“Design and assessment of a low-cost, electromyographically controlled, prosthetic hand” is a 2013 journal article by Gaetano Dario Gargiulo and 7 co-authors, published in Medical Devices Evidence and Research. OpenAlex counts 32 citations as of 22 November 2026. It is open access under a CC BY-NC licence: the full text is free to read at Medical Devices Evidence and Research.
- Citations
- 32
- Most cited in
- 2023 (5)
- Field-weighted impact
- 0.85
- References
- 27
- Authors
- 8
Abstract
The study reported here explored the design and realization of a low-cost, electromyographically controlled hand prosthesis for amputees living in developing countries. The developed prosthesis is composed of a light aluminum structure with opposing fingers connected to a DC motor that imparts only the movement of grasp. Problems associated with surface electromyographic signal acquisition and processing, motor control, and evaluation of grasp force were addressed, with the goal of minimizing cost and ensuring easy assembly. Simple analog front ends amplify and condition the electromyographic signals registered from two antagonist muscles by surface electrodes. Analog signals are sampled at 1 kHz and processed by a microcontroller that drives the motor with a supply voltage proportional to the muscular contraction, performing the opening and closing of the opposing fingers. Reliable measurements of the level of muscle contractions were obtained by specific digital processing: real-time operators implementing the root mean square value, mean absolute value, standard deviation, and mean absolute differential value were compared in terms of efficiency to estimate the EMG envelope, computational load, and time delay. The mean absolute value operator was adopted at a time window of 64 milliseconds. A suitable calibration procedure was proposed to overcome problems associated with the wide variation of electromyograph amplitude and background noise depending on the specific patient's muscles selected. A pulse-width modulated signal drives the DC motor, allowing closing and opening of the prosthesis. The relationship between the motor-driver signal and the actual hand-grasp force developed by the prosthesis was measured using a hand-held grip dynamometer. The resulting force was proportional to current for moderate values of current and then saturated. The motor torque, and, in turn, the force elicited, can be measured by sensing the current absorbed by the motor. Therefore, the grasp force can be opportunely limited or controlled. The cost of the only electronic and mechanical components of the electromyographically controlled hand was about US$50; other costs, such as the cost of labor to assemble the prosthesis and the production of adapters for patients, were not estimated.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Gargiulo, G. D., Polisiero, Bifulco, Liccardo, A., Cesarelli, M., Romano, D'Apuzzo, & McEwan, A. L. (2013). Design and assessment of a low-cost, electromyographically controlled, prosthetic hand. Medical Devices Evidence and Research, 6, 97. https://doi.org/10.2147/mder.s39604
MLA 9
Gargiulo, Gaetano Dario, et al. “Design and assessment of a low-cost, electromyographically controlled, prosthetic hand.” Medical Devices Evidence and Research, vol. 6, 2013, p. 97. https://doi.org/10.2147/mder.s39604.
Chicago
Gargiulo, Gaetano Dario, Polisiero, Bifulco, Annalisa Liccardo, Mario Cesarelli, Romano, D'Apuzzo, and Alistair Lee McEwan. 2013. “Design and assessment of a low-cost, electromyographically controlled, prosthetic hand.” Medical Devices Evidence and Research 6: 97. https://doi.org/10.2147/mder.s39604.
Harvard
Gargiulo, G. D. et al. (2013) ‘Design and assessment of a low-cost, electromyographically controlled, prosthetic hand’, Medical Devices Evidence and Research, 6, p. 97. doi:10.2147/mder.s39604.
IEEE
G. D. Gargiulo et al., “Design and assessment of a low-cost, electromyographically controlled, prosthetic hand,” Medical Devices Evidence and Research, vol. 6, p. 97, 2013, doi: 10.2147/mder.s39604.
BibTeX
@article{gargiulo2013design,
title = {{Design and assessment of a low-cost, electromyographically controlled, prosthetic hand}},
author = {Gargiulo, Gaetano Dario and Polisiero and Bifulco and Liccardo, Annalisa and Cesarelli, Mario and Romano and D'Apuzzo and McEwan, Alistair Lee},
journal = {Medical Devices Evidence and Research},
year = {2013},
volume = {6},
pages = {97},
doi = {10.2147/mder.s39604},
url = {https://doi.org/10.2147/mder.s39604}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Citations by year
| Year | Citations | Share of the best year |
|---|---|---|
| 2016 | 2 | |
| 2017 | 2 | |
| 2018 | 2 | |
| 2019 | 4 | |
| 2020 | 4 | |
| 2021 | 4 | |
| 2022 | 1 | |
| 2023 | 5 | |
| 2025 | 2 | |
| 2026 | 2 |
Its field-weighted citation impact is 0.85: it has been cited 0.85 times as often as the average work of the same field, type and year (1.00 is the world average).
Topic and keywords
Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- electromyography
- prosthetic hand
- low-cost prosthesis
- amputees
- developing countries
- surface electrodes
- EMG signal processing
- mean absolute value
Work with this paper
Most-cited papers in Engineering
- A Closed‐form Equation for Predicting the Hydraulic Conductivity of Unsaturated SoilsMartinus Th. van Genuchten · Soil Science Society of America Journal · 1980 · 28,197 citations
- An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experimentsW. C. Oliver, George M. Pharr · Journal of materials research/Pratt's guide to venture capital sources · 1992 · 27,379 citations
- Digital communicationsOwen Bishop · Routledge eBooks · 2007 · 24,890 citations
- The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysisNorden Eh Huang, Zhengwei Shen, Steven R. Long and 6 more · Proceedings of the Royal Society A Mathematical Physical and Engineering Sciences · 1998 · 24,008 citations
- Numerical Heat Transfer and Fluid FlowSuhas V. Patankar · CRC Press eBooks · 2018 · 23,491 citations
Questions about this paper
How do I cite this paper in APA style?
Gargiulo, G. D., Polisiero, Bifulco, Liccardo, A., Cesarelli, M., Romano, D'Apuzzo, & McEwan, A. L. (2013). Design and assessment of a low-cost, electromyographically controlled, prosthetic hand. Medical Devices Evidence and Research, 6, 97. https://doi.org/10.2147/mder.s39604
How many times has this paper been cited?
32 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at Medical Devices Evidence and Research: sign in and open the PDF from this page.
Who wrote this paper?
Gaetano Dario Gargiulo, Polisiero, Bifulco, Annalisa Liccardo, Mario Cesarelli, Romano, D'Apuzzo, Alistair Lee McEwan.
What is the DOI of this paper?
10.2147/mder.s39604, permanently at https://doi.org/10.2147/mder.s39604. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.