Conference paper · 2011 · Open access

Design and analysis of an artificial finger joint for anthropomorphic robotic hands

Zhe Xu, Emanuel V. Todorov, Brian Dellon, Yoky Matsuoka

Proceedings - IEEE International Conference on Robotics and Automation/Proceedings, 5096–5102 · Published 1 May 2011 · DOI 10.1109/icra.2011.5979860

Open full textView at the publisherCite this paper

In brief

“Design and analysis of an artificial finger joint for anthropomorphic robotic hands” is a 2011 conference paper by Zhe Xu and 3 co-authors, published in Proceedings - IEEE International Conference on Robotics and Automation/Proceedings. OpenAlex counts 40 citations as of 22 November 2026. It is open access under a public domain licence: the full text is free to read at Zenodo (CERN European Organization for Nuclear Research).

Citations
40
Most cited in
2018 (8)
Field-weighted impact
3.03
References
23
Authors
4

Abstract

In order to further understand what physiological characteristics make a human hand irreplaceable for many dexterous tasks, it is necessary to develop artificial joints that are anatomically correct while sharing similar dynamic features. In this paper, we address the problem of designing a two degree of freedom metacarpophalangeal (MCP) joint of an index finger. The artificial MCP joint is composed of a ball joint, crocheted ligaments, and a silicon rubber sleeve which as a whole provides the functions required of a human finger joint. We quantitatively validate the efficacy of the artificial joint by comparing its dynamic characteristics with that of two human subjects' index fingers by analyzing their impulse response with linear regression. Design parameters of the artificial joint are varied to highlight their effect on the joint's dynamics. A modified, second-order model is fit which accounts for non-linear stiffness and damping, and a higher order model is considered. Good fits are observed both in the human (R2= 0.97) and the artificial joint of the index finger (R2= 0.95). Parameter estimates of stiffness and damping for the artificial joint are found to be similar to those in the literature, indicating our new joint is a good approximation for an index finger's MCP joint.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Xu, Z., Todorov, E. V., Dellon, B., & Matsuoka, Y. (2011). Design and analysis of an artificial finger joint for anthropomorphic robotic hands. Proceedings - IEEE International Conference on Robotics and Automation/Proceedings, 5096–5102. https://doi.org/10.1109/icra.2011.5979860

MLA 9

Xu, Zhe, et al. “Design and analysis of an artificial finger joint for anthropomorphic robotic hands.” Proceedings - IEEE International Conference on Robotics and Automation/Proceedings, 2011, pp. 5096–5102. https://doi.org/10.1109/icra.2011.5979860.

Chicago

Xu, Zhe, Emanuel V. Todorov, Brian Dellon, and Yoky Matsuoka. 2011. “Design and analysis of an artificial finger joint for anthropomorphic robotic hands.” Proceedings - IEEE International Conference on Robotics and Automation/Proceedings: 5096–5102. https://doi.org/10.1109/icra.2011.5979860.

Harvard

Xu, Z. et al. (2011) ‘Design and analysis of an artificial finger joint for anthropomorphic robotic hands’, Proceedings - IEEE International Conference on Robotics and Automation/Proceedings, pp. 5096–5102. doi:10.1109/icra.2011.5979860.

IEEE

Z. Xu, E. V. Todorov, B. Dellon, and Y. Matsuoka, “Design and analysis of an artificial finger joint for anthropomorphic robotic hands,” Proceedings - IEEE International Conference on Robotics and Automation/Proceedings, pp. 5096–5102, 2011, doi: 10.1109/icra.2011.5979860.

BibTeX

@inproceedings{xu2011design,
  title     = {{Design and analysis of an artificial finger joint for anthropomorphic robotic hands}},
  author    = {Xu, Zhe and Todorov, Emanuel V. and Dellon, Brian and Matsuoka, Yoky},
  booktitle = {Proceedings - IEEE International Conference on Robotics and Automation/Proceedings},
  year      = {2011},
  pages     = {5096--5102},
  doi       = {10.1109/icra.2011.5979860},
  url       = {https://doi.org/10.1109/icra.2011.5979860}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
201533
201644
201722
201888
201944
202022
202144
202222
202333
202522

Its field-weighted citation impact is 3.03: it has been cited 3.03 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications

  • metacarpophalangeal joint
  • anthropomorphic robotic hand
  • index finger
  • ball joint
  • joint dynamics
  • impulse response
  • nonlinear stiffness and damping
  • second-order model

Work with this paper

Most-cited papers in Engineering

All highly cited Engineering papers

Questions about this paper

How do I cite this paper in APA style?

Xu, Z., Todorov, E. V., Dellon, B., & Matsuoka, Y. (2011). Design and analysis of an artificial finger joint for anthropomorphic robotic hands. Proceedings - IEEE International Conference on Robotics and Automation/Proceedings, 5096–5102. https://doi.org/10.1109/icra.2011.5979860

How many times has this paper been cited?

40 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Zenodo (CERN European Organization for Nuclear Research): sign in and open the full text from this page.

Who wrote this paper?

Zhe Xu, Emanuel V. Todorov, Brian Dellon, Yoky Matsuoka.

What is the DOI of this paper?

10.1109/icra.2011.5979860, permanently at https://doi.org/10.1109/icra.2011.5979860. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.