“Cutaneous Feedback of Fingertip Deformation and Vibration for Palpation in Robotic Surgery” is a 2015 journal article by Claudio Pacchierotti and 2 co-authors, published in IEEE Transactions on Biomedical Engineering. OpenAlex counts 263 citations as of 22 November 2026, which puts it in the top 2% of works published in 2015 by citations. It is open access: the full text is free to read at HAL.

Citations
263
Most cited in
2018 (37)
Field-weighted impact
23.16
References
45
Authors
3

Abstract

Despite its expected clinical benefits, current teleoperated surgical robots do not provide the surgeon with haptic feedback largely because grounded forces can destabilize the system's closed-loop controller. This paper presents an alternative approach that enables the surgeon to feel fingertip contact deformations and vibrations while guaranteeing the teleoperator's stability. We implemented our cutaneous feedback solution on an Intuitive Surgical da Vinci Standard robot by mounting a SynTouch BioTac tactile sensor to the distal end of a surgical instrument and a custom cutaneous display to the corresponding master controller. As the user probes the remote environment, the contact deformations, dc pressure, and ac pressure (vibrations) sensed by the BioTac are directly mapped to input commands for the cutaneous device's motors using a model-free algorithm based on look-up tables. The cutaneous display continually moves, tilts, and vibrates a flat plate at the operator's fingertip to optimally reproduce the tactile sensations experienced by the BioTac. We tested the proposed approach by having eighteen subjects use the augmented da Vinci robot to palpate a heart model with no haptic feedback, only deformation feedback, and deformation plus vibration feedback. Fingertip deformation feedback significantly improved palpation performance by reducing the task completion time, the pressure exerted on the heart model, and the subject's absolute error in detecting the orientation of the embedded plastic stick. Vibration feedback significantly improved palpation performance only for the seven subjects who dragged the BioTac across the model, rather than pressing straight into it.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Pacchierotti, C., Prattichizzo, D., & Kuchenbecker, K. J. (2015). Cutaneous Feedback of Fingertip Deformation and Vibration for Palpation in Robotic Surgery. IEEE Transactions on Biomedical Engineering, 63(2), 278–287. https://doi.org/10.1109/tbme.2015.2455932

MLA 9

Pacchierotti, Claudio, et al. “Cutaneous Feedback of Fingertip Deformation and Vibration for Palpation in Robotic Surgery.” IEEE Transactions on Biomedical Engineering, vol. 63, no. 2, 2015, pp. 278–287. https://doi.org/10.1109/tbme.2015.2455932.

Chicago

Pacchierotti, Claudio, Domenico Prattichizzo, and Katherine J. Kuchenbecker. 2015. “Cutaneous Feedback of Fingertip Deformation and Vibration for Palpation in Robotic Surgery.” IEEE Transactions on Biomedical Engineering 63 (2): 278–287. https://doi.org/10.1109/tbme.2015.2455932.

Harvard

Pacchierotti, C., Prattichizzo, D. and Kuchenbecker, K. J. (2015) ‘Cutaneous Feedback of Fingertip Deformation and Vibration for Palpation in Robotic Surgery’, IEEE Transactions on Biomedical Engineering, 63(2), pp. 278–287. doi:10.1109/tbme.2015.2455932.

IEEE

C. Pacchierotti, D. Prattichizzo, and K. J. Kuchenbecker, “Cutaneous Feedback of Fingertip Deformation and Vibration for Palpation in Robotic Surgery,” IEEE Transactions on Biomedical Engineering, vol. 63, no. 2, pp. 278–287, 2015, doi: 10.1109/tbme.2015.2455932.

BibTeX

@article{pacchierotti2015cutaneous,
  title     = {{Cutaneous Feedback of Fingertip Deformation and Vibration for Palpation in Robotic Surgery}},
  author    = {Pacchierotti, Claudio and Prattichizzo, Domenico and Kuchenbecker, Katherine J.},
  journal   = {IEEE Transactions on Biomedical Engineering},
  year      = {2015},
  volume    = {63},
  number    = {2},
  pages     = {278--287},
  doi       = {10.1109/tbme.2015.2455932},
  url       = {https://doi.org/10.1109/tbme.2015.2455932}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
20172020
20183737
20191515
20203030
20211919
20221919
20232222
20243535
20252121
20262222

Its field-weighted citation impact is 23.16: it has been cited 23.16 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems

  • cutaneous feedback
  • haptic feedback
  • robotic surgery
  • palpation
  • fingertip deformation
  • vibration feedback
  • da Vinci surgical system
  • teleoperation stability

Work with this paper

Most-cited papers in Engineering

All highly cited Engineering papers

Questions about this paper

How do I cite this paper in APA style?

Pacchierotti, C., Prattichizzo, D., & Kuchenbecker, K. J. (2015). Cutaneous Feedback of Fingertip Deformation and Vibration for Palpation in Robotic Surgery. IEEE Transactions on Biomedical Engineering, 63(2), 278–287. https://doi.org/10.1109/tbme.2015.2455932

How many times has this paper been cited?

263 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at HAL: sign in and open the full text from this page.

Who wrote this paper?

Claudio Pacchierotti, Domenico Prattichizzo, Katherine J. Kuchenbecker.

What is the DOI of this paper?

10.1109/tbme.2015.2455932, permanently at https://doi.org/10.1109/tbme.2015.2455932. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.