Journal article · 2017 · Open access

Continuum Reconfigurable Parallel Robots for Surgery: Shape Sensing and State Estimation With Uncertainty

Patrick L. Anderson, Arthur W. Mahoney, Robert James Webster III

IEEE Robotics and Automation Letters, 2(3), 1617–1624 · Published 6 March 2017 · DOI 10.1109/lra.2017.2678606

Open full textView at the publisherCite this paper

In brief

“Continuum Reconfigurable Parallel Robots for Surgery: Shape Sensing and State Estimation With Uncertainty” is a 2017 journal article by Patrick L. Anderson and 2 co-authors, published in IEEE Robotics and Automation Letters. OpenAlex counts 64 citations as of 26 November 2026, which puts it in the top 8% of works published in 2017 by citations. It is open access: the full text is free to read at Europe PMC (PubMed Central).

Citations
64
Most cited in
2026 (11)
Field-weighted impact
1.58
References
24
Authors
3

Abstract

This paper examines shape sensing for a new class of surgical robot that consists of parallel flexible structures that can be reconfigured inside the human body. Known as CRISP robots, these devices provide access to the human body through needle-sized entry points, yet can be configured into truss-like structures capable of dexterous movement and large force application. They can also be reconfigured as needed during a surgical procedure. Since CRISP robots are elastic, they will deform when subjected to external forces or other perturbations. In this paper, we explore how to combine sensor information with mechanics-based models for CRISP robots to estimate their shapes under applied loads. The end result is a shape sensing framework for CRISP robots that will enable future research on control under applied loads, autonomous motion, force sensing, and other robot behaviors.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Anderson, P. L., Mahoney, A. W., & III, R. J. W. (2017). Continuum Reconfigurable Parallel Robots for Surgery: Shape Sensing and State Estimation With Uncertainty. IEEE Robotics and Automation Letters, 2(3), 1617–1624. https://doi.org/10.1109/lra.2017.2678606

MLA 9

Anderson, Patrick L., et al. “Continuum Reconfigurable Parallel Robots for Surgery: Shape Sensing and State Estimation With Uncertainty.” IEEE Robotics and Automation Letters, vol. 2, no. 3, 2017, pp. 1617–1624. https://doi.org/10.1109/lra.2017.2678606.

Chicago

Anderson, Patrick L., Arthur W. Mahoney, and Robert James Webster III. 2017. “Continuum Reconfigurable Parallel Robots for Surgery: Shape Sensing and State Estimation With Uncertainty.” IEEE Robotics and Automation Letters 2 (3): 1617–1624. https://doi.org/10.1109/lra.2017.2678606.

Harvard

Anderson, P. L., Mahoney, A. W. and III, R. J. W. (2017) ‘Continuum Reconfigurable Parallel Robots for Surgery: Shape Sensing and State Estimation With Uncertainty’, IEEE Robotics and Automation Letters, 2(3), pp. 1617–1624. doi:10.1109/lra.2017.2678606.

IEEE

P. L. Anderson, A. W. Mahoney, and R. J. W. III, “Continuum Reconfigurable Parallel Robots for Surgery: Shape Sensing and State Estimation With Uncertainty,” IEEE Robotics and Automation Letters, vol. 2, no. 3, pp. 1617–1624, 2017, doi: 10.1109/lra.2017.2678606.

BibTeX

@article{anderson2017continuum,
  title     = {{Continuum Reconfigurable Parallel Robots for Surgery: Shape Sensing and State Estimation With Uncertainty}},
  author    = {Anderson, Patrick L. and Mahoney, Arthur W. and III, Robert James Webster},
  journal   = {IEEE Robotics and Automation Letters},
  year      = {2017},
  volume    = {2},
  number    = {3},
  pages     = {1617--1624},
  doi       = {10.1109/lra.2017.2678606},
  url       = {https://doi.org/10.1109/lra.2017.2678606}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
201722
201855
201933
202066
202199
202255
202366
202488
202599
20261111

Its field-weighted citation impact is 1.58: it has been cited 1.58 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications

  • continuum robots
  • shape sensing
  • state estimation
  • uncertainty
  • flexible structures
  • truss-like structures
  • elastic deformation
  • sensor fusion

Work with this paper

Most-cited papers in Engineering

All highly cited Engineering papers

Questions about this paper

How do I cite this paper in APA style?

Anderson, P. L., Mahoney, A. W., & III, R. J. W. (2017). Continuum Reconfigurable Parallel Robots for Surgery: Shape Sensing and State Estimation With Uncertainty. IEEE Robotics and Automation Letters, 2(3), 1617–1624. https://doi.org/10.1109/lra.2017.2678606

How many times has this paper been cited?

64 times, according to OpenAlex on 26 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Europe PMC (PubMed Central): sign in and open the full text from this page.

Who wrote this paper?

Patrick L. Anderson, Arthur W. Mahoney, Robert James Webster III.

What is the DOI of this paper?

10.1109/lra.2017.2678606, permanently at https://doi.org/10.1109/lra.2017.2678606. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 26 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.