Journal article · 2022 · Open access

Design and Testing of a New Piezoelectric-Actuated Symmetric Compliant Microgripper

Zekui Lyu, Qingsong Xu

Actuators, 11(3), 77 · Published 3 March 2022 · DOI 10.3390/act11030077

Open PDFView at the publisherCite this paper

In brief

“Design and Testing of a New Piezoelectric-Actuated Symmetric Compliant Microgripper” is a 2022 journal article by Zekui Lyu and Qingsong Xu, published in Actuators. OpenAlex counts 21 citations as of 22 November 2026, which puts it in the top 7% of works published in 2022 by citations. It is open access under a CC BY licence: the full text is free to read at Actuators.

Citations
21
Most cited in
2024 (7)
Field-weighted impact
1.46
References
30
Authors
2

Abstract

Precise and stable operations in micromanipulation and microassembly require a high-performance microgripper. To improve the predominant static and dynamic characteristics, a novel piezoelectric-actuated compliant microgripper is designed, analyzed, and tested in this paper. The microgripper realizes a large gripping stroke by integrating a compliant bridge mechanism, an L-shaped mechanism, and a levered parallelogram mechanism. Optimization technology based on response surface analysis is applied to demonstrate the influence of structural parameters on the microgripper performance. Simulation results of finite element analysis reveal the superior performance of the designed microgripper in terms of gripping displacement, mechanism stiffness, equivalent stress, and natural frequency. A gripper prototype has been fabricated, and experimental studies have been conducted to test the microgripper’s physical properties. Experimental results show that the microgripper can grasp micro-objects with a maximum jaw motion stroke of 312.8 μm, natural frequency of 786 Hz, motion resolution of ±0.6 μm, and force resolution of ±1.69 mN. The gripping tests of an optical fiber with a diameter of 200 μm and a metal sheet with a thickness of 100 μm have been performed to demonstrate its gripping capability with position and force control.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Lyu, Z., & Xu, Q. (2022). Design and Testing of a New Piezoelectric-Actuated Symmetric Compliant Microgripper. Actuators, 11(3), 77. https://doi.org/10.3390/act11030077

MLA 9

Lyu, Zekui, and Qingsong Xu. “Design and Testing of a New Piezoelectric-Actuated Symmetric Compliant Microgripper.” Actuators, vol. 11, no. 3, 2022, p. 77. https://doi.org/10.3390/act11030077.

Chicago

Lyu, Zekui and Qingsong Xu. 2022. “Design and Testing of a New Piezoelectric-Actuated Symmetric Compliant Microgripper.” Actuators 11 (3): 77. https://doi.org/10.3390/act11030077.

Harvard

Lyu, Z. and Xu, Q. (2022) ‘Design and Testing of a New Piezoelectric-Actuated Symmetric Compliant Microgripper’, Actuators, 11(3), p. 77. doi:10.3390/act11030077.

IEEE

Z. Lyu and Q. Xu, “Design and Testing of a New Piezoelectric-Actuated Symmetric Compliant Microgripper,” Actuators, vol. 11, no. 3, p. 77, 2022, doi: 10.3390/act11030077.

BibTeX

@article{lyu2022design,
  title     = {{Design and Testing of a New Piezoelectric-Actuated Symmetric Compliant Microgripper}},
  author    = {Lyu, Zekui and Xu, Qingsong},
  journal   = {Actuators},
  year      = {2022},
  volume    = {11},
  number    = {3},
  pages     = {77},
  doi       = {10.3390/act11030077},
  url       = {https://doi.org/10.3390/act11030077}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
202222
202344
202477
202555
202633

Its field-weighted citation impact is 1.46: it has been cited 1.46 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Physical Sciences › Engineering › Control and Systems Engineering › Piezoelectric Actuators and Control

  • piezoelectric actuation
  • micromanipulation
  • microassembly
  • response surface analysis
  • natural frequencies
  • position/force control

Work with this paper

Most-cited papers in Engineering

All highly cited Engineering papers

Questions about this paper

How do I cite this paper in APA style?

Lyu, Z., & Xu, Q. (2022). Design and Testing of a New Piezoelectric-Actuated Symmetric Compliant Microgripper. Actuators, 11(3), 77. https://doi.org/10.3390/act11030077

How many times has this paper been cited?

21 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Actuators: sign in and open the PDF from this page.

Who wrote this paper?

Zekui Lyu, Qingsong Xu.

What is the DOI of this paper?

10.3390/act11030077, permanently at https://doi.org/10.3390/act11030077. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.