“Design and technical construction of a tactile display for sensory feedback in a hand prosthesis system” is a 2010 journal article by Christian Antfolk and 4 co-authors, published in BioMedical Engineering OnLine. OpenAlex counts 50 citations as of 22 November 2026. It is open access under a CC BY licence: the full text is free to read at BioMedical Engineering OnLine.

Citations
50
Most cited in
2018 (4)
Field-weighted impact
1.80
References
24
Authors
5

Abstract

BACKGROUND: The users of today's commercial prosthetic hands are not given any conscious sensory feedback. To overcome this deficiency in prosthetic hands we have recently proposed a sensory feedback system utilising a "tactile display" on the remaining amputation residual limb acting as man-machine interface. Our system uses the recorded pressure in a hand prosthesis and feeds back this pressure onto the forearm skin. Here we describe the design and technical solution of the sensory feedback system aimed at hand prostheses for trans-radial/humeral amputees. Critical parameters for the sensory feedback system were investigated. METHODS: A sensory feedback system consisting of five actuators, control electronics and a test application running on a computer has been designed and built. Firstly, we investigate which force levels were applied to the forearm skin of the user while operating the sensory feedback system. Secondly, we study if the proposed system could be used together with a myoelectric control system. The displacement of the skin caused by the sensory feedback system would generate artefacts in the recorded myoelectric signals. Accordingly, EMG recordings were performed and an analysis of the these are included. The sensory feedback system was also preliminarily evaluated in a laboratory setting on two healthy non-amputated test subjects with a computer generating the stimuli, with regards to spatial resolution and force discrimination. RESULTS: We showed that the sensory feedback system generated approximately proportional force to the angle of control. The system can be used together with a myoelectric system as the artefacts, generated by the actuators, were easily removed using a simple filter. Furthermore, the application of the system on two test subjects showed that they were able to discriminate tactile sensation with regards to spatial resolution and level of force. CONCLUSIONS: The results of these initial experiments in non-amputees indicate that the proposed tactile display, in its simple form, can be used to relocate tactile input from an artificial hand to the forearm and that the system can coexist with a myoelectric control systems. The proposed system may be a valuable addition to users of myoelectric prosthesis providing conscious sensory feedback during manipulation of objects.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Antfolk, C., Balkenius, C., Lundborg, G., Rosén, B., & Sebelius, F. (2010). Design and technical construction of a tactile display for sensory feedback in a hand prosthesis system. BioMedical Engineering OnLine, 9(1), 50. https://doi.org/10.1186/1475-925x-9-50

MLA 9

Antfolk, Christian, et al. “Design and technical construction of a tactile display for sensory feedback in a hand prosthesis system.” BioMedical Engineering OnLine, vol. 9, no. 1, 2010, p. 50. https://doi.org/10.1186/1475-925x-9-50.

Chicago

Antfolk, Christian, Christian Balkenius, Göran Lundborg, Birgitta Rosén, and Fredrik Sebelius. 2010. “Design and technical construction of a tactile display for sensory feedback in a hand prosthesis system.” BioMedical Engineering OnLine 9 (1): 50. https://doi.org/10.1186/1475-925x-9-50.

Harvard

Antfolk, C. et al. (2010) ‘Design and technical construction of a tactile display for sensory feedback in a hand prosthesis system’, BioMedical Engineering OnLine, 9(1), p. 50. doi:10.1186/1475-925x-9-50.

IEEE

C. Antfolk, C. Balkenius, G. Lundborg, B. Rosén, and F. Sebelius, “Design and technical construction of a tactile display for sensory feedback in a hand prosthesis system,” BioMedical Engineering OnLine, vol. 9, no. 1, p. 50, 2010, doi: 10.1186/1475-925x-9-50.

BibTeX

@article{antfolk2010design,
  title     = {{Design and technical construction of a tactile display for sensory feedback in a hand prosthesis system}},
  author    = {Antfolk, Christian and Balkenius, Christian and Lundborg, Göran and Rosén, Birgitta and Sebelius, Fredrik},
  journal   = {BioMedical Engineering OnLine},
  year      = {2010},
  volume    = {9},
  number    = {1},
  pages     = {50},
  doi       = {10.1186/1475-925x-9-50},
  url       = {https://doi.org/10.1186/1475-925x-9-50}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
201722
201844
201933
202033
202144
202233
202322
202422
202511
202633

Its field-weighted citation impact is 1.80: it has been cited 1.80 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics

  • tactile display
  • sensory feedback
  • prosthetic hand
  • myoelectric control
  • transradial amputation
  • spatial resolution
  • human-machine interaction
  • residual limb

Work with this paper

Most-cited papers in Engineering

All highly cited Engineering papers

Questions about this paper

How do I cite this paper in APA style?

Antfolk, C., Balkenius, C., Lundborg, G., Rosén, B., & Sebelius, F. (2010). Design and technical construction of a tactile display for sensory feedback in a hand prosthesis system. BioMedical Engineering OnLine, 9(1), 50. https://doi.org/10.1186/1475-925x-9-50

How many times has this paper been cited?

50 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at BioMedical Engineering OnLine: sign in and open the PDF from this page.

Who wrote this paper?

Christian Antfolk, Christian Balkenius, Göran Lundborg, Birgitta Rosén, Fredrik Sebelius.

What is the DOI of this paper?

10.1186/1475-925x-9-50, permanently at https://doi.org/10.1186/1475-925x-9-50. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.