Journal article · 2020 · Open access

Data-Driven Shape Sensing of a Surgical Continuum Manipulator Using an Uncalibrated Fiber Bragg Grating Sensor

Shahriar Sefati, Cong Gao, Iulian Ioan Iordachita, Russell H. Taylor, Mehran Armand

IEEE Sensors Journal, 21(3), 3066–3076 · Published 1 October 2020 · DOI 10.1109/jsen.2020.3028208

Open full textView at the publisherCite this paper

In brief

“Data-Driven Shape Sensing of a Surgical Continuum Manipulator Using an Uncalibrated Fiber Bragg Grating Sensor” is a 2020 journal article by Shahriar Sefati and 4 co-authors, published in IEEE Sensors Journal. OpenAlex counts 86 citations as of 26 November 2026, which puts it in the top 2% of works published in 2020 by citations. It is open access: the full text is free to read at PubMed Central.

Citations
86
Most cited in
2025 (19)
Field-weighted impact
2.25
References
30
Authors
5

Abstract

This article proposes a data-driven learning-based approach for shape sensing and Distal-end Position Estimation (DPE) of a surgical Continuum Manipulator (CM) in constrained environments using Fiber Bragg Grating (FBG) sensors. The proposed approach uses only the sensory data from an unmodeled uncalibrated sensor embedded in the CM to estimate the shape and DPE. It serves as an alternate to the conventional mechanics-based sensor-model-dependent approach which relies on several sensor and CM geometrical assumptions. Unlike the conventional approach where the shape is reconstructed from proximal to distal end of the device, we propose a reversed approach where the distal-end position is estimated first and given this information, shape is then reconstructed from distal to proximal end. The proposed methodology yields more accurate DPE by avoiding accumulation of integration errors in conventional approaches. We study three data-driven models, namely a linear regression model, a Deep Neural Network (DNN), and a Temporal Neural Network (TNN) and compare DPE and shape reconstruction results. Additionally, we test both approaches (data-driven and model-dependent) against internal and external disturbances to the CM and its environment such as incorporation of flexible medical instruments into the CM and contacts with obstacles in taskspace. Using the data-driven (DNN) and model-dependent approaches, the following max absolute errors are observed for DPE: 0.78 mm and 2.45 mm in free bending motion, 0.11 mm and 3.20 mm with flexible instruments, and 1.22 mm and 3.19 mm with taskspace obstacles, indicating superior performance of the proposed data-driven approach compared to the conventional approaches.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Sefati, S., Gao, C., Iordachita, I. I., Taylor, R. H., & Armand, M. (2020). Data-Driven Shape Sensing of a Surgical Continuum Manipulator Using an Uncalibrated Fiber Bragg Grating Sensor. IEEE Sensors Journal, 21(3), 3066–3076. https://doi.org/10.1109/jsen.2020.3028208

MLA 9

Sefati, Shahriar, et al. “Data-Driven Shape Sensing of a Surgical Continuum Manipulator Using an Uncalibrated Fiber Bragg Grating Sensor.” IEEE Sensors Journal, vol. 21, no. 3, 2020, pp. 3066–3076. https://doi.org/10.1109/jsen.2020.3028208.

Chicago

Sefati, Shahriar, Cong Gao, Iulian Ioan Iordachita, Russell H. Taylor, and Mehran Armand. 2020. “Data-Driven Shape Sensing of a Surgical Continuum Manipulator Using an Uncalibrated Fiber Bragg Grating Sensor.” IEEE Sensors Journal 21 (3): 3066–3076. https://doi.org/10.1109/jsen.2020.3028208.

Harvard

Sefati, S. et al. (2020) ‘Data-Driven Shape Sensing of a Surgical Continuum Manipulator Using an Uncalibrated Fiber Bragg Grating Sensor’, IEEE Sensors Journal, 21(3), pp. 3066–3076. doi:10.1109/jsen.2020.3028208.

IEEE

S. Sefati, C. Gao, I. I. Iordachita, R. H. Taylor, and M. Armand, “Data-Driven Shape Sensing of a Surgical Continuum Manipulator Using an Uncalibrated Fiber Bragg Grating Sensor,” IEEE Sensors Journal, vol. 21, no. 3, pp. 3066–3076, 2020, doi: 10.1109/jsen.2020.3028208.

BibTeX

@article{sefati2020data,
  title     = {{Data-Driven Shape Sensing of a Surgical Continuum Manipulator Using an Uncalibrated Fiber Bragg Grating Sensor}},
  author    = {Sefati, Shahriar and Gao, Cong and Iordachita, Iulian Ioan and Taylor, Russell H. and Armand, Mehran},
  journal   = {IEEE Sensors Journal},
  year      = {2020},
  volume    = {21},
  number    = {3},
  pages     = {3066--3076},
  doi       = {10.1109/jsen.2020.3028208},
  url       = {https://doi.org/10.1109/jsen.2020.3028208}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
202177
20221111
20231616
20241616
20251919
20261717

Its field-weighted citation impact is 2.25: it has been cited 2.25 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications

  • shape sensing
  • fiber Bragg grating sensors
  • data-driven modeling
  • deep neural network
  • temporal neural networks
  • linear regression
  • obstacle contact
  • constrained environments

Work with this paper

Most-cited papers in Engineering

All highly cited Engineering papers

Questions about this paper

How do I cite this paper in APA style?

Sefati, S., Gao, C., Iordachita, I. I., Taylor, R. H., & Armand, M. (2020). Data-Driven Shape Sensing of a Surgical Continuum Manipulator Using an Uncalibrated Fiber Bragg Grating Sensor. IEEE Sensors Journal, 21(3), 3066–3076. https://doi.org/10.1109/jsen.2020.3028208

How many times has this paper been cited?

86 times, according to OpenAlex on 26 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at PubMed Central: sign in and open the full text from this page.

Who wrote this paper?

Shahriar Sefati, Cong Gao, Iulian Ioan Iordachita, Russell H. Taylor, Mehran Armand.

What is the DOI of this paper?

10.1109/jsen.2020.3028208, permanently at https://doi.org/10.1109/jsen.2020.3028208. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 26 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.