Journal article · 2009 · Open access

Design of an Actuated Volume Compensating SLS Prosthetic Socket

J. Montgomery, Meagan Vaughan, Richard Crawford

Journal of Medical Devices, 3(2), 027534 · Published 1 June 2009 · DOI 10.1115/1.3147490

Open PDFView at the publisherCite this paper

In brief

“Design of an Actuated Volume Compensating SLS Prosthetic Socket” is a 2009 journal article by J. Montgomery and 2 co-authors, published in Journal of Medical Devices. OpenAlex counts 0 citations as of 22 November 2026. It is open access: the full text is free to read at Journal of Medical Devices.

Citations
0
Authors
3

Abstract

Studies have shown residual limb volume can vary −11% to 7% in a single day due to changing activity level or weight. However, volume changes of only 3% to 5% can cause users to have difficulty putting on their prosthetic socket. Many existing volume compensation methods are cumbersome, rely on the amputee to maintain the appropriate pressure level, or allow only for a decrease in limb volume. Automatic compensation for volume gain and loss is therefore needed; however, the complexity of designing such sockets renders a traditional fabrication methods cost prohibitive or technically infeasible. Selective Laser Sintering (SLS), a rapid manufacturing (RM) technology, addresses both of these concerns. SLS is a layer-based RM technology that relies on a high power laser to fuse powder particles into a solid object. Minute detail, directly from a 3D CAD model, is possible and a technique has been established for manufacturing prosthetic sockets with passive compliant regions using SLS. Based on this SLS RM technique, steps toward developing a transtibial Nylon prosthetic socket that automatically adapts to volumetric changes in a residual limb will be described. A design methodology was developed to use RM including concept generation, refinement, and final verification. In concept generation, analogies, such as “Chinese Fingertraps” and balloons, were coupled with a review of socket designs in literature and industry and interviews with prosthetists. Inflation of a bladder integrated into the wall of a SLS socket is one of the promising design concepts generated, but the concept needs further refinement. In order to confidently design an inflatable SLS prosthetic, it is critical to understand the relationship between applied pressure and deflection. A testing specimen—5.08 cm diameter thinwalled membrane—was designed to simulate a bladder integrated into the wall of a SLS socket. Several thicknesses were also used to investigate the effects of this parameter on inflation. Preliminary tests were conducted using compressed air for quantifying pressure vs. displacement. During the tests, leakage through open porosity (due to low density) was detected. Density is strongly related to energy transmitted to the part during sintering. The energy concentration is quantified as the Andrew's Number (AN), the inverse relationship of laser power (LP) to laser scanning speed (SSP) and scan spacing (SS). Therefore, to determine the optimal AN—and therefore increase density—an experiment varying LP and SS (SSP is a manufacturer setting) to determine their effects on apparent density and tensile strength was completed. The optimal AN, 1.63 J/cm2 for Nylon 12 powder, was based on highest apparent density and tensile strength. Using this AN, additional…

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Montgomery, J., Vaughan, M., & Crawford, R. (2009). Design of an Actuated Volume Compensating SLS Prosthetic Socket. Journal of Medical Devices, 3(2), 027534. https://doi.org/10.1115/1.3147490

MLA 9

Montgomery, J., et al. “Design of an Actuated Volume Compensating SLS Prosthetic Socket.” Journal of Medical Devices, vol. 3, no. 2, 2009, p. 027534. https://doi.org/10.1115/1.3147490.

Chicago

Montgomery, J., Meagan Vaughan, and Richard Crawford. 2009. “Design of an Actuated Volume Compensating SLS Prosthetic Socket.” Journal of Medical Devices 3 (2): 027534. https://doi.org/10.1115/1.3147490.

Harvard

Montgomery, J., Vaughan, M. and Crawford, R. (2009) ‘Design of an Actuated Volume Compensating SLS Prosthetic Socket’, Journal of Medical Devices, 3(2), p. 027534. doi:10.1115/1.3147490.

IEEE

J. Montgomery, M. Vaughan, and R. Crawford, “Design of an Actuated Volume Compensating SLS Prosthetic Socket,” Journal of Medical Devices, vol. 3, no. 2, p. 027534, 2009, doi: 10.1115/1.3147490.

BibTeX

@article{montgomery2009design,
  title     = {{Design of an Actuated Volume Compensating SLS Prosthetic Socket}},
  author    = {Montgomery, J. and Vaughan, Meagan and Crawford, Richard},
  journal   = {Journal of Medical Devices},
  year      = {2009},
  volume    = {3},
  number    = {2},
  pages     = {027534},
  doi       = {10.1115/1.3147490},
  url       = {https://doi.org/10.1115/1.3147490}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics

  • selective laser sintering
  • prosthetic socket
  • volume compensation
  • residual limb volume
  • inflatable bladder
  • transtibial amputation
  • laser power
  • scan spacing

Work with this paper

Most-cited papers in Engineering

All highly cited Engineering papers

Questions about this paper

How do I cite this paper in APA style?

Montgomery, J., Vaughan, M., & Crawford, R. (2009). Design of an Actuated Volume Compensating SLS Prosthetic Socket. Journal of Medical Devices, 3(2), 027534. https://doi.org/10.1115/1.3147490

How many times has this paper been cited?

0 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Journal of Medical Devices: sign in and open the PDF from this page.

Who wrote this paper?

J. Montgomery, Meagan Vaughan, Richard Crawford.

What is the DOI of this paper?

10.1115/1.3147490, permanently at https://doi.org/10.1115/1.3147490. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.