3},
pages = {885--900},
doi = {10.1007/s00542-019-04599-6},
url = {https://doi.org/10.1007/s00542-019-04599-6}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Citations by year
| Year | Citations | Share of the best year |
|---|---|---|
| 2020 | 2 | |
| 2021 | 3 | |
| 2022 | 1 | |
| 2023 | 4 | |
| 2024 | 3 | |
| 2026 | 5 |
Its field-weighted citation impact is 0.51: it has been cited 0.51 times as often as the average work of the same field, type and year (1.00 is the world average).
Topic and keywords
Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
- shape memory alloy actuators
- micromanipulation
- microassembly
- flexible hinges
- jaw displacement
- stress reduction
Work with this paper
Most-cited papers in Engineering
- A Closed‐form Equation for Predicting the Hydraulic Conductivity of Unsaturated SoilsMartinus Th. van Genuchten · Soil Science Society of America Journal · 1980 · 28,197 citations
- An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experimentsW. C. Oliver, George M. Pharr · Journal of materials research/Pratt's guide to venture capital sources · 1992 · 27,379 citations
- Digital communicationsOwen Bishop · Routledge eBooks · 2007 · 24,890 citations
- The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysisNorden Eh Huang, Zhengwei Shen, Steven R. Long and 6 more · Proceedings of the Royal Society A Mathematical Physical and Engineering Sciences · 1998 · 24,008 citations
- Numerical Heat Transfer and Fluid FlowSuhas V. Patankar · CRC Press eBooks · 2018 · 23,491 citations
Questions about this paper
How do I cite this paper in APA style?
Llewellyn-Evans, H., Griffiths, C. A., & Fahmy, A. (2019). Design process and simulation testing of a shape memory alloy actuated robotic microgripper. Microsystem Technologies, 26(3), 885–900. https://doi.org/10.1007/s00542-019-04599-6
How many times has this paper been cited?
18 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at Microsystem Technologies: sign in and open the PDF from this page.
Who wrote this paper?
H. Llewellyn-Evans, Christian Andrew Griffiths, Ashraf Fahmy.
What is the DOI of this paper?
10.1007/s00542-019-04599-6, permanently at https://doi.org/10.1007/s00542-019-04599-6. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.