Journal article · 2026 · Open access

Deep learning–based detection of the second mesiobuccal canal in maxillary first molars using cone-beam computed tomography

Jiao Lin, Jialing Liu, Yuxin Jiang, Yang Liu, Bixin Wen, Shihao Li, Chenglong Li

BMC Oral Health, 26(1) · Published 9 April 2026 · DOI 10.1186/s12903-026-08207-8

Open full textCite this paper

In brief

“Deep learning–based detection of the second mesiobuccal canal in maxillary first molars using cone-beam computed tomography” is a 2026 journal article by Jiao Lin and 6 co-authors, published in BMC Oral Health. OpenAlex counts 1 citations as of 18 November 2026. It is open access under a CC BY-NC-ND licence: the full text is free to read at BMC Oral Health.

Citations
1
Most cited in
2026 (1)
Field-weighted impact
3.65
References
27
Authors
7

Abstract

BACKGROUND: Missed detection of the second mesiobuccal canal (MB2) in maxillary first molars is a recognized contributor to endodontic failure. Although cone-beam computed tomography (CBCT) enhances three-dimensional visualization of root canal anatomy, image interpretation remains observer-dependent and variable. OBJECTIVE: To develop and validate a deep learning (DL) model for automated detection of MB2 canals on CBCT images and to evaluate its impact on the diagnostic performance of junior dentists. METHODS: CBCT scans from 1,022 patients were annotated by expert consensus using comprehensive volumetric evaluation. A two-stage DL framework—region-of-interest localization using a modified VGG16 network followed by classification with a ConvNeXt–Transformer architecture-was trained on 1,944 ROIs and evaluated on an independent test set of 100 ROIs (50 MB2-positive, 50 MB2-negative). Three junior dentists assessed the test set with and without DL assistance. RESULTS: The proposed model achieved a sensitivity of 0.84, specificity of 0.86, positive predictive value of 0.86, negative predictive value of 0.84, F1-score of 0.85, and an area under the receiver operating characteristic curve (AUC) of 0.85, outperforming benchmark CNN architectures. DL assistance increased junior dentists’ F1-scores (0.78–0.82 manually vs. 0.82–0.88 with assistance) and improved inter-reader agreement (Fleiss’ κ: 0.730 to 0.880). CONCLUSIONS: The proposed DL framework demonstrated balanced diagnostic performance for MB2 detection and enhanced diagnostic consistency among junior clinicians. Deep learning may serve as an adjunctive decision-support tool in endodontic imaging and education. Further multicenter validation is warranted to establish generalizability and clinical applicability.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Lin, J., Liu, J., Jiang, Y., Liu, Y., Wen, B., Li, S., & Li, C. (2026). Deep learning–based detection of the second mesiobuccal canal in maxillary first molars using cone-beam computed tomography. BMC Oral Health, 26(1). https://doi.org/10.1186/s12903-026-08207-8

MLA 9

Lin, Jiao, et al. “Deep learning–based detection of the second mesiobuccal canal in maxillary first molars using cone-beam computed tomography.” BMC Oral Health, vol. 26, no. 1, 2026. https://doi.org/10.1186/s12903-026-08207-8.

Chicago

Lin, Jiao, Jialing Liu, Yuxin Jiang, Yang Liu, Bixin Wen, Shihao Li, and Chenglong Li. 2026. “Deep learning–based detection of the second mesiobuccal canal in maxillary first molars using cone-beam computed tomography.” BMC Oral Health 26 (1). https://doi.org/10.1186/s12903-026-08207-8.

Harvard

Lin, J. et al. (2026) ‘Deep learning–based detection of the second mesiobuccal canal in maxillary first molars using cone-beam computed tomography’, BMC Oral Health, 26(1). doi:10.1186/s12903-026-08207-8.

IEEE

J. Lin et al., “Deep learning–based detection of the second mesiobuccal canal in maxillary first molars using cone-beam computed tomography,” BMC Oral Health, vol. 26, no. 1, 2026, doi: 10.1186/s12903-026-08207-8.

BibTeX

@article{lin2026deep,
  title     = {{Deep learning–based detection of the second mesiobuccal canal in maxillary first molars using cone-beam computed tomography}},
  author    = {Lin, Jiao and Liu, Jialing and Jiang, Yuxin and Liu, Yang and Wen, Bixin and Li, Shihao and Li, Chenglong},
  journal   = {BMC Oral Health},
  year      = {2026},
  volume    = {26},
  number    = {1},
  doi       = {10.1186/s12903-026-08207-8},
  url       = {https://doi.org/10.1186/s12903-026-08207-8}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Health Sciences › Dentistry › Oral Surgery › Dental Radiography and Imaging

  • second mesiobuccal canal
  • maxillary first molar
  • root canal anatomy
  • canal detection
  • cone-beam computed tomography
  • deep learning
  • endodontic diagnosis
  • diagnostic accuracy

Work with this paper

Most-cited papers in Dentistry

All highly cited Dentistry papers

Questions about this paper

How do I cite this paper in APA style?

Lin, J., Liu, J., Jiang, Y., Liu, Y., Wen, B., Li, S., & Li, C. (2026). Deep learning–based detection of the second mesiobuccal canal in maxillary first molars using cone-beam computed tomography. BMC Oral Health, 26(1). https://doi.org/10.1186/s12903-026-08207-8

How many times has this paper been cited?

1 times, according to OpenAlex on 18 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at BMC Oral Health: sign in and open the full text from this page.

Who wrote this paper?

Jiao Lin, Jialing Liu, Yuxin Jiang, Yang Liu, Bixin Wen, Shihao Li, Chenglong Li.

What is the DOI of this paper?

10.1186/s12903-026-08207-8, permanently at https://doi.org/10.1186/s12903-026-08207-8. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 18 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.